Literature DB >> 14618060

Frequent ICD shocks due to double sensing in patients with bi-ventricular implantable cardioverter defibrillators.

Amin Al-Ahmad1, Paul J Wang, Munther K Homoud, N A Mark Estes, Mark S Link.   

Abstract

Biventricular pacing has emerged as a modality for treatment of patients with heart failure. Combined biventricular pacers and implantable cardioverter defibrillators offer treatment of heart failure as well as protection from sudden cardiac death. However, inappropriate ICD shocks as a result of double sensing due to widely spaced ventricular bipoles may pose a significant problem in these patients. We examined the ICD records of twenty-three patients with biventricular ICDs, and evaluated all episodes of double sensing that resulted in aborted or delivered therapy. In follow-up of 3.7 +/- 2.6 months, thirty-three shocks in fifteen episodes occurred in five patients (21.7%) due to double sensing. Four patients (17.4%) had aborted shocks due to double sensing. All episodes resulting in shock occurred because of sinus tachycardia or supraventricular tachycardia above the upper programmed pacing rate of the device with resultant AV conduction and double sensing of the nonpaced ventricular depolarization. In conclusion, double sensing of the R-wave is a common and clinically important cause of inappropriate ICD detection and shock in patients with biventricular ICDs. Appropriate programming of the ICD can prevent episodes of inappropriate shocks.

Entities:  

Mesh:

Year:  2003        PMID: 14618060     DOI: 10.1023/a:1027455713120

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  17 in total

1.  Reversal of left ventricular remodeling by synchronous biventricular pacing in heart failure.

Authors:  C P Lau; C M Yu; E Chau; K Fan; H F Tse; K Lee; M O Tang; S H Wan; T C Law; P Y Lee; Y M Lam; M R Hill
Journal:  Pacing Clin Electrophysiol       Date:  2000-11       Impact factor: 1.976

2.  Biventricular pacing in end-stage heart failure improves functional capacity and left ventricular function.

Authors:  P F Bakker; H W Meijburg; J W de Vries; M M Mower; A C Thomas; M L Hull; E O Robles De Medina; J J Bredée
Journal:  J Interv Card Electrophysiol       Date:  2000-06       Impact factor: 1.900

3.  Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction.

Authors:  Arthur J Moss; Wojciech Zareba; W Jackson Hall; Helmut Klein; David J Wilber; David S Cannom; James P Daubert; Steven L Higgins; Mary W Brown; Mark L Andrews
Journal:  N Engl J Med       Date:  2002-03-19       Impact factor: 91.245

4.  The acute effects of transvenous biventricular pacing in a patient with congestive heart failure.

Authors:  M Debrunner; B Naegeli; O Bertel
Journal:  Chest       Date:  2000-06       Impact factor: 9.410

5.  Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators.

Authors:  A J Moss; W J Hall; D S Cannom; J P Daubert; S L Higgins; H Klein; J H Levine; S Saksena; A L Waldo; D Wilber; M W Brown; M Heo
Journal:  N Engl J Med       Date:  1996-12-26       Impact factor: 91.245

6.  Potential benefit of biventricular pacing in patients with congestive heart failure and ventricular tachyarrhythmia.

Authors:  C Stellbrink; A Auricchio; B Diem; O A Breithardt; M Kloss; F A Schöndube; H Klein; B J Messmer; P Hanrath
Journal:  Am J Cardiol       Date:  1999-03-11       Impact factor: 2.778

7.  Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay.

Authors:  S Cazeau; C Leclercq; T Lavergne; S Walker; C Varma; C Linde; S Garrigue; L Kappenberger; G A Haywood; M Santini; C Bailleul; J C Daubert
Journal:  N Engl J Med       Date:  2001-03-22       Impact factor: 91.245

8.  Efficacy of biventricular sensing and treatment of ventricular arrhythmias.

Authors:  M Bocchiardo; M Achtelik; F Gaita; H J Trappe; I Lozano; S Higgins; E Daoud; P Yong; C Duby
Journal:  Pacing Clin Electrophysiol       Date:  2000-11       Impact factor: 1.976

9.  Should stimulation therapy for congestive heart failure be combined with defibrillation backup?

Authors:  F Gaita; M Bocchiardo; M C Porciani; L Vivalda; A Colella; P Di Donna; D Caponi; M Bruzzone; L Padeletti
Journal:  Am J Cardiol       Date:  2000-11-02       Impact factor: 2.778

10.  Matching approved "nondedicated" hardware to obtain biventricular pacing and defibrillation: feasibility and troubleshooting.

Authors:  Logan Kanagaratnam; Stephen Pavia; Robert Schweikert; Nassir Marrouche; Cathy Lam; Miguel Abreu; Elizabeth Ching; Mina Chung; Walid Saliba; Mark Niebauer; Bruce Wilkoff; Patrick Tchou; Andrea Natale
Journal:  Pacing Clin Electrophysiol       Date:  2002-07       Impact factor: 1.976

View more
  3 in total

Review 1.  Cardiac resynchronization therapy: strategies for device programming, troubleshooting and follow-up.

Authors:  Safwat Gassis; Angel R León
Journal:  J Interv Card Electrophysiol       Date:  2005-09       Impact factor: 1.900

2.  Electrocardiographic follow-up of biventricular pacemakers.

Authors:  S Serge Barold; Bengt Herweg; Michael Giudici
Journal:  Ann Noninvasive Electrocardiol       Date:  2005-04       Impact factor: 1.468

3.  Inappropriate shock during left ventricular threshold measurement in a patient with coexisting ICD and a biventricular pacemaker.

Authors:  M Azizi; H Nägele
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2007-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.