Literature DB >> 14587018

Optimization of diffusion measurements using Cramer-Rao lower bound theory and its application to articular cartilage.

Oscar Brihuega-Moreno1, Frank P Heese, Laurance D Hall.   

Abstract

A novel approach to optimized diffusion measurements by minimizing the Cramer-Rao lower bound (CRLB) with respect to the b-values used for diffusion measurement was investigated. The applicability of the CRLB to these measurements is shown by the close agreement between the CRLB prediction and the actual precision obtained from experimental results. Where studies using a propagation-of-errors approach have restricted the optimization of the diffusion measurement to two b-values and to specific diffusion coefficient values, the CRLB approach sets no bounds on the number of b-values and is applicable to any system. The optimal number of b-values depends on the ratio of the maximum and minimum diffusion coefficients in the sample (the D(ratio)) and on the number of acquisitions. For a D(ratio) above 6.8 the optimal number of b-values increases to three; at a D(ratio) of 21.8 it increases to four. The optimized sampling schemes for ADC measurements in a variety of representative tissues found in the human body are given. For cartilage the optimal five-point acquisition scheme requires one measurement at a b-value of 0 and four at 1036 sec mm(-2), whereas brain requires one at 0, three at 660, and one at 1987 sec mm(-2). Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2003        PMID: 14587018     DOI: 10.1002/mrm.10628

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  15 in total

1.  Flexible and efficient optimization of quantitative sequences using automatic differentiation of Bloch simulations.

Authors:  Philip K Lee; Lauren E Watkins; Timothy I Anderson; Guido Buonincontri; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2019-05-26       Impact factor: 4.668

2.  Apparent diffusion coefficients of the five major metabolites measured in the human brain in vivo at 3T.

Authors:  Dinesh K Deelchand; Edward J Auerbach; Małgorzata Marjańska
Journal:  Magn Reson Med       Date:  2017-10-17       Impact factor: 4.668

3.  Fisher information and Cramér-Rao lower bound for experimental design in parallel imaging.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Magn Reson Med       Date:  2017-11-01       Impact factor: 4.668

4.  Optimized inversion recovery sequences for quantitative T1 and magnetization transfer imaging.

Authors:  Ke Li; Zhongliang Zu; Junzhong Xu; Vaibhav A Janve; John C Gore; Mark D Does; Daniel F Gochberg
Journal:  Magn Reson Med       Date:  2010-08       Impact factor: 4.668

5.  Optimization of spin-lock times in T mapping of knee cartilage: Cramér-Rao bounds versus matched sampling-fitting.

Authors:  Marcelo V W Zibetti; Azadeh Sharafi; Ravinder R Regatte
Journal:  Magn Reson Med       Date:  2021-11-04       Impact factor: 4.668

6.  On the selection of sampling points for myocardial T1 mapping.

Authors:  Mehmet Akçakaya; Sebastian Weingärtner; Sébastien Roujol; Reza Nezafat
Journal:  Magn Reson Med       Date:  2014-05-06       Impact factor: 4.668

7.  Estimation of optimal b-value sets for obtaining apparent diffusion coefficient free from perfusion in non-small cell lung cancer.

Authors:  Kishor Karki; Geoffrey D Hugo; John C Ford; Kathryn M Olsen; Siddharth Saraiya; Robert Groves; Elisabeth Weiss
Journal:  Phys Med Biol       Date:  2015-09-25       Impact factor: 3.609

8.  Diffusion-weighted magnetic resonance imaging for assessment of lung lesions: repeatability of the apparent diffusion coefficient measurement.

Authors:  L Bernardin; N H M Douglas; D J Collins; S L Giles; E A M O'Flynn; M Orton; N M deSouza
Journal:  Eur Radiol       Date:  2013-11-26       Impact factor: 5.315

9.  A unified optimization approach for diffusion tensor imaging technique.

Authors:  Wei Gao; Hongtu Zhu; Weili Lin
Journal:  Neuroimage       Date:  2008-11-01       Impact factor: 6.556

10.  Diffusion-weighted (DW) MRI in lung cancers: ADC test-retest repeatability.

Authors:  Alex Weller; Marianthi Vasiliki Papoutsaki; John C Waterton; Arturo Chiti; Sigrid Stroobants; Joost Kuijer; Matthew Blackledge; Veronica Morgan; Nandita M deSouza
Journal:  Eur Radiol       Date:  2017-04-10       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.