Literature DB >> 14513454

Reliability of templating in estimating the size of uni-condylar knee arthroplasty.

Venay Bothra1, Gerard Lemon, Derek Lang, David M Smith, Ahmad M Ali.   

Abstract

The use of template systems has aided the preoperative selection of correct prosthetic size during routine arthroplasty. A similar system exists for unicondylar knee arthroplasty. Our goal is to assess the reliability of these templates for preoperatively predicting the correct prosthetic size in unicompartmental knee systems. Ten observers estimated the size of the unicondylar knee prosthesis required for 30 randomly selected patients with osteoarthritis. Estimation of the size was gauged using templates and instructions provided by the manufacturer. The observers worked independently and repeated their measurements 2 weeks later. Intraobserver and interobserver agreement was evaluated using the weighted kappa coefficient, and this revealed poor agreement regardless of the surgeon's experience. This shows that the present system lacks reliability and raises concerns about the place for preoperative radiological templating in unicompartmental knee arthroplasty.

Entities:  

Mesh:

Year:  2003        PMID: 14513454     DOI: 10.1016/s0883-5403(03)00112-8

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty.

Authors:  Daniel Hernandez-Vaquero; Ferran Abat; Juan Sarasquete; Juan Carlos Monllau
Journal:  World J Orthop       Date:  2013-10-18

2.  Unicompartmental knee prosthetization: Which key-points to consider?

Authors:  Andrea Emilio Salvi; Anthony Vatroslav Florschutz
Journal:  World J Orthop       Date:  2013-04-18

3.  Lateral versus medial tibial plateau: morphometric analysis and adaptability with current tibial component design.

Authors:  E Servien; M Saffarini; S Lustig; S Chomel; Ph Neyret
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-09-09       Impact factor: 4.342

4.  Prosthesis size distribution in Oxford phase III unicompartmental knee arthroplasty - Based on more than 1900 Chinese patients.

Authors:  Fang-Xing Wang; Hua-Ming Xue; Tong Ma; Tao Yang; Tao Wen; Yi-Hui Tu
Journal:  J Orthop       Date:  2021-05-16

5.  Implant Overhang after Unicompartmental Knee Arthroplasty: Oxford Prosthesis versus Miller-Galante II Prosthesis.

Authors:  Geon-Hyeong Kim; Bum-Yong Park; Tae-Yong Bae; Kwang-Yun Song; Yong In
Journal:  Knee Surg Relat Res       Date:  2014-05-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.