Literature DB >> 14550437

Accuracy of bladder volume determinations by ultrasonography: are they accurate over entire bladder volume range?

Seok Soo Byun1, Hyeon Hoe Kim, Eunsik Lee, Jae-Seung Paick, Weechang Kamg, Seung-June Oh.   

Abstract

OBJECTIVES: To investigate the accuracy of a portable three-dimensional hand-held BladderScan (BS) and two-dimensional conventional ultrasonography (CUS) in the estimation of bladder volumes.
METHODS: The bladder volume of 65 subjects was measured during filling cystometry using two ultrasound modalities. Serial measurements were performed when the infused volume reached 100, 200, 300, and 400 mL; the investigator measured the volumes three times each with BS and CUS. Each corresponding true volume was calculated by interpolation using zero volume and the final catheterized volume at the end of cystometry. The accuracy of the two ultrasound methods was compared using raw scaled values of the volumes and the percentage of differences of volume.
RESULTS: Bladder volumes determined by CUS and BS were underestimated by 21.8% and 3.3% (mean values), respectively. The percentage of differences of volume of BS was not statistically significant (P >0.05), but that of CUS was statistically significant (P <0.00001). No significant percentage of differences of volume change according to the volume status was observed by either ultrasound measurement method (P >0.05). Linear regression analysis between the true volumes and the raw scaled volumes showed that the slope of the BS was closer to 1.0 than that of the CUS, and the difference was statistically significant (P <0.001). The effects of diagnosis, age, sex, and body mass index were not significant in determining the bladder volume by either method (P >0.05).
CONCLUSIONS: Our results demonstrated that a three-dimensional hand-held scanner measures the bladder volume in a reproducible and accurate manner for a wide range of bladder volumes and is superior to two-dimensional stationary ultrasonography.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14550437     DOI: 10.1016/s0090-4295(03)00559-4

Source DB:  PubMed          Journal:  Urology        ISSN: 0090-4295            Impact factor:   2.649


  15 in total

Review 1.  Ambulatory urodynamic monitoring: state of the art and future directions.

Authors:  Benjamin Abelson; Steve Majerus; Daniel Sun; Bradley C Gill; Eboo Versi; Margot S Damaser
Journal:  Nat Rev Urol       Date:  2019-05       Impact factor: 14.432

2.  Three-dimensional ultrasound reconstruction of the pelvicaliceal system: an in-vitro study.

Authors:  Khurshid R Ghani; James Pilcher; Uday Patel; David Rowland; Daruish Nassiri; Ken Anson
Journal:  World J Urol       Date:  2008-06-07       Impact factor: 4.226

Review 3.  A comprehensive survey on non-invasive wearable bladder volume monitoring systems.

Authors:  Morteza Zakeri Nasrabadi; Hamideh Tabibi; Mahsa Salmani; Mahdieh Torkashvand; Eisa Zarepour
Journal:  Med Biol Eng Comput       Date:  2021-07-14       Impact factor: 2.602

4.  Evaluation of voiding dysfunction and measurement of bladder volume.

Authors:  Christopher E Kelly
Journal:  Rev Urol       Date:  2004

5.  Evaluating men with benign prostatic hyperplasia.

Authors:  Herbert Lepor
Journal:  Rev Urol       Date:  2004

6.  [Evaluation of residual urine volume by ultrasound for detection of urinary bladder dysfunction after surgical therapy of rectal cancer].

Authors:  T Borschitz; W Kneist; T Junginger
Journal:  Chirurg       Date:  2005-07       Impact factor: 0.955

7.  A noninvasive bladder sensory test supports a role for dysmenorrhea increasing bladder noxious mechanosensitivity.

Authors:  Frank F Tu; Aliza E Epstein; Kristen E Pozolo; Debra L Sexton; Alexandra I Melnyk; Kevin M Hellman
Journal:  Clin J Pain       Date:  2013-10       Impact factor: 3.442

8.  Is Doppler planimetry a valid technique for the evaluation of postpartum urinary bladder volume?

Authors:  James W S Lee; Stergios K Doumouchtsis; Michelle M Fynes
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2008-01-30

9.  Comparison of 2D and 3D ultrasound methods to measure serial bladder volumes during filling: Steps toward development of non-invasive ultrasound urodynamics.

Authors:  Anna S Nagle; Rachel J Bernardo; Jary Varghese; Laura R Carucci; Adam P Klausner; John E Speich
Journal:  Bladder (San Franc)       Date:  2018-01-04

10.  cExternal beam radiation results in minimal changes in post void residual urine volumes during the treatment of clinically localized prostate cancer.

Authors:  Peter F Orio; Gregory S Merrick; Zachariah A Allen; Wayne M Butler; Kent E Wallner; Brian S Kurko; Robert W Galbreath
Journal:  Radiat Oncol       Date:  2009-07-22       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.