Literature DB >> 14579394

High field human imaging.

David G Norris1.   

Abstract

This review article examines the state of knowledge regarding human imaging using MRI at high main magnetic field strengths. The article starts with a summary of the technical issues associated with magnetic field strengths in the range of 3-8 T, including magnet characteristics and the properties of radiofrequency magnetic fields, with special reference to sensitivity, power deposition, and homogeneity. The published data on tissue-water relaxation times in the brain is tabulated and the implications for contrast and pulse sequence implementation is elucidated. The behavior of the major fast imaging sequences, fast low angle shot (FLASH), rapid acquisition with relaxation enhancement (RARE), and echo planar imaging (EPI), is examined in this context. A number of anatomical images from 3 T systems are presented as examples. Particular attention is given to various forms of vascular imaging, namely, time of flight angiography, venography, and arterial spin labeling. The most complex changes in contrast with main magnetic field strength are in activation studies utilizing the blood oxygen level dependent mechanism, which are examined in detail. Improvements in spatial specificity are emphasized, particularly in conjunction with spin-echo imaging. The article concludes with a discussion of the current status and the potential impact of technical developments such as parallel imaging. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2003        PMID: 14579394     DOI: 10.1002/jmri.10390

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  47 in total

1.  Functional localization in the human brain: Gradient-Echo, Spin-Echo, and arterial spin-labeling fMRI compared with neuronavigated TMS.

Authors:  Svenja Diekhoff; Kamil Uludağ; Roland Sparing; Marc Tittgemeyer; Mustafa Cavuşoğlu; D Yves von Cramon; Christian Grefkes
Journal:  Hum Brain Mapp       Date:  2011-03       Impact factor: 5.038

2.  Comparison of flow artifacts between 2D-FLAIR and 3D-FLAIR sequences at 3 T.

Authors:  Shinji Naganawa; Tokiko Koshikawa; Tatsuya Nakamura; Hisashi Kawai; Hiroshi Fukatsu; Takeo Ishigaki; Tomomi Komada; Katsuya Maruyama; Osamu Takizawa
Journal:  Eur Radiol       Date:  2004-06-19       Impact factor: 5.315

Review 3.  Occupational exposure in MRI.

Authors:  D W McRobbie
Journal:  Br J Radiol       Date:  2012-04       Impact factor: 3.039

4.  Self-refocused adiabatic pulse for spin echo imaging at 7 T.

Authors:  Priti Balchandani; Mohammad Mehdi Khalighi; Gary Glover; John Pauly; Daniel Spielman
Journal:  Magn Reson Med       Date:  2011-09-27       Impact factor: 4.668

Review 5.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

6.  Does high-field MR imaging have an influence on the classification of patients with clinically isolated syndromes according to current diagnostic mr imaging criteria for multiple sclerosis?

Authors:  M P Wattjes; M Harzheim; C K Kuhl; J Gieseke; S Schmidt; L Klotz; T Klockgether; H H Schild; G G Lutterbey
Journal:  AJNR Am J Neuroradiol       Date:  2006-09       Impact factor: 3.825

7.  High spatial resolution contrast-enhanced MR angiography of the supraaortic arteries using the quadrature body coil at 3.0T: a feasibility study.

Authors:  Winfried A Willinek; Thomas Bayer; Jürgen Gieseke; Marcus von Falkenhausen; Torsten Sommer; Romhild Hoogeveen; Kai Wilhelm; Horst Urbach; Hans H Schild
Journal:  Eur Radiol       Date:  2006-08-30       Impact factor: 5.315

8.  Advantages and pitfalls in 3T MR brain imaging: a pictorial review.

Authors:  Bernd L Schmitz; Andrik J Aschoff; Martin H K Hoffmann; Georg Grön
Journal:  AJNR Am J Neuroradiol       Date:  2005-10       Impact factor: 3.825

Review 9.  Whole-body MRI at high field: technical limits and clinical potential.

Authors:  Fritz Schick
Journal:  Eur Radiol       Date:  2005-01-27       Impact factor: 5.315

10.  MR imaging of gastric cancer in vitro: accuracy of invasion depth diagnosis.

Authors:  Chiho Sato; Shinji Naganawa; Hisashi Kumada; Shunichi Miura; Takeo Ishigaki
Journal:  Eur Radiol       Date:  2004-07-17       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.