Literature DB >> 9559380

In vitro examination of the coronary artery wall after balloon angioplasty using intracoronary ultrasound.

T Voigtländer1, H J Rupprecht, M Britten, P Stähr, B Nowak, M Otto, C J Kirkpatrick, R Brennecke, J Meyer.   

Abstract

After autopsy 12 human coronary arteries were investigated by intracoronary ultrasound in order to measure the vessel wall dimensions and to detect damage on the vessel wall architecture after balloon angioplasty. Histology revealed artherosclerosis in 11/12 arteries. A total of 41 representative coronary segments were selected for further off-line ultrasound and histological analysis. Intracoronary ultrasound and histological measurements of the vessel wall thickness after balloon dilatation demonstrated a good correlation between the maximum thickness of the intima (histology 0.62 mm vs. intracoronary ultrasound 0.65 mm, r = 0.87) and the intima-media complex (0.80 mm vs. 0.83 mm, r = 0.87), in contrast to a weak one between the minimum thickness (r = 0.46 and r = 0.37). A total of 21 cases of damage occurred during angioplasty; intracoronary ultrasound detected 17. Further analysis showed that it imaged 10 of 11 cases of damage involving more than 30 degrees of the vessel circumference and 7 of 10 cases of damage involving less than 30 degrees of the vessel circumference. After balloon angioplasty of diseased coronary arteries, intracoronary ultrasound is therefore reliable in measuring the maximum wall thickness and in imaging damage involving more than 30 degrees of the vessel wall circumference.

Entities:  

Mesh:

Year:  1998        PMID: 9559380     DOI: 10.1023/a:1005846615032

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  14 in total

1.  Arterial responses to balloon coronary angioplasty: an intravascular ultrasound study.

Authors:  B N Potkin; G Keren; G S Mintz; P C Douek; A D Pichard; L F Satler; K M Kent; M B Leon
Journal:  J Am Coll Cardiol       Date:  1992-10       Impact factor: 24.094

2.  Intravascular ultrasound cross-sectional arterial imaging before and after balloon angioplasty in vitro.

Authors:  J M Tobis; J A Mallery; J Gessert; J Griffith; D Mahon; M Bessen; M Moriuchi; L McLeay; M McRae; W L Henry
Journal:  Circulation       Date:  1989-10       Impact factor: 29.690

3.  Real-time intravascular ultrasonic imaging before and after balloon angioplasty.

Authors:  E J Gussenhoven; S H The; P Gerritsen; H van Urk; W G Li; F C van Egmond; J R Roelandt; C T Lancée; N Bom
Journal:  J Clin Ultrasound       Date:  1991-06       Impact factor: 0.910

4.  Intravascular ultrasound imaging: in vitro validation and pathologic correlation.

Authors:  R A Nishimura; W D Edwards; C A Warnes; G S Reeder; D R Holmes; A J Tajik; P G Yock
Journal:  J Am Coll Cardiol       Date:  1990-07       Impact factor: 24.094

5.  Intravascular ultrasound imaging of arterial wall architecture.

Authors:  J Ge; R Erbel; G Görge; T Gerber; R Brennecke; I Seidel; T Reichert; J Meyer
Journal:  Echocardiography       Date:  1992-09       Impact factor: 1.724

6.  Pathology of transluminal balloon angioplasty used in the treatment of coronary heart disease.

Authors:  B F Waller
Journal:  Hum Pathol       Date:  1987-05       Impact factor: 3.466

7.  Intravascular ultrasound imaging of coronary arteries. Is three layers the norm?

Authors:  P J Fitzgerald; F G St Goar; A J Connolly; F J Pinto; M E Billingham; R L Popp; P G Yock
Journal:  Circulation       Date:  1992-07       Impact factor: 29.690

8.  Morphological effects of coronary balloon angioplasty in vivo assessed by intravascular ultrasound imaging.

Authors:  J Honye; D J Mahon; A Jain; C J White; S R Ramee; J B Wallis; A al-Zarka; J M Tobis
Journal:  Circulation       Date:  1992-03       Impact factor: 29.690

9.  Comparison of intravascular ultrasonic findings after coronary balloon angioplasty evaluated in vitro with histology.

Authors:  A van der Lugt; E J Gussenhoven; T Stijnen; M van Strijen; E van Driel; F C van Egmond; R J van Suylen; H van Urk
Journal:  Am J Cardiol       Date:  1995-10-01       Impact factor: 2.778

10.  Differences in the morphology of unstable and stable coronary lesions and their impact on the mechanisms of angioplasty. An in vivo study with intravascular ultrasound.

Authors:  P Kearney; R Erbel; H J Rupprecht; J Ge; L Koch; T Voigtländer; P Stähr; G Görge; J Meyer
Journal:  Eur Heart J       Date:  1996-05       Impact factor: 29.983

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.