Literature DB >> 1433547

Early experience with the controlled girth and length expanding cylinder of the American Medical Systems Ultrex penile prosthesis.

D K Montague1, M M Lakin.   

Abstract

A prospective study was done to evaluate length expansion characteristics of the AMS Ultrex penile prosthesis cylinder intraoperatively and in the early postoperative period. A total of 50 patients 30 to 74 years old (mean age 55.2 years) underwent implantation of this device. Intraoperative changes in the pubis to mid glans distance between deflation and inflation ranged from 1 to 4 cm. (mean 1.9). Postoperative followup measurements were obtained in 46 patients at 1 to 15 months (mean 4). There was a 1 cm. decrease in the amount of postoperative length expansion for 6 patients, while length expansion increased by 1 cm. for 12 and for 28 the postoperative length expansion was the same as the intraoperative length expansion.

Entities:  

Mesh:

Year:  1992        PMID: 1433547     DOI: 10.1016/s0022-5347(17)36933-1

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  8 in total

1.  Penile prosthesis implantation for end-stage erectile dysfunction after radical prostatectomy.

Authors:  Drogo K Montague
Journal:  Rev Urol       Date:  2005

2.  Nonpharmacologic treatment of erectile dysfunction.

Authors:  Drogo K Montague
Journal:  Rev Urol       Date:  2002

3.  Increasing size with penile implants.

Authors:  Drogo K Montague; Kenneth W Angermeier
Journal:  Curr Urol Rep       Date:  2008-11       Impact factor: 3.092

4.  Implantation of AMS 700 LGX penile prosthesis preserves penile length without the need for penile lengthening procedures.

Authors:  Carlo Luigi Augusto Negro; Matteo Paradiso; Alessandro Rocca; Franco Bardari
Journal:  Asian J Androl       Date:  2016 Jan-Feb       Impact factor: 3.285

Review 5.  Penile prosthesis implant: scientific advances and technological innovations over the last four decades.

Authors:  Eric Chung
Journal:  Transl Androl Urol       Date:  2017-02

Review 6.  Current status of penile prosthesis implantation.

Authors:  D K Montague; K W Angermeier
Journal:  Curr Urol Rep       Date:  2000-12       Impact factor: 2.862

Review 7.  Penile prosthesis surgery in the management of erectile dysfunction.

Authors:  Hossein Sadeghi-Nejad; Mina Fam
Journal:  Arab J Urol       Date:  2013-07-02

8.  Patient satisfaction and penile morphology changes with postoperative penile rehabilitation 2 years after Coloplast Titan prosthesis.

Authors:  Michael B Pryor; Rafael Carrion; Run Wang; Gerard Henry
Journal:  Asian J Androl       Date:  2016 Sep-Oct       Impact factor: 3.285

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.