Literature DB >> 8428079

Improved cine MR imaging of left ventricular wall motion with gadopentetate dimeglumine.

D J Pennell1, S R Underwood, D B Longmore.   

Abstract

The assessment of left ventricular wall motion with cine magnetic resonance imaging in the cardiac long axes is useful; however, image quality is limited by reduced signal intensity due to saturation of blood flowing predominantly in plane. Twenty subjects were studied to evaluate the effects of gadopentetate dimeglumine on contrast between blood and myocardium. Contrast improved significantly on contrast agent-enhanced images in the long axes, at both end-systole (vertical axis, +62%, P < .0001; horizontal axis, +67%, P < .0001) and end-diastole (vertical axis, +50%, P < .0001; horizontal axis, +26%, P < .004). The increase in the short axis was less and significant only at end-systole (+25%, P < .0001). Subjective scoring of the cines also showed a significant and clinically useful improvement in the long axes (P < .0001 for both) on contrast-enhanced images. Improved contrast was most evident for 10 minutes after injection, but persisted for up to 20 minutes at end-systole in the long axes. Gadopentetate dimeglumine is useful for cine imaging of left ventricular wall motion when saturation effects prevent adequate clinical assessment.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8428079     DOI: 10.1002/jmri.1880030104

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  3 in total

1.  Improved functional cardiac MR imaging using the intravascular contrast agent CLARISCAN.

Authors:  I Paetsch; H Thiele; B Schnackenburg; A Bornstedt; A Müller-York; J Schwab; E Fleck; E Nagel
Journal:  Int J Cardiovasc Imaging       Date:  2003-08       Impact factor: 2.357

Review 2.  Magnetic resonance imaging in the assessment of ventricular remodeling and viability.

Authors:  Michael Jerosch-Herold; Raymond Y Kwong
Journal:  Curr Heart Fail Rep       Date:  2008-03

3.  Accuracy of contrast-enhanced cine-MR sequences in the assessment of left ventricular function: comparison with precontrast cine-MR sequences. Results of a bicentric study.

Authors:  Jean-Christophe Lasalarie; Jean-Michel Serfaty; Christophe Carre; David Messika-Zeitoun; Christophe Jeannot; Elisabeth Schouman-Claeys; Jean-Pierre Laissy
Journal:  Eur Radiol       Date:  2007-05-08       Impact factor: 5.315

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.