Literature DB >> 3905850

Large-scale clinical comparison of the lysis-centrifugation and radiometric systems for blood culture.

P Brannon, T E Kiehn.   

Abstract

The Isolator 10 lysis-centrifugation blood culture system (E. I. du Pont de Nemours & Co., Inc., Wilmington, Del.) was compared with the BACTEC radiometric method (Johnston Laboratories, Inc., Towson, Md.) with 6B and 7D broth media for the recovery of bacteria and yeasts. From 11,000 blood cultures, 1,174 clinically significant organisms were isolated. The Isolator system recovered significantly more total organisms, members of the family Enterobacteriaceae, Staphylococcus spp., and yeasts. The BACTEC system recovered significantly more Pseudomonas spp., Streptococcus spp., and anaerobes. Of the Isolator colony counts, 87% measured less than 11 CFU/ml of blood. Organisms, on an average, were detected the same day from each of the two culture systems. Only 13 of the 975 BACTEC isolates (0.01%) were recovered by subculture of growth-index-negative bottles, and 12 of the 13 were detected in another broth blood culture taken within 24 h. Contaminants were recovered from 4.8% of the Isolator 10 and 2.3% of the BACTEC cultures.

Entities:  

Mesh:

Year:  1985        PMID: 3905850      PMCID: PMC271857          DOI: 10.1128/jcm.22.6.951-954.1985

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  13 in total

1.  Evaluation of a lysis-centrifugation system for recovery of yeasts and filamentous fungi from blood.

Authors:  J Bille; L Stockman; G D Roberts; C D Horstmeier; D M Ilstrup
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

2.  Clinical evaluation of a lysis-centrifugation technique for the detection of septicemia.

Authors:  M T Kelly; M F Fojtasek; T M Abbott; D C Hale; J R Dizikes; R Boshard; G E Buck; W J Martin; J M Matsen
Journal:  JAMA       Date:  1983-10-28       Impact factor: 56.272

3.  Clinical laboratory comparison of lysis-centrifugation and BACTEC radiometric blood culture techniques.

Authors:  J C McLaughlin; P Hamilton; J V Scholes; R C Bartlett
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

4.  Evaluation of a lysis-centrifugation and biphasic bottle blood culture system during routine use.

Authors:  M T Kelly; G E Buck; M F Fojtasek
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

5.  Clinical correlations of serial quantitative blood cultures determined by lysis-centrifugation in patients with persistent septicemia.

Authors:  E Whimbey; B Wong; T E Kiehn; D Armstrong
Journal:  J Clin Microbiol       Date:  1984-06       Impact factor: 5.948

6.  Clinical laboratory comparison of the 10-ml isolator blood culture system with BACTEC radiometric blood culture media.

Authors:  J A Kellogg; J P Manzella; J H McConville
Journal:  J Clin Microbiol       Date:  1984-10       Impact factor: 5.948

7.  Improved blood culture technique based on centrifugation: clinical evaluation.

Authors:  G L Dorn; G A Land; G E Wilson
Journal:  J Clin Microbiol       Date:  1979-03       Impact factor: 5.948

8.  Routine aerobic terminal subculturing of blood cultures in a cancer hospital.

Authors:  T E Kiehn; B Wong; F F Edwards; D Armstrong
Journal:  J Clin Microbiol       Date:  1983-10       Impact factor: 5.948

9.  Microbiological and clinical evaluation of the isolator lysis-centrifugation blood culture tube.

Authors:  N K Henry; C A McLimans; A J Wright; R L Thompson; W R Wilson; J A Washington
Journal:  J Clin Microbiol       Date:  1983-05       Impact factor: 5.948

10.  Comparative recovery of bacteria and yeasts from lysis-centrifugation and a conventional blood culture system.

Authors:  T E Kiehn; B Wong; F F Edwards; D Armstrong
Journal:  J Clin Microbiol       Date:  1983-08       Impact factor: 5.948

View more
  34 in total

1.  Nonvalue of antigen detection immunoassays for diagnosis of candidemia.

Authors:  P Phillips; A Dowd; P Jewesson; G Radigan; M G Tweeddale; A Clarke; I Geere; M Kelly
Journal:  J Clin Microbiol       Date:  1990-10       Impact factor: 5.948

2.  Effect of sample volume on yield of positive blood cultures from adult patients with haematological malignancy.

Authors:  D F Brown; R E Warren
Journal:  J Clin Pathol       Date:  1990-09       Impact factor: 3.411

3.  Clinical comparison of Sentinel, a novel blood culture system, with radiometric Bactec 460 and Isolator 10 in the detection of streptococcal and anaerobic bacteraemias.

Authors:  N A Hutchinson; D C Shanson; T Malins
Journal:  J Clin Pathol       Date:  1992-06       Impact factor: 3.411

4.  Methods used in the United Kingdom for the culture of micro-organisms from blood.

Authors:  D F Brown; S F Perry
Journal:  J Clin Pathol       Date:  1992-06       Impact factor: 3.411

5.  Changes in the spectrum of organisms causing bacteremia and fungemia in immunocompromised patients due to venous access devices.

Authors:  T E Kiehn; D Armstrong
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1990-12       Impact factor: 3.267

6.  Isolation of Bartonella (Rochalimaea) henselae: effects of methods of blood collection and handling.

Authors:  S A Brenner; J A Rooney; P Manzewitsch; R L Regnery
Journal:  J Clin Microbiol       Date:  1997-03       Impact factor: 5.948

Review 7.  Bacteraemia in man and animals: an overview.

Authors:  J Vaid
Journal:  Vet Res Commun       Date:  1991       Impact factor: 2.459

8.  Improved recovery of antibiotic-stressed microorganisms on inclusion of saponin in aerobic blood culture media.

Authors:  T S Elliott; C M Stevens; F Macrae; I T Hart; D E Healing; M Palmer; C R Catchpole
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1998-08       Impact factor: 3.267

Review 9.  Bacteremia and fungemia in the immunocompromised patient.

Authors:  T E Kiehn
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

10.  Comparison of Isolator 1.5 and BACTEC NR660 aerobic 6A blood culture systems for detection of fungemia in children.

Authors:  C A Petti; A K Zaidi; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1996-08       Impact factor: 5.948

View more