Literature DB >> 14500236

Computer-aided detection (CAD) in screening mammography: sensitivity of commercial CAD systems for detecting architectural distortion.

Jay A Baker1, Eric L Rosen, Joseph Y Lo, Edgardo I Gimenez, Ruth Walsh, Mary Scott Soo.   

Abstract

OBJECTIVE: Computer-aided detection (CAD) algorithms have successfully revealed breast masses and microcalcifications on screening mammography. The purpose of our study was to evaluate the sensitivity of commercially available CAD systems for revealing architectural distortion, the third most common appearance of breast cancer.
MATERIALS AND METHODS: Two commercially available CAD systems were used to evaluate screening mammograms obtained in 43 patients with 45 mammographically detected regions of architectural distortion. For each CAD system, we determined the sensitivity for revealing architectural distortion on at least one image of the two-view mammographic examination (case sensitivity) and for each individual mammogram (image sensitivity). Surgical biopsy results were available for each case of architectural distortion.
RESULTS: Architectural distortion was deemed present and actionable by a panel of expert breast imagers in 80 views of the 45 cases. One CAD system detected distortion in 22 of 45 cases of distortion (case sensitivity, 49%) and in 30 of 80 mammograms (image sensitivity, 38%); it displayed 0.7 false-positive marks per image. Another CAD system identified distortion in 15 of 45 cases (case sensitivity, 33%) and 17 of 80 mammograms (image sensitivity, 21%); it displayed 1.27 false-positive marks per image. Sensitivity for malignancy-caused distortion was similar to or lower than sensitivity for all causes of distortion.
CONCLUSION: Fewer than one half of the cases of architectural distortion were detected by the two most widely available CAD systems used for interpretations of screening mammograms. Considerable improvement in the sensitivity of CAD systems is needed for detecting this type of lesion. Practicing breast imagers who use CAD systems should remain vigilant for architectural distortion.

Entities:  

Mesh:

Year:  2003        PMID: 14500236     DOI: 10.2214/ajr.181.4.1811083

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  24 in total

1.  Consensus versus disagreement in imaging research: a case study using the LIDC database.

Authors:  Dmitriy Zinovev; Yujie Duo; Daniela S Raicu; Jacob Furst; Samuel G Armato
Journal:  J Digit Imaging       Date:  2012-06       Impact factor: 4.056

2.  Measures of angular spread and entropy for the detection of architectural distortion in prior mammograms.

Authors:  Shantanu Banik; Rangaraj M Rangayyan; J E Leo Desautels
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-03-30       Impact factor: 2.924

3.  Detection of architectural distortion in prior mammograms via analysis of oriented patterns.

Authors:  Rangaraj M Rangayyan; Shantanu Banik; J E Leo Desautels
Journal:  J Vis Exp       Date:  2013-08-30       Impact factor: 1.355

Review 4.  Colonoscopy vs CT colonography to screen for colorectal neoplasia in average-risk patients.

Authors:  J M Hardacre; J L Ponsky; M E Baker
Journal:  Surg Endosc       Date:  2005-03       Impact factor: 4.584

5.  Impact of breast density on computer-aided detection in full-field digital mammography.

Authors:  Silvia Obenauer; Christian Sohns; Carola Werner; Eckhardt Grabbe
Journal:  J Digit Imaging       Date:  2006-09       Impact factor: 4.056

Review 6.  CAD for mammography: the technique, results, current role and further developments.

Authors:  Ansgar Malich; Dorothee R Fischer; Joachim Böttcher
Journal:  Eur Radiol       Date:  2006-01-17       Impact factor: 5.315

7.  Gabor filters and phase portraits for the detection of architectural distortion in mammograms.

Authors:  Rangaraj M Rangayyan; Fábio J Ayres
Journal:  Med Biol Eng Comput       Date:  2006-08-11       Impact factor: 2.602

8.  A pilot study of architectural distortion detection in mammograms based on characteristics of line shadows.

Authors:  Mitsutaka Nemoto; Soshi Honmura; Akinobu Shimizu; Daisuke Furukawa; Hidefumi Kobatake; Shigeru Nawano
Journal:  Int J Comput Assist Radiol Surg       Date:  2008-10-28       Impact factor: 2.924

9.  Characterizing Architectural Distortion in Mammograms by Linear Saliency.

Authors:  Fabián Narváez; Jorge Alvarez; Juan D Garcia-Arteaga; Jonathan Tarquino; Eduardo Romero
Journal:  J Med Syst       Date:  2016-12-22       Impact factor: 4.460

Review 10.  State of the art of current modalities for the diagnosis of breast lesions.

Authors:  Cosimo Di Maggio
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-04-15       Impact factor: 9.236

View more