Literature DB >> 14578433

Anatomy of a supergroup: does a criterion of normal perimetric performance generate a supernormal population?

Andrew John Anderson1, Chris A Johnson.   

Abstract

PURPOSE: To interpret individual results from automated perimeters, a normative database must be developed. Typically, a set of criteria determines those subjects that may be included in the database. This study examined whether a criterion of normal performance on an established perimeter generates a subgroup with supernormal perimetric performance.
METHODS: The right-eye perimetric results of 100 subjects were analyzed. Subjects had visual acuities of 6/12 or better, no history of eye disease, and normal slit lamp biomicroscopic and ophthalmoscopic examinations. Subjects performed test-retest visual field examinations on a Humphrey Field Analyzer (HFA) 24-2 test (Zeiss Humphrey Systems, Dublin, CA), and on a custom frequency-doubling (FD) perimeter with targets spaced in the same 24-2 pattern.
RESULTS: Test-retest correlation (Spearman rank correlation coefficients, rs) for mean defect (MD) and pattern SD (PSD) were 0.65 and 0.40 (HFA), and 0.82 and 0.39 (FD perimeter). Three subjects with HFA MDs in the lower 5% had similarly low MDs on retest, whereas no subject was common between the test and retest for the lower 5% of HFA PSD. Correlation between the HFA and FD test results were 0.41 (MD) and 0.05 (PSD). Based on these correlations, the bias introduced into perimetric probability limits were determined, by using Monte Carlo simulations.
CONCLUSIONS: Although a criterion of a normal MD may produce a subpopulation with supernormal perimetric performance, a criterion of a normal PSD is less likely to do so. Also, a criterion on one test type is less likely to create a supernormal group on a different test type. The bias introduced into perimetric probability limits is small.

Entities:  

Mesh:

Year:  2003        PMID: 14578433     DOI: 10.1167/iovs.03-0058

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  4 in total

1.  Characteristics of the normative database for the Humphrey matrix perimeter.

Authors:  Andrew John Anderson; Chris A Johnson; Murray Fingeret; John L Keltner; Paul G D Spry; Michael Wall; John S Werner
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-04       Impact factor: 4.799

2.  Development and evaluation of a linear staircase strategy for the measurement of perimetric sensitivity.

Authors:  Rizwan Malik; William H Swanson; David F Garway-Heath
Journal:  Vision Res       Date:  2006-06-09       Impact factor: 1.886

3.  Measuring visual function in age-related macular degeneration with frequency-doubling (matrix) perimetry.

Authors:  Andrew John Anderson; Chris A Johnson; John S Werner
Journal:  Optom Vis Sci       Date:  2011-07       Impact factor: 1.973

4.  Application of Pattern Recognition Analysis to Optimize Hemifield Asymmetry Patterns for Early Detection of Glaucoma.

Authors:  Jack Phu; Sieu K Khuu; Bang V Bui; Michael Kalloniatis
Journal:  Transl Vis Sci Technol       Date:  2018-09-04       Impact factor: 3.283

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.