Literature DB >> 14647945

Nanoscale proteomics.

Y Shen1, N Tolić, C Masselon, L Pasa-Tolić, D G Camp, M S Lipton, G A Anderson, R D Smith.   

Abstract

Efforts to develop a liquid chromatography (LC)/mass spectrometry (MS) technology for ultra-sensitive proteomics studies (i.e., nanoscale proteomics) are described. The approach combines high-efficiency nanoscale LC (separation peak capacity of approximately 10(3); 15-microm-i.d. packed capillaries with flow rates of 20 nL min(-1), the optimal separation linear velocity) with advanced MS, including high-sensitivity and high-resolution Fourier transform ion cyclotron resonance MS, to perform both single-stage MS and tandem MS (MS/MS) proteomic analyses. The technology enables broad protein identification from nanogram-size proteomics samples and allows the characterization of more abundant proteins from sub-picogram-size samples. Protein identification in such studies using MS is demonstrated from <75 zeptomole of a protein. The average proteome measurement throughput is approximately 50 proteins h(-1) using MS/MS during separations, presently requiring approximately 3 h sample(-1). Greater throughput (approximately 300 proteins h(-1)) and improved detection limits providing more comprehensive proteome coverage can be obtained by using the "accurate mass and time" tag approach developed in our laboratory. This approach provides a dynamic range of at least 10(6) for protein relative abundances and an improved basis for quantitation. These capabilities lay the foundation for studies from single or limited numbers of cells.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14647945     DOI: 10.1007/s00216-003-2329-8

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  11 in total

1.  A proteome comparison between physiological angiogenesis and angiogenesis in glioblastoma.

Authors:  Dana A M Mustafa; Lennard J Dekker; Christoph Stingl; Andreas Kremer; Marcel Stoop; Peter A E Sillevis Smitt; Johan M Kros; Theo M Luider
Journal:  Mol Cell Proteomics       Date:  2012-01-25       Impact factor: 5.911

2.  High Resolution Separations and Improved Ion Production and Transmission in Metabolomics.

Authors:  Thomas O Metz; Jason S Page; Erin S Baker; Keqi Tang; Jie Ding; Yufeng Shen; Richard D Smith
Journal:  Trends Analyt Chem       Date:  2008-03       Impact factor: 12.296

3.  Coupling methanol denaturation, immobilized trypsin digestion, and accurate mass and time tagging for liquid-chromatography-based shotgun proteomics of low nanogram amounts of RAW 264.7 cell lysate.

Authors:  Liangliang Sun; Guijie Zhu; Yihan Li; Ping Yang; Norman J Dovichi
Journal:  Anal Chem       Date:  2012-10-05       Impact factor: 6.986

Review 4.  Beyond laser microdissection technology: follow the yellow brick road for cancer research.

Authors:  Luc G Legres; Anne Janin; Christophe Masselon; Philippe Bertheau
Journal:  Am J Cancer Res       Date:  2014-01-15       Impact factor: 6.166

Review 5.  Single-cell Proteomics: Progress and Prospects.

Authors:  Ryan T Kelly
Journal:  Mol Cell Proteomics       Date:  2020-08-26       Impact factor: 5.911

6.  Identification of cellular targets in human intrahepatic cholangiocarcinoma using laser microdissection and accurate mass and time tag proteomics.

Authors:  Alexandre Dos Santos; Magali Court; Valérie Thiers; Sokhavuth Sar; Catherine Guettier; Didier Samuel; Christian Bréchot; Jérôme Garin; France Demaugre; Christophe D Masselon
Journal:  Mol Cell Proteomics       Date:  2010-05-31       Impact factor: 5.911

Review 7.  The plasma proteome, adductome and idiosyncratic toxicity in toxicoproteomics research.

Authors:  B Alex Merrick
Journal:  Brief Funct Genomic Proteomic       Date:  2008-02-12

8.  Biases in ion transmission through an electrospray ionization-mass spectrometry capillary inlet.

Authors:  Jason S Page; Ioan Marginean; Erin S Baker; Ryan T Kelly; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2009-09-02       Impact factor: 3.109

9.  Dilution-free analysis from picoliter droplets by nano-electrospray ionization mass spectrometry.

Authors:  Ryan T Kelly; Jason S Page; Ioan Marginean; Keqi Tang; Richard D Smith
Journal:  Angew Chem Int Ed Engl       Date:  2009       Impact factor: 15.336

10.  Integrated capillary zone electrophoresis-electrospray ionization tandem mass spectrometry system with an immobilized trypsin microreactor for online digestion and analysis of picogram amounts of RAW 264.7 cell lysate.

Authors:  Liangliang Sun; Guijie Zhu; Norman J Dovichi
Journal:  Anal Chem       Date:  2013-04-04       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.