Literature DB >> 14630469

A real-time gyroscopic system for three-dimensional measurement of lumbar spine motion.

Raymond Y W Lee1, Judi Laprade, Eric H K Fung.   

Abstract

This paper describes a new method of measuring the three-dimensional movements of the lumbar spine in real time. The measurement system consisted of solid-state gyroscopes which were attached to the trunk. They measured the angular rates of rotations in three dimensions, which were then integrated to obtain the orientation. The sensors contained gravitometers and magnetometers which provided additional information for eliminating any drift of the gyroscopes. The reliability of the data provided by the gyroscopic system was examined in a group of 19 young healthy subjects. The similarity of the movement-time curves obtained in three repeated measurements was assessed by the coefficient of multiple correlation. The coefficients were found to be high, ranging from 0.972 to 0.991. The reliability of the data was slightly lower for measuring axial rotation. The device did not only quantify the kinematic patterns in the primary plane of movements, but also the accompanying movements in the other planes. Flexion and extension was found to be mainly confined to the sagittal plane, whereas lateral bending and axial rotation always accompanied each other. It was concluded that the inertial tracking device would be a useful tool for clinical measurement as well as biomechanical investigations.

Entities:  

Mesh:

Year:  2003        PMID: 14630469     DOI: 10.1016/s1350-4533(03)00115-2

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  15 in total

1.  Development of a real-time three-dimensional spinal motion measurement system for clinical practice.

Authors:  Christina Goodvin; Edward J Park; Kevin Huang; Kelly Sakaki
Journal:  Med Biol Eng Comput       Date:  2006-11-11       Impact factor: 2.602

2.  A new method for determining lumbar spine motion using Bayesian belief network.

Authors:  Heather Ting Ma; Zhengyi Yang; James F Griffith; Ping Chung Leung; Raymond Y W Lee
Journal:  Med Biol Eng Comput       Date:  2008-02-23       Impact factor: 2.602

3.  Trunk posture monitoring with inertial sensors.

Authors:  Wai Yin Wong; Man Sang Wong
Journal:  Eur Spine J       Date:  2008-01-15       Impact factor: 3.134

4.  Inter-operator reliability and prediction bands of a novel protocol to measure the coordinated movements of shoulder-girdle and humerus in clinical settings.

Authors:  Pietro Garofalo; Andrea Giovanni Cutti; Maria Vittoria Filippi; Stefano Cavazza; Alberto Ferrari; Angelo Cappello; Angelo Davalli
Journal:  Med Biol Eng Comput       Date:  2009-02-17       Impact factor: 2.602

5.  Clinical and statistical correlation of various lumbar pathological conditions.

Authors:  J Michael Johnson; Mohamed Mahfouz; Nicholas V Battaglia; Adrija Sharma; Joseph S Cheng; Richard D Komistek
Journal:  J Biomech       Date:  2012-12-25       Impact factor: 2.712

6.  Validation of a novel spinal posture monitor: comparison with digital videofluoroscopy.

Authors:  Kieran O'Sullivan; Sabine Verschueren; Steven Pans; David Smets; Karel Dekelver; Wim Dankaerts
Journal:  Eur Spine J       Date:  2012-07-27       Impact factor: 3.134

7.  Accuracy and repeatability of an inertial measurement unit system for field-based occupational studies.

Authors:  Mark C Schall; Nathan B Fethke; Howard Chen; Sakiko Oyama; David I Douphrate
Journal:  Ergonomics       Date:  2015-10-07       Impact factor: 2.561

8.  The use of inertial sensors system for human motion analysis.

Authors:  Antonio I Cuesta-Vargas; Alejandro Galán-Mercant; Jonathan M Williams
Journal:  Phys Ther Rev       Date:  2010-12

9.  Smart garment for trunk posture monitoring: A preliminary study.

Authors:  Wai Yin Wong; Man Sang Wong
Journal:  Scoliosis       Date:  2008-05-20

10.  Reliability and measurement error of frontal and horizontal 3D spinal motion parameters in 219 patients with chronic low back pain.

Authors:  Steen Harsted; Rune M Mieritz; Gert Bronfort; Jan Hartvigsen
Journal:  Chiropr Man Therap       Date:  2016-04-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.