Two-dimensional arrays for medical ultrasound.

S W Smith1, G E Trahey, O T von Ramm.   

Abstract

The design, fabrication and evaluation of two-dimensional transducer arrays are described for medical ultrasound imaging. A 4 x 32, 2.8 MHz array was developed to use new signal processing techniques for improved B-scan imaging including elevation focusing, phase correction and synthetic aperture imaging. Laboratory measurements from typical array elements showed 50 omega insertion loss of -56 dB, -6 dB fractional bandwidth of 43%, interelement crosstalk of -19 dB, and -6 dB pulse-echo angular response of 62 degrees. Simulations of pulse-echo beam plots have shown grating lobes 20 dB below the main lobe at +/- 7 degrees in the elevation direction. The complete 2-D array has been used for measurements of phase aberrations in breast, and the individual 32 element linear arrays have been used to obtain conventional B-scans. Several 16 x 16 arrays have also been developed for high speed volumetric imaging. These include 96 transmit elements and 32 receive channels. With a lambda/4 matching layer, laboratory measurements show 50 omega insertion loss of -72 dB, -6 dB fractional bandwidth of 63%, interelement crosstalk of -29 dB and -6 dB angular response of 25 degrees. Pulse-echo sensitivity was improved by 21 dB through the use of integrated circuit preamplifiers of high impedance mounted in the transducer handle. In vivo cardiac, abdominal, and obstetric B-scans with elevation focusing, as well as high speed C-scans, have been obtained with these 2-D arrays.

Mesh:

Year:  1992        PMID: 1448889     DOI: 10.1177/016173469201400301

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  13 in total

Review 1.  Intracardiac echocardiography: computerized detection of left ventricular borders.

Authors:  M Sonka; W Liang; P Kanani; J Allan; S DeJong; R Kerber; C McKay
Journal:  Int J Card Imaging       Date:  1998-12

2.  Volumetric Hall effect tomography--a feasibility study.

Authors:  H Wen
Journal:  Ultrason Imaging       Date:  1999-07       Impact factor: 1.578

3.  Applications of 2-dimensional matrix array for 3- and 4-dimensional examination of the fetus: a pictorial essay.

Authors:  Luís F Gonçalves; Jimmy Espinoza; Juan Pedro Kusanovic; Wesley Lee; Jyh Kae Nien; Joaquin Santolaya-Forgas; Giancarlo Mari; Marjorie C Treadwell; Roberto Romero
Journal:  J Ultrasound Med       Date:  2006-06       Impact factor: 2.153

4.  Three-dimensional ultrasound scanning.

Authors:  Aaron Fenster; Grace Parraga; Jeff Bax
Journal:  Interface Focus       Date:  2011-06-01       Impact factor: 3.906

5.  Co-Integrated PIN-PMN-PT 2-D Array and Transceiver Electronics by Direct Assembly Using a 3-D Printed Interposer Grid Frame.

Authors:  Robert Wodnicki; Haochen Kang; Ruimin Chen; Nestor E Cabrera-Munoz; Hayong Jung; Laiming Jiang; Josquin Foiret; Yu Liu; Victoria Chiu; Douglas N Stephens; Qifa Zhou; Katherine W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-09-30       Impact factor: 2.725

Review 6.  Recent developments in vascular ultrasound technology.

Authors:  P R Hoskins; D A Kenwright
Journal:  Ultrasound       Date:  2015-03-26

Review 7.  Secondary Stroke Prevention: Improving Diagnosis and Management with Newer Technologies.

Authors:  Yahia Z Imam; Atlantic D'Souza; Rayaz A Malik; Ashfaq Shuaib
Journal:  Transl Stroke Res       Date:  2016-09-02       Impact factor: 6.829

8.  Short-lag Spatial Coherence Imaging in 1.5-D and 1.75-D Arrays: Elevation Performance and Array Design Considerations.

Authors:  Matthew R Morgan; Dongwoon Hyun; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-03-20       Impact factor: 2.725

9.  Real-time 3-D ultrasound guidance of interventional devices.

Authors:  Edward D Light; John F Angle; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-09       Impact factor: 2.725

10.  Short-lag spatial coherence imaging on matrix arrays, part II: Phantom and in vivo experiments.

Authors:  Marko Jakovljevic; Brett C Byram; Dongwoon Hyun; Jeremy J Dahl; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-07       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.