Literature DB >> 14623682

Mandibular angle fractures: two-miniplate fixation and complications.

Albert J Fox1, Robert M Kellman.   

Abstract

BACKGROUND: Noncompression monocortical miniplate fixation of the mandibular angle is an accepted and reliable method for providing rigid internal fixation. High complication rates have been reported for internal fixation of angle fractures.
OBJECTIVE: To analyze the outcome and complications in cases in which patients were treated with 2-miniplate fixation at the mandibular angle.
DESIGN: A retrospective analysis of outcomes for a case series.
SETTING: Treatment performed at a level 1 trauma-rated teaching hospital.
METHODS: From May 1992 to September 2001, a total of 88 patients with angle fractures of the mandible were treated with 2-miniplate fixation. Sixty-eight of the 88 patients, with 70 angle fractures, were included in the study; 13 were unavailable for follow-up and 7 had less than the minimum follow-up of 6 weeks. The time of trauma to treatment, cause of injury, and associated fractures were recorded. Postoperative complications, including infection, malunion, nonunion, dehiscence, osteomyelitis, and nerve injury due to surgical manipulation, were tabulated. Follow-up examinations were performed up to 12 weeks after surgery, with additional examinations if necessary. Postreduction panoramic radiographs were obtained in most cases.
RESULTS: No patients treated with monocortical 2-miniplate fixation had malunion, nonunion, or osteomyelitis. Twelve (17.6%) of the 68 patients were identified as having at least 1 postoperative complication. Postoperative infection occurred in 2 patients (2.9%). Infection was controlled with oral antibiotic therapy. One patient required removal of miniplates after the acute phase resolved. Occlusal disturbances were noted in 4 patients (5.9%) (2 with a slight anterior open bite, 1 with a crossbite, and 1 with premature contact of a molar) after surgery. Three of the 4 patients had associated midfacial or multiple mandibular fractures. None required further surgery. Wound dehiscence, with exposure of an underlying plate, occurred in 4 patients (5.9%); the wounds were treated conservatively and subsequently resolved. Nerve injury due to surgical manipulation occurred in 3 patients (4.4%).
CONCLUSIONS: Monocortical 2-miniplate fixation of the mandibular angle is a reliable and effective technique for providing rigid fixation. The complications were minimal in our study, and the infection rate was 2.9%, which is comparable to or better than the infection rate reported with the use of a single miniplate fixation technique in other studies. Disturbances of occlusion were associated with midfacial or additional mandibular fractures. In view of the contradictory published results, further studies are needed to determine the ideal approach for noncompression monocortical plate fixation of angle fractures.

Entities:  

Mesh:

Year:  2003        PMID: 14623682     DOI: 10.1001/archfaci.5.6.464

Source DB:  PubMed          Journal:  Arch Facial Plast Surg        ISSN: 1521-2491


  19 in total

1.  Biomechanical comparison of four mandibular angle fracture fixation techniques.

Authors:  Jose Luis Muñante-Cardenas; Luis Augusto Passeri
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2014-11-20

2.  Reconstruction of tooth-bearing portion of mandible using polyglactin 910 sutures for internal fixation in the third-world: functional and cosmetic outcome.

Authors:  Bayo Aluko-Olokun; Ademola A Olaitan; Oluseun A Aluko-Olokun
Journal:  Oral Maxillofac Surg       Date:  2016-10-29

3.  Comparison of single versus two non-compression miniplates in the management of unfavourable angle fracture of the mandible: a prospective randomized clinical study.

Authors:  Anshul Rai; Anuj Jain; Abhay Datarkar
Journal:  Oral Maxillofac Surg       Date:  2018-02-19

4.  Teeth in the line of fracture: to retain or remove?

Authors:  Jimson Samson; Reena John; Shalini Jayakumar
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2010-12

5.  Management of Mandibular Angle Fractures: Single Stainless Steel Linear Miniplate Versus Rectangular Grid Plate-A Prospective Randomised Study.

Authors:  Sridhar Reddy Kanubaddy; Sathya Kumar Devireddy; Kishore Kumar Rayadurgam; Rajsekhar Gali; Mallikarjun Rao Dasari; Sivaganesh Pampana
Journal:  J Maxillofac Oral Surg       Date:  2016-03-31

6.  The Comprehensive AOCMF Classification System: Mandible Fractures- Level 2 Tutorial.

Authors:  Carl-Peter Cornelius; Laurent Audigé; Christoph Kunz; Randal Rudderman; Carlos H Buitrago-Téllez; John Frodel; Joachim Prein
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2014-12

7.  Transoral Miniplate Fixation of Mandibular Angle Fracture with and without 2 Weeks of Maxillomandibular Fixation: A Clinical Trial Study.

Authors:  Kazem S Khiabani; Meghdad Khanian Mehmandoost
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2013-03-13

Review 8.  Fixation of mandibular angle fractures: clinical studies.

Authors:  Bruno Ramos Chrcanovic
Journal:  Oral Maxillofac Surg       Date:  2012-11-24

9.  Management of Mandibular Angle Fractures by Two Conventional 2.0-mm Miniplates: A Retrospective Study of 389 Patients.

Authors:  Giuseppe Spinelli; Davide Lazzeri; Francesco Arcuri; Domenico Valente; Tommaso Agostini
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2016-04-14

10.  3-D Miniplates Versus Conventional Miniplates in Treatment of Mandible Fractures.

Authors:  Niranjan Mishra; Nirav Thakkar; Indubhusan Kar; Shadab Ali Baig; Gaurav Sharma; Rosalin Kar; Gyana Ranjan Sahu; Krishna Gopal Birmiwal
Journal:  J Maxillofac Oral Surg       Date:  2017-12-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.