Literature DB >> 14634780

Dose and image quality in the comparison of analogue and digital techniques in paediatric urology examinations.

Jan Persliden1, Ebba Helmrot, Per Hjort, Margareta Resjö.   

Abstract

In paediatric radiology it has been recognised that children have a higher risk of developing cancer from the irradiation than adults (two to three times); therefore, increased attention has been directed towards the dose to the patient. In this study the effect on patient dose and image quality in replacing the exposure in micturating cystourethrography (MCUG) examinations with the stored fluoroscopy image has been investigated. In the intravenous urography (IVU) examination we compared analogue and digital image quality, but the dose measurements were performed on a phantom. Standard clinical X-ray equipment was used. Sixty-eight patients in each of two centres were studied for the MCUG. Doses were measured with a dose-area product (DAP) meter and the image quality was scored. A non-parametric statistical analysis was performed. For the IVU, a phantom was used in the dose measurements but clinical images were scored in the comparison between analogue and digital images. For the MCUG, replacing the exposure with stored fluoroscopy images lowered the DAP value from 0.77 to 0.50 Gy cm2. The image quality did not show any difference between the techniques; however, if reflux was to be graded, exposure was needed. For the IVU, the doses could be lowered by a factor of 3 using digital techniques. The image quality showed no statistical difference between the two techniques. There is a potential for a substantial dose reduction in both MUCG and IVU examinations using digital techniques.

Entities:  

Mesh:

Year:  2003        PMID: 14634780     DOI: 10.1007/s00330-003-2144-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  8 in total

1.  Dose-image optimisation in digital radiology with a direct digital detector: an example applied to pelvic examinations.

Authors:  Jan Persliden; K-W Beckman; H Geijer; T Andersson
Journal:  Eur Radiol       Date:  2001-12-20       Impact factor: 5.315

2.  Digital radiography of scoliosis with a scanning method: radiation dose optimization.

Authors:  Håkan Geijer; Bert Verdonck; Karl-Wilhelm Beckman; Torbjörn Andersson; Jan Persliden
Journal:  Eur Radiol       Date:  2002-06-14       Impact factor: 5.315

3.  Radiation dose at small intestinal biopsies in children: results of a national study.

Authors:  J Persliden; H B Pettersson; K Fälth-Magnusson
Journal:  Acta Paediatr       Date:  1996-09       Impact factor: 2.299

4.  Radiation doses to paediatric patients undergoing micturating cystourethrography examinations and potential reduction by radiation protection optimization.

Authors:  L González; E Vañó; M J Ruiz
Journal:  Br J Radiol       Date:  1995-03       Impact factor: 3.039

5.  Radiation dose reduction in paediatric fluoroscopy using added filtration.

Authors:  R A Nicholson; A Thornton; M Akpan
Journal:  Br J Radiol       Date:  1995-03       Impact factor: 3.039

6.  Added copper filtration in digital paediatric double-contrast colon examinations: effects on radiation dose and image quality.

Authors:  B Hansson; T Finnbogason; P Schuwert; J Persliden
Journal:  Eur Radiol       Date:  1997       Impact factor: 5.315

7.  Comparison of radiation dose from intravenous urography and 99Tcm DMSA scintigraphy in children.

Authors:  T Smith; I Gordon; J P Kelly
Journal:  Br J Radiol       Date:  1998-03       Impact factor: 3.039

8.  The radiation dose to children from X-ray examinations of the pelvis and the urinary tract.

Authors:  A Almén; S Mattsson
Journal:  Br J Radiol       Date:  1995-06       Impact factor: 3.039

  8 in total
  6 in total

1.  Fluoroscopy-controlled voiding cystourethrography in infants and children: are the radiation risks trivial?

Authors:  Kostas Perisinakis; Maria Raissaki; John Damilakis; John Stratakis; John Neratzoulakis; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2005-12-03       Impact factor: 5.315

Review 2.  Applying the ALARA concept to the evaluation of vesicoureteric reflux.

Authors:  Richard S Lee; David A Diamond; Jeanne S Chow
Journal:  Pediatr Radiol       Date:  2006-09

3.  Radiation safety concerns and diagnostic reference levels for computed tomography scanners in Tamil Nadu.

Authors:  Roshan S Livingstone; Paul M Dinakaran
Journal:  J Med Phys       Date:  2011-01

Review 4.  Patient dose reduction during voiding cystourethrography.

Authors:  Valerie L Ward
Journal:  Pediatr Radiol       Date:  2006-09

5.  Comparison between patient dose arising from photofluorographic and standard fluoroscopic voiding cystourethro graphy in children with urinary tract infection [corrected].

Authors:  Malakeh Malekzadeh; Mohammad Taghi Bahreyni Toossi; Seyed Ali Alamdaran; Seid Ali Alamdaran; Mitra Naseri; Ali Beheshtian
Journal:  Nephrourol Mon       Date:  2012-06-20

6.  Radiation safety and future innovative diagnostic modalities.

Authors:  Christian Radmayr
Journal:  Adv Urol       Date:  2008
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.