Literature DB >> 14588040

Incorporation of a venturi device in electrospray ionization.

Li Zhou1, Bingfang Yue, David V Dearden, Edgar D Lee, Alan L Rockwood, Milton L Lee.   

Abstract

Electrospray ionization has grown to be one of the most commonly used ionization techniques for mass spectrometry, and efforts continue to improve its performance. Typically, the sprayer tip must be very close to the entrance orifice of the mass spectrometer in order to maximize the conduction of ions from the sprayer into the mass spectrometer. However, because of space-charge repulsion, most ions never reach the sampling orifice. In this work, an industrial air amplifier, for which the working mechanism is based on venturi and coanda effects, was added between an electrospray ionization source and a time-of-flight mass spectrometer. When a series of reserpine solutions (0.5, 1.0, 5.0, and 10.0 microM) were monitored using mass spectrometry, an over 5-fold increase in m/z 609.3 ion intensity was measured for a separation distance of 14 mm between the electrospray tip and interface capillary inlet, as compared to when the electrospray tip was in its normal position 1 mm in front of the inlet without the amplifier. When a voltage was applied to the air amplifier to further assist in focusing the electrosprayed ions, an approximately 18-fold increase in m/z 609.3 ion intensity was obtained. In addition, a 34-fold reduction in method detection limit was observed.

Entities:  

Year:  2003        PMID: 14588040     DOI: 10.1021/ac020786e

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  13 in total

1.  Investigation of electrospray ionization and electrostatic focusing devices using a three-dimensional electrospray current density profiler.

Authors:  J Will Thompson; John W Eschelbach; Richard T Wilburn; James W Jorgenson
Journal:  J Am Soc Mass Spectrom       Date:  2005-03       Impact factor: 3.109

2.  Incorporation of a flared inlet capillary tube on a fourier transform ion cyclotron resonance mass spectrometer.

Authors:  Si Wu; Kai Zhang; Nathan K Kaiser; James E Bruce; David C Prior; Gordon A Anderson
Journal:  J Am Soc Mass Spectrom       Date:  2006-04-17       Impact factor: 3.109

3.  Generation and detection of multiply-charged peptides and proteins by matrix-assisted laser desorption electrospray ionization (MALDESI) Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Jason S Sampson; Adam M Hawkridge; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2006-09-06       Impact factor: 3.109

4.  Improving mass spectrometer sensitivity using a high-pressure electrodynamic ion funnel interface.

Authors:  Yehia Ibrahim; Keqi Tang; Aleksey V Tolmachev; Alexandre A Shvartsburg; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2006-07-12       Impact factor: 3.109

5.  Design, Modeling, Fabrication, and Evaluation of the Air Amplifier for Improved Detection of Biomolecules by Electrospray Ionization Mass Spectrometry.

Authors:  Guillaume Robichaud; R Brent Dixon; Amarnatha S Potturi; Dan Cassidy; Jack R Edwards; Alex Sohn; Thomas A Dow; David C Muddiman
Journal:  Int J Mass Spectrom       Date:  2011-03-01       Impact factor: 1.986

6.  Capillary-based multi nanoelectrospray emitters: improvements in ion transmission efficiency and implementation with capillary reversed-phase LC-ESI-MS.

Authors:  Ryan T Kelly; Jason S Page; Rui Zhao; Wei-Jun Qian; Heather M Mottaz; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2007-11-29       Impact factor: 6.986

7.  Remote mass spectrometric sampling of electrospray- and desorption electrospray-generated ions using an air ejector.

Authors:  R Brent Dixon; Michael S Bereman; David C Muddiman; Adam M Hawkridge
Journal:  J Am Soc Mass Spectrom       Date:  2007-07-29       Impact factor: 3.109

8.  Probing the mechanisms of an air amplifier using a LTQ-FT-ICR-MS and fluorescence spectroscopy.

Authors:  R Brent Dixon; David C Muddiman; Adam M Hawkridge; A G Fedorov
Journal:  J Am Soc Mass Spectrom       Date:  2007-08-16       Impact factor: 3.109

9.  High Resolution Separations and Improved Ion Production and Transmission in Metabolomics.

Authors:  Thomas O Metz; Jason S Page; Erin S Baker; Keqi Tang; Jie Ding; Yufeng Shen; Richard D Smith
Journal:  Trends Analyt Chem       Date:  2008-03       Impact factor: 12.296

10.  Construction of a versatile high precision ambient ionization source for direct analysis and imaging.

Authors:  Jason S Sampson; Adam M Hawkridge; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2008-06-28       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.