Literature DB >> 14516806

Repeatability of an automated Landolt C test, compared with the early treatment of diabetic retinopathy study (ETDRS) chart testing.

Paisan Ruamviboonsuk1, Montip Tiensuwan, Catleya Kunawut, Patcharapim Masayaanon.   

Abstract

PURPOSE: To evaluate the repeatability of visual acuity scores from the automated test and compare them with the Early Treatment of Diabetic Retinopathy Study (ETDRS) chart.
DESIGN: Instrument validation study based on a model of repeatability study in two observations. S
METHODS: a prospective, clinic-based, comparative study. A total of 206 participants without ocular diseases and refractive errors in their right eyes were randomly enrolled in the automated group in which 107 participants performed the automated test and the ETDRS group in which 99 participants read the ETDRS chart. All participants were tested with only their right eyes without corrections at 4 meters and came back to have the same tests 1 week later. The automated test used the Landolt rings as optotypes and was conducted by a low-ended personal computer with a 15-inch monitor and a wireless keyboard. The "letter" score calculated by counting every correct response to optotypes, and the "threshold curve" score interpreted from the optotype size at the midpoint of a visual acuity threshold curve.
RESULTS: The 95% confidence interval of test-retest of visual acuity scores from the automated test are comparable to the ETDRS chart (.143 compared with.125 for letter scores,.145 compared with.122 for threshold curve scores). The score repeatabilities, calculated from the standard deviations of test-retest, from the automated test are also comparable to the ETDRS chart (.201 compared with.177 for letter scores,.206 compared with.172 for threshold curve scores). All comparisons demonstrated no statistical difference (P >.05).
CONCLUSIONS: The automated testing system in this study enables practical measuring visual acuity by the Landolt rings. The system's repeatability, which is comparable to the ETDRS chart, supports its role as an alternative tool for measuring outcome in new clinical research. Its ability to practically generate visual acuity threshold curves may also be useful in future clinical research studies.

Entities:  

Mesh:

Year:  2003        PMID: 14516806     DOI: 10.1016/s0002-9394(03)00394-5

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  12 in total

1.  The dynamics of practice effects in an optotype acuity task.

Authors:  Sven P Heinrich; Katja Krüger; Michael Bach
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-04-21       Impact factor: 3.117

2.  Development and testing of an automated computer tablet-based method for self-testing of high and low contrast near visual acuity in ophthalmic patients.

Authors:  Tariq M Aslam; Neil R A Parry; Ian J Murray; Mahani Salleh; Caterina Dal Col; Naznin Mirza; Gabriela Czanner; Humza J Tahir
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-02-22       Impact factor: 3.117

3.  Visual acuity as measured with Landolt C chart and Early Treatment of Diabetic Retinopathy Study (ETDRS) chart.

Authors:  Hsi-Kung Kuo; Ming-Tse Kuo; Ing-Soo Tiong; Pei-Chang Wu; Yung-Jen Chen; Chih-Hsin Chen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-07-24       Impact factor: 3.117

4.  A computerized resolution visual acuity test in preschool and school age children.

Authors:  Ying-Yan Qin; Zhen-Zhen Liu; Li-Yuan Zhu; Xuan Bao; Fu-Rong Luo; Yi-Zhi Liu; Young Tsau; Ming-Xing Wu
Journal:  Int J Ophthalmol       Date:  2020-02-18       Impact factor: 1.779

5.  Visual function assessment in simulated real-life situations in patients with age-related macular degeneration compared to normal subjects.

Authors:  G Barteselli; M L Gomez; A L Doede; J Chhablani; W Gutstein; D-U Bartsch; L Dustin; S P Azen; W R Freeman
Journal:  Eye (Lond)       Date:  2014-08-01       Impact factor: 3.775

6.  Repeatability of visual acuity testing using a psychometric function.

Authors:  Tomoki Tokutake; Tomofusa Yamauchi; Norihiro Mita; Ken-ichiro Kawamoto; Hitoshi Tabuchi; Kazutaka Kani; Heihachiro Hara; Akio Tabuchi; Hiroshi Sasaki
Journal:  Jpn J Ophthalmol       Date:  2014-05-29       Impact factor: 2.447

7.  Comparison of Snellen and Early Treatment Diabetic Retinopathy Study charts using a computer simulation.

Authors:  Reuben R Shamir; Yael Friedman; Leo Joskowicz; Michael Mimouni; Eytan Z Blumenthal
Journal:  Int J Ophthalmol       Date:  2016-01-18       Impact factor: 1.779

8.  Repeatability and Agreement of Visual Acuity Using the ETDRS Number Chart, Landolt C Chart, or ETDRS Alphabet Chart in Eyes With or Without Sight-Threatening Diseases.

Authors:  Voraporn Chaikitmongkol; Onnisa Nanegrungsunk; Direk Patikulsila; Paisan Ruamviboonsuk; Neil M Bressler
Journal:  JAMA Ophthalmol       Date:  2018-03-01       Impact factor: 7.389

Review 9.  [Monitoring of AMD patients on anti-vascular endothelial growth factor (VEGF) treatment. Practical notes on functional and anatomical examination parameters from drug approval studies, specialist information and case series].

Authors:  C H Meyer; H-M Helb; N Eter
Journal:  Ophthalmologe       Date:  2008-02       Impact factor: 1.059

10.  The Freiburg Visual Acuity Test-variability unchanged by post-hoc re-analysis.

Authors:  Michael Bach
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2007-01-12       Impact factor: 3.535

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.