Literature DB >> 14587011

Triggered, navigated, multi-baseline method for proton resonance frequency temperature mapping with respiratory motion.

Karl K Vigen1, Bruce L Daniel, John M Pauly, Kim Butts.   

Abstract

A technique is presented for the acquisition of temperature maps in the presence of variable respiratory motion using the proton resonance frequency (PRF) shift. The technique uses respiratory triggering, diaphragm position determination with a navigator echo, and the collection of multiple baseline images to generate temperature maps. Laser ablations were performed in an ex vivo liver phantom undergoing variable simulated respiratory motion and in vivo in four porcine livers, demonstrating a reduction of artifacts in the computed temperature maps compared with conventional single baseline techniques, both uncorrected and corrected for motion. Copyright 2003 Wiley-Liss, Inc.

Mesh:

Year:  2003        PMID: 14587011     DOI: 10.1002/mrm.10608

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  40 in total

1.  Hybrid referenceless and multibaseline subtraction MR thermometry for monitoring thermal therapies in moving organs.

Authors:  William A Grissom; Viola Rieke; Andrew B Holbrook; Yoav Medan; Michael Lustig; Juan Santos; Michael V McConnell; Kim Butts Pauly
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Improved hyperthermia treatment control using SAR/temperature simulation and PRFS magnetic resonance thermal imaging.

Authors:  Zhen Li; Martin Vogel; Paolo F Maccarini; Vadim Stakhursky; Brian J Soher; Oana I Craciunescu; Shiva Das; Omar A Arabe; Williams T Joines; Paul R Stauffer
Journal:  Int J Hyperthermia       Date:  2010-11-11       Impact factor: 3.914

3.  Towards fast and accurate temperature mapping with proton resonance frequency-based MR thermometry.

Authors:  Jing Yuan; Chang-Sheng Mei; Lawrence P Panych; Nathan J McDannold; Bruno Madore
Journal:  Quant Imaging Med Surg       Date:  2012

4.  Influence of geometric and material properties on artifacts generated by interventional MRI devices: Relevance to PRF-shift thermometry.

Authors:  Ken Tatebe; Elizabeth Ramsay; Charles Mougenot; Mohammad Kazem; Hamed Peikari; Michael Bronskill; Rajiv Chopra
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

5.  Multi-echo MR thermometry using iterative separation of baseline water and fat images.

Authors:  Megan E Poorman; Ieva Braškutė; Lambertus W Bartels; William A Grissom
Journal:  Magn Reson Med       Date:  2018-11-05       Impact factor: 4.668

6.  Respiration artifact correction in three-dimensional proton resonance frequency MR thermometry using phase navigators.

Authors:  Bryant T Svedin; Allison Payne; Dennis L Parker
Journal:  Magn Reson Med       Date:  2015-08-13       Impact factor: 4.668

7.  Referenceless MR thermometry for monitoring thermal ablation in the prostate.

Authors:  Viola Rieke; Adam M Kinsey; Anthony B Ross; William H Nau; Chris J Diederich; Graham Sommer; Kim Butts Pauly
Journal:  IEEE Trans Med Imaging       Date:  2007-06       Impact factor: 10.048

8.  Accurate MR thermometry by hyperpolarized 129 Xe.

Authors:  Le Zhang; Alex Burant; Andrew McCallister; Victor Zhao; Karl M Koshlap; Simone Degan; Michael Antonacci; Rosa Tamara Branca
Journal:  Magn Reson Med       Date:  2016-10-19       Impact factor: 4.668

9.  Real-time MR thermometry for monitoring HIFU ablations of the liver.

Authors:  Andrew B Holbrook; Juan M Santos; Elena Kaye; Viola Rieke; Kim Butts Pauly
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

10.  Low-rank plus sparse compressed sensing for accelerated proton resonance frequency shift MR temperature imaging.

Authors:  Zhipeng Cao; John C Gore; William A Grissom
Journal:  Magn Reson Med       Date:  2019-01-31       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.