Literature DB >> 14516333

Nonthoracotomy implantable defibrillator lead extraction: results and comparison with extraction of pacemaker leads.

Eduardo B Saad1, Walid I Saliba, Robert A Schweikert, Ayman S Al-Khadra, Ahmad Abdul-Karim, Mark J Niebauer, Bruce L Wilkoff.   

Abstract

Extraction of pacemaker leads has been demonstrated to be successful and safe in experienced hands using current tools. Whether application of such techniques and tools yield similar results among patients undergoing extraction of nonthoracotomy implantable defibrillator leads is unknown. This report describes a retrospective analysis of indications, techniques used, and outcome of patients who had a single ventricular nonthoracotomy implantable defibrillator lead extracted at The Cleveland Clinic Foundation. Results were compared to a matched population of patients undergoing extraction of ventricular pacemaker leads from a national registry and to the experience with pacemaker lead extraction at The Cleveland Clinic Foundation. Successful complete extraction of ventricular nonthoracotomy implantable defibrillator leads, in the absence of major complications, was achieved in 96.9% of attempts to extract leads from 161 patients. Clinical success was achieved in 98.1% of patients. Failure occurred in three patients. Two patients had major complications, including one death. The most common indication for extraction was infection (46.6%), followed by lead failure (34.2%). Procedure (140.8 vs 171.2 minutes, P<0.01) and fluoroscopy (9.9 vs 11.0 minutes, P<0.01) times compared favorably with those obtained from the pacemaker lead extraction database. Use of LASER did not influence the safety of the procedure or fluoroscopy times. Extraction of ventricular nonthoracotomy implantable defibrillator leads using currently available tools is a complex but effective procedure. In experienced hands, excellent success rates should be achieved with a low incidence of complications.

Entities:  

Mesh:

Year:  2003        PMID: 14516333     DOI: 10.1046/j.1460-9592.2003.00300.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  6 in total

Review 1.  Considerations for cardiac device lead extraction.

Authors:  Oussama Wazni; Bruce L Wilkoff
Journal:  Nat Rev Cardiol       Date:  2016-01-29       Impact factor: 32.419

Review 2.  [ICD lead defects: diagnosis and therapeutical options].

Authors:  Christian G Wollmann; Dirk Böcker; Andreas Löher; Hans H Scheld; Günter Breithardt; Rainer Gradaus
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-02-11

Review 3.  A Questionable Indication For ICD Extraction After Successful VT Ablation.

Authors:  Luca Segreti; Andrea Di Cori; Giulio Zucchelli; Ezio Soldati; Giovanni Coluccia; Stefano Viani; Luca Paperini; Maria Grazia Bongiorni
Journal:  J Atr Fibrillation       Date:  2015-04-30

4.  Safety and Effectiveness of Transvenous Lead Extraction in Patients with Infected Cardiac Resynchronization Therapy Devices; Is It More Risky than Extraction of Other Systems?

Authors:  Paweł Stefańczyk; Dorota Nowosielecka; Anna Polewczyk; Łukasz Tułecki; Konrad Tomków; Wojciech Jacheć; Ewa Lewicka; Andrzej Tomaszewski; Andrzej Kutarski
Journal:  Int J Environ Res Public Health       Date:  2022-05-10       Impact factor: 4.614

5.  Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leads.

Authors:  Maria Grazia Bongiorni; Ezio Soldati; Giulio Zucchelli; Andrea Di Cori; Luca Segreti; Raffaele De Lucia; Gianluca Solarino; Alberto Balbarini; Mario Marzilli; Mario Mariani
Journal:  Eur Heart J       Date:  2008-10-23       Impact factor: 29.983

6.  Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction.

Authors:  Robert G Hauser; William T Katsiyiannis; Charles C Gornick; Adrian K Almquist; Linda M Kallinen
Journal:  Europace       Date:  2009-11-27       Impact factor: 5.214

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.