[Scatter correction in myocardial thallium SPECT: needs for optimization of energy window settings in the energy window-based scatter correction techniques].

Y Narita1, H Iida.   

Abstract

Accuracy and limitation of energy-window based scatter correction techniques have been evaluated for myocardial 201Tl SPECT by means of Monte Carlo simulation. In particular, projection view-dependency of energy distribution of the scattered photons was evaluated. Two geometrical configurations were simulated: namely a homogeneous cylindrical radioactivity located asymmetrically in a homogeneous cylindrical phantom, and a homogeneous ring radioactivity positioned at the myocardial region of a human thorax phantom. Energy spectra were recorded for each projection, and accuracy of the triple-energy window (TEW) method was then evaluation for both phantoms. The energy distribution of the scattered photons was apparently dependent on the projection view. TEW also demonstrated systematic overcorrection for the scatter because of multiple photo peaks around 80 KeV, and more importantly, the error was highly dependent on the projection view. The error reached to 35-38% for the view that is the closest to the 201Tl radioactivity (anterior view in case of the myocardial ring phantom), and was approximately 20% in the opposite view. This view-dependency of the error remained for other energy window settings, and was found to cause significant artifact in the reconstructed myocardial images, typically causing a defect in the anterior myocardial wall. Thus, this study demonstrated the need for optimizing the window settings for each projection view in all energy window-based scatter correction methods.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10213975

Source DB:  PubMed          Journal:  Kaku Igaku        ISSN: 0022-7854


  3 in total

1.  Collimator choice in cardiac SPECT with I-123-labeled tracers.

Authors:  Yusuke Inoue; Ichiro Shirouzu; Toru Machida; Yasunori Yoshizawa; Fumihide Akita; Manabu Minami; Kuni Ohtomo
Journal:  J Nucl Cardiol       Date:  2004 Jul-Aug       Impact factor: 5.952

2.  Effect of collimator choice on quantitative assessment of cardiac iodine 123 MIBG uptake.

Authors:  Yusuke Inoue; Akira Suzuki; Ichiro Shirouzu; Toru Machida; Yasunori Yoshizawa; Fumihide Akita; Satoshi Ohnishi; Kohki Yoshikawa; Kuni Ohtomo
Journal:  J Nucl Cardiol       Date:  2003 Nov-Dec       Impact factor: 5.952

3.  Quantitative assessment of rest and acetazolamide CBF using quantitative SPECT reconstruction and sequential administration of (123)I-iodoamphetamine: comparison among data acquired at three institutions.

Authors:  Miho Yamauchi; Etsuko Imabayashi; Hiroshi Matsuda; Jyoji Nakagawara; Masaaki Takahashi; Eku Shimosegawa; Jun Hatazawa; Michiyasu Suzuki; Hideyuki Iwanaga; Kenji Fukuda; Koji Iihara; Hidehiro Iida
Journal:  Ann Nucl Med       Date:  2014-07-08       Impact factor: 2.668

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.