Literature DB >> 14507755

Development of a clinically feasible logMAR alternative to the Snellen chart: performance of the "compact reduced logMAR" visual acuity chart in amblyopic children.

D A H Laidlaw1, A Abbott, D A Rosser.   

Abstract

BACKGROUND/AIM: The "compact reduced logMAR" (cRLM) chart is being developed as a logMAR alternative to the Snellen chart. It is closer spaced and has fewer letters per line than conventional logMAR charts. Information regarding the performance of such a chart in amblyopes and children is therefore required. This study aimed to investigate the performance of the cRLM chart in amblyopic children.
METHODS: Timed test and retest measurements using two versions of each chart design were obtained on the amblyopic eye of 43 children. Using the methods of Bland and Altman the agreement, test-retest variability (95% confidence limits for agreement, TRV) and test time of the cRLM and the current clinical standard Snellen chart were compared to the gold standard ETDRS logMAR chart.
RESULTS: No systematic bias between chart designs was found. For line assignment scoring the respective TRVs were 0.20 logMAR, 0.20 logMAR, and 0.30 logMAR. Single letter scoring TRVs were cRLM (95% CL 0.17) logMAR, ETDRS (95% CL 0.14) logMAR, and Snellen (95% CL 0.29) logMAR. Median testing times were ETDRS 60 seconds, cRLM 40 seconds, Snellen 30 seconds.
CONCLUSION: The sensitivity to change of the cRLM equalled or approached that of the gold standard ETDRS and was at least 50% better than that of Snellen. This enhanced sensitivity to change was at the cost of only a 10 second time penalty compared to Snellen. The cRLM chart was approximately half the width of the ETDRS chart. The cRLM chart may represent a clinically acceptable compromise between the desire to obtain logMAR acuities of reasonable and known sensitivity to change, chart size, and testing time.

Entities:  

Mesh:

Year:  2003        PMID: 14507755      PMCID: PMC1920770          DOI: 10.1136/bjo.87.10.1232

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  18 in total

1.  The development of a "reduced logMAR" visual acuity chart for use in routine clinical practice.

Authors:  D A Rosser; D A Laidlaw; I E Murdoch
Journal:  Br J Ophthalmol       Date:  2001-04       Impact factor: 4.638

2.  Contour interaction for high and low contrast optotypes in normal and amblyopic observers.

Authors:  A J Simmers; L S Gray; P V McGraw; B Winn
Journal:  Ophthalmic Physiol Opt       Date:  1999-05       Impact factor: 3.117

3.  Improving the reliability of visual acuity measures in young children.

Authors:  P V McGraw; B Winn; L S Gray; D B Elliott
Journal:  Ophthalmic Physiol Opt       Date:  2000-05       Impact factor: 3.117

4.  New test charts for the measurement of visual acuity at far and near distances.

Authors:  L L SLOAN
Journal:  Am J Ophthalmol       Date:  1959-12       Impact factor: 5.258

5.  New design principles for visual acuity letter charts.

Authors:  I L Bailey; J E Lovie
Journal:  Am J Optom Physiol Opt       Date:  1976-11

6.  Validity and reliability of visual acuity measurements.

Authors:  J E Lovie-Kitchin
Journal:  Ophthalmic Physiol Opt       Date:  1988       Impact factor: 3.117

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  New visual acuity charts for clinical research.

Authors:  F L Ferris; A Kassoff; G H Bresnick; I Bailey
Journal:  Am J Ophthalmol       Date:  1982-07       Impact factor: 5.258

Review 9.  Recommended stardard procedures for the clinical measurement and specification of visual acuity. Report of working group 39. Committee on vision. Assembly of Behavioral and Social Sciences, National Research Council, National Academy of Sciences, Washington, D.C.

Authors: 
Journal:  Adv Ophthalmol       Date:  1980

10.  Contour interaction in the preschool child.

Authors:  K D Fern; R E Manny; J R Davis; R R Gibson
Journal:  Am J Optom Physiol Opt       Date:  1986-05
View more
  17 in total

1.  The influence of varying the number of characters per row on the accuracy and reproducibility of the ETDRS visual acuity chart.

Authors:  Reuben R Shamir; Yael G Friedman; Leo Joskowicz; Michael Mimouni; Eytan Z Blumenthal
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-01-07       Impact factor: 3.117

2.  Performance of a computerised visual acuity measurement device in subjects with age-related macular degeneration: comparison with gold standard ETDRS chart measurements.

Authors:  Y Bokinni; N Shah; O Maguire; D A H Laidlaw
Journal:  Eye (Lond)       Date:  2015-06-05       Impact factor: 3.775

3.  Testing vision testing: quantifying the effect of movement on visual acuity measurement.

Authors:  L P Tidbury; A R O'Connor
Journal:  Eye (Lond)       Date:  2014-10-24       Impact factor: 3.775

4.  Validation of printed and computerised crowded Kay picture logMAR tests against gold standard ETDRS acuity test chart measurements in adult and amblyopic paediatric subjects.

Authors:  N Shah; D A H Laidlaw; S Rashid; P Hysi
Journal:  Eye (Lond)       Date:  2011-12-23       Impact factor: 3.775

5.  Prospective evaluation of visual acuity assessment: a comparison of snellen versus ETDRS charts in clinical practice (An AOS Thesis).

Authors:  Peter K Kaiser
Journal:  Trans Am Ophthalmol Soc       Date:  2009-12

6.  Comparison of Snellen and Early Treatment Diabetic Retinopathy Study charts using a computer simulation.

Authors:  Reuben R Shamir; Yael Friedman; Leo Joskowicz; Michael Mimouni; Eytan Z Blumenthal
Journal:  Int J Ophthalmol       Date:  2016-01-18       Impact factor: 1.779

7.  Comparison of visual acuity in macular degeneration patients measured with snellen and early treatment diabetic retinopathy study charts.

Authors:  Iryna A Falkenstein; Denine E Cochran; Stanley P Azen; Laurie Dustin; Ajay M Tammewar; Igor Kozak; William R Freeman
Journal:  Ophthalmology       Date:  2007-08-13       Impact factor: 12.079

Review 8.  [Monitoring of AMD patients on anti-vascular endothelial growth factor (VEGF) treatment. Practical notes on functional and anatomical examination parameters from drug approval studies, specialist information and case series].

Authors:  C H Meyer; H-M Helb; N Eter
Journal:  Ophthalmologe       Date:  2008-02       Impact factor: 1.059

9.  Development and Validation of a Smartphone-Based Visual Acuity Test (Peek Acuity) for Clinical Practice and Community-Based Fieldwork.

Authors:  Andrew Bastawrous; Hillary K Rono; Iain A T Livingstone; Helen A Weiss; Stewart Jordan; Hannah Kuper; Matthew J Burton
Journal:  JAMA Ophthalmol       Date:  2015-08       Impact factor: 7.389

10.  Reliability of a modified logMAR distant visual acuity chart for routine clinical use.

Authors:  Babu Noushad; Jyothi Thomas; Shristi V Amin
Journal:  Oman J Ophthalmol       Date:  2012-05
View more