Literature DB >> 1466321

Classification of morphologic effects of percutaneous transluminal coronary angioplasty assessed by intravascular ultrasound.

T C Gerber1, R Erbel, G Görge, J Ge, H J Rupprecht, J Meyer.   

Abstract

The aim of this study was the assessment and classification of the morphologic effects of percutaneous transluminal angioplasty (PTCA) by intravascular ultrasound (IU). Fifty-eight patients were examined immediately after PTCA with a 4.8Fr, 20 MHz rotational tip IU system. In 10 patients (17%), IU images could not be analyzed due to failure of the imaging system or poor image quality. In 48 patients (83%; 40 men and 8 women, aged 55 +/- 9 years), IU images of 48 PTCA segments, as well as 41 distal and 44 proximal sites, were analyzed. The left anterior descending artery was studied in 30 patients, the right coronary artery in 17 and the left main coronary artery in 1. Calcium was present in 32 of 48 PTCA segments (67%). Plaque morphology was concentric in 18 patients (38%) and eccentric in 30 (62%). Seven distinct morphologic patterns were observed. In concentric plaques, plaque compression without significant wall alterations (type 1) was found in 2 patients (4%), superficial tears within the plaque (type 2) in 1 (2%) and deep tears (type 3) in 8 (17%). Deep tearing associated with submedial or subintimal dissection (type 4) was found in 2 patients (4%). Dissection between plaque and vessel wall without noticeable intimal tearing (type 5) was the most common morphology (n = 15; 31%) and occurred in concentric and eccentric plaques. In eccentric plaques, no significant tearing of the plaque (type 6) was found in 6 patients (13%), and tearing of the plaque close to its base with dissection (type 7) in 14 (29%).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1992        PMID: 1466321     DOI: 10.1016/0002-9149(92)90455-8

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  8 in total

1.  Improvement of coronary morphology and blood flow after stenting. Assessment by intravascular ultrasound and intracoronary Doppler.

Authors:  J Ge; R Erbel; J Zamorano; M Haude; P Kearney; G Görge; J Meyer
Journal:  Int J Card Imaging       Date:  1995-06

2.  In vitro examination of the coronary artery wall after balloon angioplasty using intracoronary ultrasound.

Authors:  T Voigtländer; H J Rupprecht; M Britten; P Stähr; B Nowak; M Otto; C J Kirkpatrick; R Brennecke; J Meyer
Journal:  Int J Card Imaging       Date:  1998-02

3.  Additional luminal area gain by intravascular ultrasound guidance after coronary stent implantation with high inflation pressure.

Authors:  G S Werner; J Diedrich; S Schünemann; O Gastmann; M Ferrari; A B Buchwald; H R Figulla; H Kreuzer
Journal:  Int J Card Imaging       Date:  1997-08

Review 4.  Intracoronary ultrasound: current state of the art.

Authors:  P P Kearney; I R Starkey; G R Sutherland
Journal:  Br Heart J       Date:  1995-05

5.  Morphology of chronic coronary occlusions and response to interventional therapy--a study by intracoronary ultrasound.

Authors:  G S Werner; J Diedrich; A J Morguet; A B Buchwald; H Kreuzer
Journal:  Int J Card Imaging       Date:  1997-12

Review 6.  Coronary microembolization--its role in acute coronary syndromes and interventions.

Authors:  R Erbel; G Heusch
Journal:  Herz       Date:  1999-11       Impact factor: 1.443

7.  Quantitative assessment of peripheral and coronary artery lesions before and after balloon angioplasty: a comparison of intravascular ultrasound and angiography.

Authors:  M Schartl; W Bocksch; T Linderer; S Beckmann; S Dreysse
Journal:  Heart Vessels       Date:  1994       Impact factor: 2.037

Review 8.  Intracoronary ultrasound.

Authors:  C Hammond; J P Causer; R A Perry
Journal:  Postgrad Med J       Date:  1998-08       Impact factor: 2.401

  8 in total