A continuous glucose sensor based on wired enzyme technology -- results from a 3-day trial in patients with type 1 diabetes.

Ben Feldman1, Ronald Brazg, Sherwyn Schwartz, Richard Weinstein.   

Abstract

Wired Enzyme (Therasense, Alameda, CA) sensing technology for continuous measurement of in vivo glucose concentrations offers the benefits of (1). excellent sensor stability, (2). reduced susceptibility to variations of in vivo oxygen concentration, and (3). minimized response to common electroactive interferents. This study describes the response of 48 sensors (25 in the upper arm, 23 in the abdomen) implanted for 3 days in patients with Type 1 diabetes. Prospective calibration was performed using capillary blood; results were compared with venous plasma glucose values obtained at 15-min intervals. Ninety-eight percent of readings fell in the clinically accurate Clarke error grid zone A or clinically acceptable zone B. Choice of the site of the implanted sensor (upper arm vs. abdomen) or the capillary blood calibration site (arm vs. finger) did not affect system accuracy.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14633342     DOI: 10.1089/152091503322526978

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  57 in total

1.  Do different glucose levels at calibration influence accuracy of continuous glucose monitoring readings in vitro?

Authors:  Katherine E Iscoe; Raymond J Davey; Paul A Fournier
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

2.  Continuous glucose monitoring in subjects with type 1 diabetes: improvement in accuracy by correcting for background current.

Authors:  Joseph El Youssef; Jessica R Castle; Julia M Engle; Ryan G Massoud; W Kenneth Ward
Journal:  Diabetes Technol Ther       Date:  2010-09-30       Impact factor: 6.118

3.  Report from IPITA-TTS Opinion Leaders Meeting on the Future of β-Cell Replacement.

Authors:  Stephen T Bartlett; James F Markmann; Paul Johnson; Olle Korsgren; Bernhard J Hering; David Scharp; Thomas W H Kay; Jonathan Bromberg; Jon S Odorico; Gordon C Weir; Nancy Bridges; Raja Kandaswamy; Peter Stock; Peter Friend; Mitsukazu Gotoh; David K C Cooper; Chung-Gyu Park; Phillip OʼConnell; Cherie Stabler; Shinichi Matsumoto; Barbara Ludwig; Pratik Choudhary; Boris Kovatchev; Michael R Rickels; Megan Sykes; Kathryn Wood; Kristy Kraemer; Albert Hwa; Edward Stanley; Camillo Ricordi; Mark Zimmerman; Julia Greenstein; Eduard Montanya; Timo Otonkoski
Journal:  Transplantation       Date:  2016-02       Impact factor: 4.939

4.  Evaluation of factors affecting CGMS calibration.

Authors:  Bruce A Buckingham; Craig Kollman; Roy Beck; Andrea Kalajian; Rosanna Fiallo-Scharer; Michael J Tansey; Larry A Fox; Darrell M Wilson; Stuart A Weinzimer; Katrina J Ruedy; William V Tamborlane
Journal:  Diabetes Technol Ther       Date:  2006-06       Impact factor: 6.118

5.  A human pilot study of the fluorescence affinity sensor for continuous glucose monitoring in diabetes.

Authors:  Ralph Dutt-Ballerstadt; Colton Evans; Arun P Pillai; Eric Orzeck; Rafal Drabek; Ashok Gowda; Roger McNichols
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

Review 6.  In vitro, in vivo and post explantation testing of glucose-detecting biosensors: current methods and recommendations.

Authors:  Heidi E Koschwanez; William M Reichert
Journal:  Biomaterials       Date:  2007-04-19       Impact factor: 12.479

Review 7.  A tale of two compartments: interstitial versus blood glucose monitoring.

Authors:  Eda Cengiz; William V Tamborlane
Journal:  Diabetes Technol Ther       Date:  2009-06       Impact factor: 6.118

8.  Graphical and numerical evaluation of continuous glucose sensing time lag.

Authors:  Boris P Kovatchev; Devin Shields; Marc Breton
Journal:  Diabetes Technol Ther       Date:  2009-03       Impact factor: 6.118

9.  Continuous glucose monitoring in non-insulin-using individuals with type 2 diabetes: acceptability, feasibility, and teaching opportunities.

Authors:  Nancy A Allen; James A Fain; Barry Braun; Stuart R Chipkin
Journal:  Diabetes Technol Ther       Date:  2009-03       Impact factor: 6.118

10.  Cell based metabolic barriers to glucose diffusion: macrophages and continuous glucose monitoring.

Authors:  Ulrike Klueh; Jackman T Frailey; Yi Qiao; Omar Antar; Donald L Kreutzer
Journal:  Biomaterials       Date:  2014-01-22       Impact factor: 12.479

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.