Literature DB >> 14522572

Intra-aortic balloon counterpulsation in US and non-US centres: results of the Benchmark Registry.

Marc Cohen1, Philip Urban, Jan T Christenson, Debra L Joseph, Robert J Freedman, Michael F Miller, E Magnus Ohman, Ramachandra C Reddy, Gregg W Stone, James J Ferguson.   

Abstract

AIMS: To examine differences in patient characteristics and outcomes in 19636 patients enrolled in the USA and 3027 patients enrolled in other countries undergoing intra-aortic balloon pump (IABP) counterpulsation. METHODS AND
RESULTS: Indications for IABP use; a larger percentage of US patients were identified as 'early support and stabilization for angiography or angioplasty' (21.1% US vs 11.8% non-US), and 'pre-operative support for high-risk CABG' (15.9% vs 6.6%). A smaller percentage of US patients vs non-US patients were identified as 'weaning from cardiopulmonary bypass' (14.3% vs 28.2%), and 'refractory ventricular failure' (6.2% vs 9.8%). One out of five patients in both groups was listed as 'cardiogenic shock' (18.9% US vs 20.2% non-US). All cause, risk-adjusted, in-hospital mortality (20.1% vs 28.7%; P<0.001), and mortality with IABP in place (10.8% vs 18.0%; P<0.001) were lower at US vs non-US sites. In both US and non-US institutions, IABP associated complication rates, such as IABP-related mortality (0.05% vs 0.07%), major limb ischaemia (0.9% vs 0.8%), and severe bleeding (0.9% vs 0.8%), were low.
CONCLUSIONS: IABP counterpulsation is deployed at an earlier clinical stage in US patients. Mortality rates are higher for non-US patients, particularly for patients with non-surgery cardiac interventions, even after adjusting for risk factors. Complication rates were low. Physicians should therefore not be reluctant to use IABP in high-risk patients undergoing cardiac procedures.

Entities:  

Mesh:

Year:  2003        PMID: 14522572     DOI: 10.1016/j.ehj.2003.07.002

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  29 in total

1.  Intraaortic balloon pump: incidence and predictors of complications in the Florence registry.

Authors:  Serafina Valente; Chiara Lazzeri; Elena Crudeli; Marco Chiostri; Cristina Giglioli; Pasquale Bernardo; Gian Franco Gensini
Journal:  Clin Cardiol       Date:  2011-12-06       Impact factor: 2.882

Review 2.  [Intra-aortic balloon pump (IABP) counterpulsation. Do we still need it and if so when?].

Authors:  M Russ
Journal:  Med Klin Intensivmed Notfmed       Date:  2015-09-04       Impact factor: 0.840

3.  Aortic Counterpulsation Therapy in Patients with Advanced Heart Failure: Analysis of the TBRIDGE Registry.

Authors:  Cristiano Guedes Bezerra; Eduardo Leal Adam; Mariana Lins Baptista; Giuliano Serafino Ciambelli; Liliane Kopel; Claudia Bernoche; Leonardo Nicolau Geisler Daud Lopes; Milena Frota Macatrão-Costa; Breno de Alencar Araripe Falcão; Silvia Gelas Lage
Journal:  Arq Bras Cardiol       Date:  2015-12-22       Impact factor: 2.000

Review 4.  Intra-aortic balloon pump counterpulsation in the setting of subarachnoid hemorrhage, cerebral vasospasm, and neurogenic stress cardiomyopathy. Case report and review of the literature.

Authors:  Christos Lazaridis; Gustavo Pradilla; Paul A Nyquist; Rafael J Tamargo
Journal:  Neurocrit Care       Date:  2010-08       Impact factor: 3.210

5.  The need for intra aortic balloon pump support following open heart surgery: risk analysis and outcome.

Authors:  Haralabos Parissis; Michael Leotsinidis; Mohammad Tauqeer Akbar; Efstratios Apostolakis; Dimitrios Dougenis
Journal:  J Cardiothorac Surg       Date:  2010-04-05       Impact factor: 1.637

6.  Safety of intra-aortic balloon pump using glycoprotein IIb/IIIa antagonists.

Authors:  Avishag Laish-Farkash; Hanoch Hod; Shlomo Matetzky; Victor Guetta
Journal:  Clin Cardiol       Date:  2009-02       Impact factor: 2.882

Review 7.  Left to their own devices: breakdowns in United States medical device premarket review.

Authors:  Jonas Zajac Hines; Peter Lurie; Eunice Yu; Sidney Wolfe
Journal:  PLoS Med       Date:  2010-07-13       Impact factor: 11.069

8.  Temporal trends in the use of intraaortic balloon pump associated with percutaneous coronary intervention in the United States, 1998-2008.

Authors:  Hiren Patel; Anupama Shivaraju; Gregg C Fonarow; Hui Xie; Weihua Gao; Adhir R Shroff; Mladen I Vidovich
Journal:  Am Heart J       Date:  2014-06-06       Impact factor: 4.749

9.  How much of the intraaortic balloon volume is displaced toward the coronary circulation?

Authors:  Christina Kolyva; George M Pantalos; John R Pepper; Ashraf W Khir
Journal:  J Thorac Cardiovasc Surg       Date:  2010-01-18       Impact factor: 5.209

10.  Discerning aortic waves during intra-aortic balloon pumping and their relation to benefits of counterpulsation in humans.

Authors:  Christina Kolyva; George M Pantalos; Guruprasad A Giridharan; John R Pepper; Ashraf W Khir
Journal:  J Appl Physiol (1985)       Date:  2009-09-03
View more