Studies on the stability of the clinical electro-oculogram.

N Timmins1, M F Marmor.   

Abstract

The electro-oculogram is variable as a clinical test, but the recording technique has not been standardized, and differences in the protocols for adaptation and stimulation among laboratories may contribute to the variability. To analyze some of these factors, we performed more than 100 electro-oculograms on a single subject under different conditions. Both the Arden ratio and the ratio of light peak amplitude to a stable dark-adapted baseline were independent of pupillary dilation but linearly related to retinal illumination measured in trolands. Between 3.0 and 4.0 log trolands, the values began to level off, but they were difficult to interpret because of subject discomfort above 3.5 log trolands. The Arden ratios were influenced by preadaptation light levels and were roughly 20% higher above 90 cd/m2 than below 45 cd/m2. There was a circadian rhythm in dark trough, baseline and light peak values, but the composite Arden ratio and light peak/baseline ratio showed little circadian effect. The light peak/baseline ratios were slightly more stable than the Arden ratios; the variability (defined as [standard deviation x 100]/mean) was 6.6% and 12.5%, respectively. Our results suggest that stimulus intensities for clinical electro-oculographic testing should be between 3.0 and 3.5 log trolands; pupil dilation is optional. This translates into light levels of 141-447 cd/m2 for a 3-mm pupil and 20-63 cd/m2 for an 8-mm pupil. The reduction in variability and independence from preadaptation achieved by using the light peak/baseline ratio instead of the Arden ratio must be weighed against the time required to achieve a stable dark baseline.

Entities:  

Mesh:

Year:  1992        PMID: 1468346     DOI: 10.1007/bf00156005

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  15 in total

1.  Corneo-fundal potential variations during light and dark adaptation.

Authors:  C KRIS
Journal:  Nature       Date:  1958-10-11       Impact factor: 49.962

2.  [Spontaneous & experimental changes of the steady polarity potential of the human eye].

Authors:  H KOLDER
Journal:  Pflugers Arch Gesamte Physiol Menschen Tiere       Date:  1959

3.  Modification of the amplitude of the human electro-oculogram by light and dark adaptation.

Authors:  J FRANCOIS; G VERRIEST; A DE ROUCK
Journal:  Br J Ophthalmol       Date:  1955-07       Impact factor: 4.638

4.  The corneofundal potential and the electrooculogram. Aspects of normal physiology and variability.

Authors:  E Krogh
Journal:  Acta Ophthalmol Suppl       Date:  1979

5.  Light peak to dark trough ratio in clinical electro-oculography: influence of dark oscillations on the following light peak.

Authors:  A Thaler; P Heilig; J Gordesch
Journal:  Bibl Ophthalmol       Date:  1976

6.  [Variations in "resting potential" of the human eye following changes in luminance. Inter- and intraindividual standard deviation, relation to the magnitude of the luminance steps (author's transl)].

Authors:  R Täumer; G Mackensen; H Hartmann; U Moser; R Stehle; W Werner; D Wolf
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1973-12-18

7.  [Influence of preadaptation on the potential course of EOG].

Authors:  W Müller; H Körber; H J Körber
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1970-10-09

8.  [The illumination phase of the electrooculogram at various levels of illumination].

Authors:  W Müller; E Haase; H Janzen; W Pohl; E Mirsch; G Thieme
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1971

Review 9.  Electro-oculography.

Authors:  H E Kolder
Journal:  Ophthalmologica       Date:  1974       Impact factor: 3.250

10.  The electrooculogram and its interindividual and intraindividual variability.

Authors:  A Zonneveldt; G van Lith
Journal:  Ophthalmologica       Date:  1980       Impact factor: 3.250

View more
  4 in total

1.  Alcohol- and light-induced electro-oculographic responses: variability and clinical utility.

Authors:  Michael F Marmor; Kathy H C Wu
Journal:  Doc Ophthalmol       Date:  2005 Mar-May       Impact factor: 2.379

Review 2.  A meta-analysis of clinical electro-oculography values.

Authors:  Paul A Constable; David Ngo; Stephen Quinn; Dorothy A Thompson
Journal:  Doc Ophthalmol       Date:  2017-10-10       Impact factor: 2.379

3.  Real-Time Control of a Video Game Using Eye Movements and Two Temporal EEG Sensors.

Authors:  Abdelkader Nasreddine Belkacem; Supat Saetia; Kalanyu Zintus-art; Duk Shin; Hiroyuki Kambara; Natsue Yoshimura; Nasreddine Berrached; Yasuharu Koike
Journal:  Comput Intell Neurosci       Date:  2015-11-15

4.  Affine transform to reform pixel coordinates of EOG signals for controlling robot manipulators using gaze motions.

Authors:  Muhammad Ilhamdi Rusydi; Minoru Sasaki; Satoshi Ito
Journal:  Sensors (Basel)       Date:  2014-06-10       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.