Literature DB >> 14504828

A prototype small CdTe gamma camera for radioguided surgery and other imaging applications.

Makoto Tsuchimochi1, Harumi Sakahara, Kazuhide Hayama, Minoru Funaki, Ryoichi Ohno, Takashi Shirahata, Terje Orskaug, Gunnar Maehlum, Koki Yoshioka, Einar Nygard.   

Abstract

Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, these probes can provide only radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows visualisation of the size, shape and location of the target tissues. This study is designed to characterise the performance of the SSGC for radioguided surgery of metastatic lesions and for other imaging applications amenable to the smaller format of this prototype imaging system. The detector head had 32 cadmium telluride semiconductor arrays with a total of 1,024 pixels, and with application-specific integrated circuits (ASICs) and a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mmx166 mmx65 mm. The effective visual field was 44.8 mmx44.8 mm. The energy resolution and imaging aspects were tested. Two spherical 5-mm- and 15-mm-diameter technetium-99m radioactive sources that had activities of 0.15 MBq and 100 MBq, respectively, were used to simulate a sentinel lymph node and an injection site. The relative detectability of these foci by the new detector and a conventional scintillation camera was studied. The prototype was also examined in a variety of clinical applications. Energy resolution [full-width at half-maximum (FWHM)] for a single element at the centre of the field of view was 4.2% at 140 keV (99mTc), and the mean energy resolution of the CdTe detector arrays was approximately 7.8%. The spatial resolution, represented by FWHM, had a mean value of 1.56 +/- 0.05 mm. Simulated node foci could be visualised clearly by the SSGC using a 15-s acquisition time. In preliminary clinical tests, the SSGC successfully imaged diseases in a variety of tissues, including salivary and thyroid glands, temporomandibular joints and sentinel lymph nodes. The SSGC has significant potential for diagnosing diseases and facilitating subsequent radioguided surgery.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14504828     DOI: 10.1007/s00259-003-1301-3

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  19 in total

1.  Assessment of bone remodeling in the temporomandibular joint by serial uptake measurement of technetium 99m-labeled methylene diphosphonate with a cadmium telluride probe.

Authors:  W Engelke; M Tsuchimochi; U E Ruttimann; F Hosain
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1991-03

2.  Surgical applications of gamma-detecting probes.

Authors:  W E Burak; M Boso; M O Thurston; E W Martin
Journal:  Surg Technol Int       Date:  1996

3.  Lymphoscintigraphy and radioguided biopsy of the sentinel axillary node in breast cancer.

Authors:  C De Cicco; M Cremonesi; A Luini; M Bartolomei; C Grana; G Prisco; V Galimberti; P Calza; G Viale; U Veronesi; G Paganelli
Journal:  J Nucl Med       Date:  1998-12       Impact factor: 10.057

4.  A method to evaluate intra-operative gamma probes for sentinel lymph node localisation.

Authors:  A J Britten
Journal:  Eur J Nucl Med       Date:  1999-02

5.  Validation of gamma probe detection of the sentinel node in melanoma.

Authors:  B A Kapteijn; O E Nieweg; S H Muller; I H Liem; C A Hoefnagel; E J Rutgers; B B Kroon
Journal:  J Nucl Med       Date:  1997-03       Impact factor: 10.057

6.  Detection of active alveolar bone destruction in human periodontal disease by analysis of radiopharmaceutical uptake after a single injection of 99m-Tc-methylene diphosphonate.

Authors:  M K Jeffcoat; R C Williams; B L Holman; R English; P Goldhaber
Journal:  J Periodontal Res       Date:  1986-11       Impact factor: 4.419

7.  Technetium-99m stannous phytate as an imaging agent for lymph nodes.

Authors:  A Alavi; M M Staum; B F Shesol; P H Bloch
Journal:  J Nucl Med       Date:  1978-04       Impact factor: 10.057

8.  Technical details of intraoperative lymphatic mapping for early stage melanoma.

Authors:  D L Morton; D R Wen; J H Wong; J S Economou; L A Cagle; F K Storm; L J Foshag; A J Cochran
Journal:  Arch Surg       Date:  1992-04

9.  Cadmium telluride matrix gamma camera.

Authors:  J D Allison
Journal:  Med Phys       Date:  1980 May-Jun       Impact factor: 4.071

10.  Studies on focal alveolar bone healing with technetium (Tc)-99m labeled methylene diphosphonate and gold-collimated cadmium telluride probe.

Authors:  M Tsuchimochi; F Hosain; W Engelke; S J Zeichner; U E Ruttimann; R L Webber
Journal:  Oral Surg Oral Med Oral Pathol       Date:  1991-01
View more
  11 in total

Review 1.  Role of sentinel node biopsy in the management and staging of the N0 neck.

Authors:  Gary L Ross; Taimur Shoaib
Journal:  Odontology       Date:  2005-09       Impact factor: 2.634

2.  Radioguided occult lesion localisation in breast cancer using an intraoperative portable gamma camera: first results.

Authors:  P Paredes; S Vidal-Sicart; G Zanón; N Roé; S Rubí; S Lafuente; J Pavía; F Pons
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-11-28       Impact factor: 9.236

3.  Development and characterization of a round hand-held silicon photomultiplier based gamma camera for intraoperative imaging.

Authors:  Kosta Popovic; Jack E McKisson; Brian Kross; Seungjoon Lee; John McKisson; Andrew G Weisenberger; James Proffitt; Alexander Stolin; Stan Majewski; Mark B Williams
Journal:  IEEE Trans Nucl Sci       Date:  2014-05-20       Impact factor: 1.679

4.  Intraoperative radioguidance with a portable gamma camera: a novel technique for laparoscopic sentinel node localisation in urological malignancies.

Authors:  L Vermeeren; R A Valdés Olmos; W Meinhardt; A Bex; H G van der Poel; W V Vogel; F Sivro; C A Hoefnagel; S Horenblas
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03-14       Impact factor: 9.236

5.  Dual-Labeled Near-Infrared/(99m)Tc Imaging Probes Using PAMAM-Coated Silica Nanoparticles for the Imaging of HER2-Expressing Cancer Cells.

Authors:  Haruka Yamaguchi; Makoto Tsuchimochi; Kazuhide Hayama; Tomoyuki Kawase; Norio Tsubokawa
Journal:  Int J Mol Sci       Date:  2016-07-07       Impact factor: 5.923

Review 6.  Cadmium Telluride Semiconductor Detector for Improved Spatial and Energy Resolution Radioisotopic Imaging.

Authors:  Samira Abbaspour; Babak Mahmoudian; Jalil Pirayesh Islamian
Journal:  World J Nucl Med       Date:  2017 Apr-Jun

7.  Intraoperative biophotonic imaging systems for image-guided interventions.

Authors:  Salar Sajedi; Hamid Sabet; Hak Soo Choi
Journal:  Nanophotonics       Date:  2018-12-14       Impact factor: 8.449

8.  Sentinel node detection in head and neck malignancies: innovations in radioguided surgery.

Authors:  L Vermeeren; W M C Klop; M W M van den Brekel; A J M Balm; O E Nieweg; R A Valdés Olmos
Journal:  J Oncol       Date:  2009-11-09       Impact factor: 4.375

9.  Dual-modality imaging with 99mTc and fluorescent indocyanine green using surface-modified silica nanoparticles for biopsy of the sentinel lymph node: an animal study.

Authors:  Makoto Tsuchimochi; Kazuhide Hayama; Michio Toyama; Ichiro Sasagawa; Norio Tsubokawa
Journal:  EJNMMI Res       Date:  2013-04-25       Impact factor: 3.138

10.  Optimization of sentinel lymph node biopsy in breast cancer using an operative gamma camera.

Authors:  Carole Mathelin; Samuel Salvador; Sabrina Croce; Norosoa Andriamisandratsoa; Daniel Huss; Jean-Louis Guyonnet
Journal:  World J Surg Oncol       Date:  2007-11-17       Impact factor: 2.754

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.