Increase in early polyethylene wear after sterilization with ethylene oxide: radiostereometric analyses of 201 total hips.

Georgios Digas1, Jonas Thanner, Bo Nivbrant, Stephan Röhrl, Håkan Ström, Johan Kärrholm.   

Abstract

We evaluated polyethylene wear by measuring femoral head penetration in 201 THA (median age 62 (31-81) years, 117 women) extracted from 5 randomized studies aimed to assess various fixation principles. There were 30 cemented all-polyethylene Lubinus cups sterilized by gamma irradiation in a reduced oxygen environment, 65 porous-coated Trilogy cups with liners gamma-sterilized in inert gas. Moreover, 37 cemented cups were sterilized with ethylene oxide (Reflection all-poly) and 69 porous-coated cups had liners sterilized in ethylene oxide (Reflection). 28 mm femoral heads were used in all cups. The patients were followed with repeated radiostereometric measurements (RSA) up to 2 years. The activity level of the patients was evaluated by a questionnaire. After 2 years, cups with polyethylene sterilized in EtO had almost twice the proximal and 3D penetration rates, as compared with gamma-sterilized polyethylene. The penetration did not differ between the gamma-irradiated designs. Using stepwise linear regression analysis, we found that the type of sterilization, age and weight were the most important predictors and that they determined the direction of the proximal penetration rate. Activity score, male gender and proximal migration of the cup had little effect. The accelerated wear observed with the EtO-sterilized polyethylene causes concerns about long-term problems and especially in younger patients.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14620972     DOI: 10.1080/00016470310017910

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  10 in total

1.  Oxidation and wear of 100-Mrad cross-linked polyethylene shelf-aged for 30 years.

Authors:  Hironobu Oonishi; Sok Chol Kim; Hiroyuki Oonishi; Masayuki Kyomoto; Shingo Masuda
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

2.  Highly crosslinked polyethylene is safe for use in total knee arthroplasty.

Authors:  Jeffrey T Hodrick; Erik P Severson; Deborah S McAlister; Brian Dahl; Aaron A Hofmann
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

3.  In vivo oxidation and surface damage in retrieved ethylene oxide-sterilized total knee arthroplasties.

Authors:  Daniel MacDonald; Josa Hanzlik; Peter Sharkey; Javad Parvizi; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

4.  The effect of poly sterilization on wear, osteolysis and survivorship of a press-fit cup at 10-year followup.

Authors:  Charles A Engh; Cara C Powers; Henry Ho; Sarah E Beykirch-Padgett; Robert H Hopper; C Anderson Engh
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

5.  Accelerated polyethylene wear and early failure of the uncemented Reflection acetabular component: a ten to fifteen-year follow-up study.

Authors:  Nicholas D Clement; Martin Mitchell; Morag E Trayner; Daniel E Porter; Graham M Lawson; Richard Burnett
Journal:  Int Orthop       Date:  2013-08-22       Impact factor: 3.075

Review 6.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

7.  Outcome in design-specific comparisons between highly crosslinked and conventional polyethylene in total hip arthroplasty.

Authors:  Per-Erik Johanson; Ove Furnes; Leif Ivar Havelin; Anne Marie Fenstad; Alma B Pedersen; Søren Overgaard; Göran Garellick; Keijo Mäkelä; Johan Kärrholm
Journal:  Acta Orthop       Date:  2017-04-04       Impact factor: 3.717

8.  Reverse hybrid and cemented hip replacement compared using radiostereometry and dual-energy X-ray absorptiometry: 43 hips followed for 2 years in a prospective trial.

Authors:  Einar Lindalen; Jon Dahl; Lars Nordsletten; Finnur Snorrason; Øystein Høvik; Stephan Röhrl
Journal:  Acta Orthop       Date:  2012-11-01       Impact factor: 3.717

9.  Superior accuracy of model-based radiostereometric analysis for measurement of polyethylene wear: A phantom study.

Authors:  M Stilling; S Kold; S de Raedt; N T Andersen; O Rahbek; K Søballe
Journal:  Bone Joint Res       Date:  2012-08-01       Impact factor: 5.853

10.  No effect of additional screw fixation of a cementless, all-polyethylene press-fit socket on migration, wear, and clinical outcome.

Authors:  Michiel J M Minten; Petra J C Heesterbeek; Maarten Spruit
Journal:  Acta Orthop       Date:  2016-06-14       Impact factor: 3.717

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.