Literature DB >> 16985898

Penile prosthesis implantation for end-stage erectile dysfunction after radical prostatectomy.

Drogo K Montague.   

Abstract

When erectile dysfunction occurs after radical prostatectomy and phosphodiesterase-5 inhibitor therapy fails, second-line therapies such as vacuum constriction devices, intraurethral prostaglandins, and penile injection therapy should be offered. When second-line therapies are not effective or acceptable to the man and his partner, penile prosthesis implantation becomes the treatment of choice. Today's 3-piece inflatable devices offer flaccidity and erection that approach the natural state. Design improvements have resulted in devices that have freedom from mechanical failure ranging from 92% to 94%. Antibiotic and hydrophilic coatings have reduced infection rates.

Entities:  

Year:  2005        PMID: 16985898      PMCID: PMC1477598     

Source DB:  PubMed          Journal:  Rev Urol        ISSN: 1523-6161


  21 in total

1.  Early experience with the controlled girth and length expanding cylinder of the American Medical Systems Ultrex penile prosthesis.

Authors:  D K Montague; M M Lakin
Journal:  J Urol       Date:  1992-11       Impact factor: 7.450

2.  Patient and partner satisfaction with the AMS 700 penile prosthesis.

Authors:  R H McLaren; D M Barrett
Journal:  J Urol       Date:  1992-01       Impact factor: 7.450

3.  Long-term mechanical reliability of AMS 700 series inflatable penile prostheses: comparison of CX/CXM and Ultrex cylinders.

Authors:  J A Daitch; K W Angermeier; M M Lakin; B J Ingleright; D K Montague
Journal:  J Urol       Date:  1997-10       Impact factor: 7.450

4.  A prospective study measuring penile length in men treated with radical prostatectomy for prostate cancer.

Authors:  Marc Savoie; Sandy S Kim; Mark S Soloway
Journal:  J Urol       Date:  2003-04       Impact factor: 7.450

Review 5.  Radical prostatectomy, preservation of sexual function, cancer control. The controversy.

Authors:  P C Walsh
Journal:  Urol Clin North Am       Date:  1987-11       Impact factor: 2.241

6.  Mechanical reliability and safety of, and patient satisfaction with the Ambicor inflatable penile prosthesis: results of a 2 center study.

Authors:  L A Levine; C R Estrada; A Morgentaler
Journal:  J Urol       Date:  2001-09       Impact factor: 7.450

7.  The hydrophilic-coated inflatable penile prosthesis: 1-year experience.

Authors:  Christopher E Wolter; Wayne J G Hellstrom
Journal:  J Sex Med       Date:  2004-09       Impact factor: 3.802

8.  Penile fibrosis in intracavernosal prostaglandin E1 injection therapy for erectile dysfunction.

Authors:  K K Chew; B G Stuckey; C M Earle; S S Dhaliwal; E J Keogh
Journal:  Int J Impot Res       Date:  1997-12       Impact factor: 2.896

9.  Prospective long-term results and quality-of-life assessment after Dura-II penile prosthesis placement.

Authors:  Kenneth H Ferguson; R Duane Cespedes
Journal:  Urology       Date:  2003-02       Impact factor: 2.649

10.  Efficacy of antibiotic impregnation of inflatable penile prostheses in decreasing infection in original implants.

Authors:  Culley C Carson
Journal:  J Urol       Date:  2004-04       Impact factor: 7.450

View more
  7 in total

1.  Penile prosthesis implantation for the treatment for male erectile dysfunction: clinical outcomes and lessons learnt after 955 procedures.

Authors:  E Chung; C T Van; I Wilson; R A Cartmill
Journal:  World J Urol       Date:  2012-03-29       Impact factor: 4.226

2.  [Interdisciplinary and individualized therapy of prostate cancer : International prostate cancer symposium Bonn 2013 - challenges and targets].

Authors:  M Schwardt; J Debus; G Feick; B Hadaschik; M Hohenfellner; R Schüle; J-P Zacharias; S E Combs
Journal:  Urologe A       Date:  2015-11       Impact factor: 0.639

Review 3.  Optimizing Outcomes in the Virgin Penile Implant Patient.

Authors:  Charles Welliver
Journal:  Curr Urol Rep       Date:  2019-02-07       Impact factor: 3.092

4.  Comparison of patient satisfaction rates for the malleable and two piece-inflatable penile prostheses.

Authors:  Hakan Kılıçarslan; Yurdaer Kaynak; Kaan Gökcen; Burhan Coşkun; Onur Kaygısız
Journal:  Turk J Urol       Date:  2014-12

5.  Sustainable long-term results on postoperative sexual activity after radical prostatectomy when a clinical sexologist is included in the sexual rehabilitation process. A retrospective study on 7 years postoperative outcome.

Authors:  Peter Stroberg; Christina Ljunggren; Amir Sherif
Journal:  Cent European J Urol       Date:  2020-10-31

6.  Improvement in sexual function after robot-assisted radical prostatectomy: A rehabilitation program with involvement of a clinical sexologist.

Authors:  Christina Ljunggren; Peter Ströberg
Journal:  Cent European J Urol       Date:  2015-05-04

7.  Patient satisfaction and penile morphology changes with postoperative penile rehabilitation 2 years after Coloplast Titan prosthesis.

Authors:  Michael B Pryor; Rafael Carrion; Run Wang; Gerard Henry
Journal:  Asian J Androl       Date:  2016 Sep-Oct       Impact factor: 3.285

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.