Literature DB >> 1452708

Value of extended agitation and subculture of BACTEC NR 660 aerobic resin blood culture bottles for clinical yeast isolates.

E Prevost-Smith1, N Hutton.   

Abstract

From 10,351 blood cultures, we prospectively studied 1,000 BACTEC NR 660 aerobic resin blood culture bottles (26+ and Peds Plus) for patients suspected of having yeast septicemia to determine whether extended agitation and subculturing would increase the recovery of yeasts. Aerobic bottles were agitated continuously for 144 h. On day 7, 1,000 culture-negative aerobic bottles which had fungal blood culture requests were agitated for an additional 14 days. During this time they were subcultured twice and read twice by BACTEC NR 660. ON days 1 to 7, 81 bottles were cultured positive for yeasts from 36 patients, which included 44 isolates of Candida albicans, averaging 1.4 days to detection, and 12 isolates of Cryptococcus neoformans, averaging 3.8 days to detection. The average detection time for all yeasts was 2.2 days. On days 7 to 21, no yeasts were detected by BACTEC or recovered from the subcultures. We conclude that when continuously agitated for at least 5 full days (120 h), the BACTEC NR 660 aerobic resin bottles reliably isolate yeasts, and it is unnecessary to subculture or hold these bottles beyond 5 days. It also eliminates the need for an additional blood culture system for yeast detection, thus saving (i) confusion in the collection process, (ii) patients' blood and money, and (iii) laboratory technologists' time.

Entities:  

Mesh:

Year:  1992        PMID: 1452708      PMCID: PMC270640          DOI: 10.1128/jcm.30.12.3239-3242.1992

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  13 in total

Review 1.  Fungal blood cultures.

Authors:  A Telenti; G D Roberts
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

2.  Clinical comparison of a new automated infrared blood culture system with the BACTEC 460 system.

Authors:  D Jungkind; J Millan; S Allen; J Dyke; E Hill
Journal:  J Clin Microbiol       Date:  1986-02       Impact factor: 5.948

3.  Large-scale clinical comparison of the lysis-centrifugation and radiometric systems for blood culture.

Authors:  P Brannon; T E Kiehn
Journal:  J Clin Microbiol       Date:  1985-12       Impact factor: 5.948

4.  Comparison of the lysis centrifugation and radiometric blood culture systems for recovery of yeast.

Authors:  B A Body; M A Pfaller; J Durrer; F Koontz; D H Gröschel
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1988-06       Impact factor: 3.267

5.  Evaluation of a lysis-centrifugation system for recovery of yeasts and filamentous fungi from blood.

Authors:  J Bille; L Stockman; G D Roberts; C D Horstmeier; D M Ilstrup
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

6.  Effect of hydrogen peroxide on growth of Candida, Cryptococcus, and other yeasts in simulated blood culture bottles.

Authors:  T Huahua; J Rudy; C M Kunin
Journal:  J Clin Microbiol       Date:  1991-02       Impact factor: 5.948

7.  Clinical comparison of the resin-containing BACTEC 26 Plus and the Isolator 10 blood culturing systems.

Authors:  J J Tarrand; C Guillot; M Wenglar; J Jackson; J D Lajeunesse; K V Rolston
Journal:  J Clin Microbiol       Date:  1991-10       Impact factor: 5.948

8.  Multicenter comparison of the high volume (10 ml) NR BACTEC PLUS system and the standard (5 ml) NR BACTEC system.

Authors:  F P Koontz; K K Flint; J K Reynolds; S D Allen
Journal:  Diagn Microbiol Infect Dis       Date:  1991 Mar-Apr       Impact factor: 2.803

9.  Impact of the BACTEC NR system in detecting Candida fungemia.

Authors:  P Muñoz; J C Bernaldo de Quirós; J Berenguer; M Rodríguez Créixems; J J Picazo; E Bouza
Journal:  J Clin Microbiol       Date:  1990-03       Impact factor: 5.948

10.  Detection of yeast septicemia by biphasic and radiometric methods.

Authors:  E Prevost; E Bannister
Journal:  J Clin Microbiol       Date:  1981-04       Impact factor: 5.948

View more
  5 in total

1.  Effect of inoculum size on detection of Candida growth by the BACTEC 9240 automated blood culture system using aerobic and anaerobic media.

Authors:  Benjamin J George; Lynn L Horvath; Duane R Hospenthal
Journal:  J Clin Microbiol       Date:  2005-01       Impact factor: 5.948

2.  Guidelines for the investigation of invasive fungal infections in haematological malignancy and solid organ transplantation. British Society for Medical Mycology.

Authors:  D W Denning; E G Evans; C C Kibbler; M D Richardson; M M Roberts; T R Rogers; D W Warnock; R E Warren
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1997-06       Impact factor: 3.267

3.  Controlled comparison of the BACTEC high-blood-volume fungal medium, BACTEC Plus 26 aerobic blood culture bottle, and 10-milliliter isolator blood culture system for detection of fungemia and bacteremia.

Authors:  M L Wilson; T E Davis; S Mirrett; J Reynolds; D Fuller; S D Allen; K K Flint; F Koontz; L B Reller
Journal:  J Clin Microbiol       Date:  1993-04       Impact factor: 5.948

4.  Direct comparison of the BACTEC 9240 and BacT/ALERT 3D automated blood culture systems for candida growth detection.

Authors:  Lynn L Horvath; Benjamin J George; Clinton K Murray; Linda S Harrison; Duane R Hospenthal
Journal:  J Clin Microbiol       Date:  2004-01       Impact factor: 5.948

5.  Detection of simulated candidemia by the BACTEC 9240 system with plus aerobic/F and anaerobic/F blood culture bottles.

Authors:  Lynn L Horvath; Duane R Hospenthal; Clinton K Murray; David P Dooley
Journal:  J Clin Microbiol       Date:  2003-10       Impact factor: 5.948

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.