Literature DB >> 28286345

Development and characterization of a round hand-held silicon photomultiplier based gamma camera for intraoperative imaging.

Kosta Popovic1, Jack E McKisson2, Brian Kross2, Seungjoon Lee2, John McKisson2, Andrew G Weisenberger2, James Proffitt3, Alexander Stolin4, Stan Majewski5, Mark B Williams6.   

Abstract

This paper describes the development of a hand-held gamma camera for intraoperative surgical guidance that is based on silicon photomultiplier (SiPM) technology. The camera incorporates a cerium doped lanthanum bromide (LaBr3:Ce) plate scintillator, an array of 80 SiPM photodetectors and a two-layer parallel-hole collimator. The field of view is circular with a 60 mm diameter. The disk-shaped camera housing is 75 mm in diameter, approximately 40.5 mm thick and has a mass of only 1.4 kg, permitting either hand-held or arm-mounted use. All camera components are integrated on a mobile cart that allows easy transport. The camera was developed for use in surgical procedures including determination of the location and extent of primary carcinomas, detection of secondary lesions and sentinel lymph node biopsy (SLNB). Here we describe the camera design and its principal operating characteristics, including spatial resolution, energy resolution, sensitivity uniformity, and geometric linearity. The gamma camera has an intrinsic spatial resolution of 4.2 mm FWHM, an energy resolution of 21.1 % FWHM at 140 keV, and a sensitivity of 481 and 73 cps/MBq when using the single- and double-layer collimators, respectively.

Entities:  

Keywords:  Biomedical imaging; Gamma-ray detectors; Instrumentation and measurement

Year:  2014        PMID: 28286345      PMCID: PMC5344198          DOI: 10.1109/TNS.2014.2308284

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  16 in total

1.  A hand-held imaging probe for radio-guided surgery: physical performance and preliminary clinical experience.

Authors:  Stéphanie Pitre; Laurent Ménard; Marcel Ricard; Maurice Solal; Jean-Rémi Garbay; Yves Charon
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-12-17       Impact factor: 9.236

2.  Precise localization of sentinel lymph nodes and estimation of their depth using a prototype intraoperative mini gamma-camera in patients with breast cancer.

Authors:  Carole Mathelin; Samuel Salvador; Daniel Huss; Jean-Louis Guyonnet
Journal:  J Nucl Med       Date:  2007-04       Impact factor: 10.057

3.  Usefulness of a solid-state gamma camera for sentinel node identification in patients with breast cancer.

Authors:  Kazuyoshi Motomura; Atsushi Noguchi; Terumi Hashizume; Yoshihisa Hasegawa; Yoshifumi Komoike; Hideo Inaji; Toshihide Saida; Hiroki Koyama
Journal:  J Surg Oncol       Date:  2005-01-01       Impact factor: 3.454

4.  Radioguided occult lesion localisation in breast cancer using an intraoperative portable gamma camera: first results.

Authors:  P Paredes; S Vidal-Sicart; G Zanón; N Roé; S Rubí; S Lafuente; J Pavía; F Pons
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-11-28       Impact factor: 9.236

5.  Intraoperative gamma imaging of axillary sentinel lymph nodes in breast cancer patients.

Authors:  John N Aarsvod; Carmen M Greene; Robert A Mintzer; Sandra F Grant; Toncred M Styblo; Naomi P Alazraki; Bradley E Patt; Gina M Caravaglia; Joshua Li; Jan S Iwanczyk
Journal:  Phys Med       Date:  2006       Impact factor: 2.685

6.  Radio-guided surgery: advantages of a new portable γ-camera (Sentinella) for intraoperative real time imaging and detection of sentinel lymph nodes in cutaneous malignancies.

Authors:  I Stoffels; T Poeppel; C Boy; S Mueller; F Wichmann; J Dissemond; D Schadendorf; S Rosenbaum-Krumme; J Klode
Journal:  J Eur Acad Dermatol Venereol       Date:  2011-03-23       Impact factor: 6.166

7.  The usefulness of a preoperative compact imager, a hand-held gamma-camera for breast cancer sentinel node biopsy: final results of a prospective double-blind, clinical study.

Authors:  Khaldoun Kerrou; Stéphanie Pitre; Charles Coutant; Roman Rouzier; Pierre-Yves Ancel; Cécile Lebeaux; Virginie Huchet; Françoise Montravers; Odile Pascal; Marie-Alix Duval; Françoise Lefebvre; Laurent Menard; Serge Uzan; Yves Charon; Emmanuel Barranger
Journal:  J Nucl Med       Date:  2011-08-17       Impact factor: 10.057

8.  Intraoperative imaging guidance for sentinel node biopsy in melanoma using a mobile gamma camera.

Authors:  Lynn T Dengel; Mitali J More; Patricia G Judy; Gina R Petroni; Mark E Smolkin; Patrice K Rehm; Stan Majewski; Mark B Williams; Craig L Slingluff
Journal:  Ann Surg       Date:  2011-04       Impact factor: 12.969

9.  Intraoperative radioguidance with a portable gamma camera: a novel technique for laparoscopic sentinel node localisation in urological malignancies.

Authors:  L Vermeeren; R A Valdés Olmos; W Meinhardt; A Bex; H G van der Poel; W V Vogel; F Sivro; C A Hoefnagel; S Horenblas
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03-14       Impact factor: 9.236

10.  A new intraoperative gamma camera for the sentinel lymph node procedure in breast cancer.

Authors:  Carole Mathelin; Samuel Salvador; Virgile Bekaert; Sabrina Croce; Norosoa Andriamisandratsoa; Philippe Liégeois; Eric Prados; Jean-Louis Guyonnet; Daniel Grucker; David Brasse
Journal:  Anticancer Res       Date:  2008 Sep-Oct       Impact factor: 2.480

View more
  1 in total

1.  Evaluation of camera-based freehand SPECT in preoperative sentinel lymph node mapping for melanoma patients.

Authors:  Annie K Kogler; Andrew M Polemi; Surabhi Nair; Stanislaw Majewski; Lynn T Dengel; Craig L Slingluff; Brian Kross; S J Lee; J E McKisson; John McKisson; Andrew G Weisenberger; Benjamin L Welch; Thomas Wendler; Philipp Matthies; Joerg Traub; Michael Witt; Mark B Williams
Journal:  EJNMMI Res       Date:  2020-11-11       Impact factor: 3.138

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.