Literature DB >> 14570307

Influence of the metering chamber volume and actuator design on the aerodynamic particle size of a metered dose inhaler.

Julianne Berry1, Susan Heimbecher, John L Hart, Joel Sequeira.   

Abstract

Presented in this work are the results of a study designed to investigate the impact of the valve metering chamber volume and actuator design on the aerodynamic particle size distribution (PSD) of a suspension metered dose inhaler (MDI) containing propellant HFA-227. It was hypothesized that the valve metering volume and the actuator design in the MDI could influence the PSD of the emitted dose since it would affect the aerosol spray dynamics. The PSD results from this study, measured using cascade impaction, revealed that samples containing an actuator intended for oral delivery (rectangular mouthpiece and orifice diameter of approximately 0.5 mm) produced a higher fine particle dose (FPD) than those containing an actuator intended for nasal delivery (circular nosetip and orifice diameter of approximately 1 mm). In addition, the drug PSD profile was shown to be more sensitive to differences in the particle size of the suspended material when the oral actuator was used compared to when the nasal actuator was used. The valve metering chamber (25 vs. 63 microL volume) did not appear to have a major effect on the product aerodynamic PSD or the droplet size. These results demonstrate the importance of actuator design and orifice size in determining the aerodynamic PSD of an MDI.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14570307     DOI: 10.1081/ddc-120024182

Source DB:  PubMed          Journal:  Drug Dev Ind Pharm        ISSN: 0363-9045            Impact factor:   3.225


  4 in total

1.  Spray pattern analysis for metered dose inhalers: effect of actuator design.

Authors:  Hugh Smyth; Geoff Brace; Tony Barbour; Jim Gallion; Joe Grove; Anthony J Hickey
Journal:  Pharm Res       Date:  2006-06-21       Impact factor: 4.200

Review 2.  Advances in metered dose inhaler technology: hardware development.

Authors:  Stephen W Stein; Poonam Sheth; P David Hodson; Paul B Myrdal
Journal:  AAPS PharmSciTech       Date:  2013-12-20       Impact factor: 3.246

3.  The influence of actuator materials and nozzle designs on electrostatic charge of pressurised metered dose inhaler (pMDI) formulations.

Authors:  Yang Chen; Paul M Young; David F Fletcher; Hak Kim Chan; Edward Long; David Lewis; Tanya Church; Daniela Traini
Journal:  Pharm Res       Date:  2013-12-03       Impact factor: 4.200

4.  Investigations into the formulation of metered dose inhalers of salmeterol xinafoate and fluticasone propionate microcrystals.

Authors:  Darragh Murnane; Gary P Martin; Christopher Marriott
Journal:  Pharm Res       Date:  2008-05-29       Impact factor: 4.200