Using the orthodontic measuring and simulation system (OMSS), the deactivation behaviour of diverse orthodontic levelling arches was investigated. The vertical forces and uprighting moments, as also the levelling effectiveness for initial malalignments of tooth 21 (1 mm and 2 mm infraocclusion, 20 degrees angulation) were measured, with the influence of various ligatures used in clinical practice being taken into account. The results may be summarized as follows: In the case of a large vertical offset (infraocclusion) the vertical forces can attain values of up to 3.8 N, depending on the type of levelling arch used. On deactivation, we can observe a sharp decrease in force caused by the frictional resistance between bracket and arch wire, which has to be overcome by the wire. The loss of desired force caused by friction may be as much as 50%, and is determined by the arch wire, bracket and mode of ligation. A smaller vertical offset (infraocclusion) (1 mm) is associated with extrusive forces of 0.2 N--0.8 N. Using looped levelling arches made of 0.016" standard steel wire, there is no frictional loss of orthodontic force, so that the highest vertical forces (more than 3.0 N) are observed with these arch wires. With an initial angulation of the tooth of about 20 degrees, uprighting moments of between 3.0 Nmm and 33.0 Nmm are measured, the looped arches again generating the highest moments. To ensure adequate uprighting moments in a combination of vertical offset (infraocclusion) and angulation, very high extrusive forces must be accepted. As a dynamic analysis of the tooth movement with the OMSS shows, the use of a specific arch wire results in a typical levelling defect. There is no general correlation between extrusive force or uprighting moment and the levelling effectiveness of an orthodontic arch. It is not possible to recommend a particular levelling arch.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1427539     DOI: 10.1007/bf02325076

Source DB:  PubMed          Journal:  Fortschr Kieferorthop        ISSN: 0015-816X


  13 in total

1.  [The effect of physiological tooth mobility on the friction between the bracket and the arch].

Authors:  P Jost-Brinkmann; R R Miethke
Journal:  Fortschr Kieferorthop       Date:  1991-04

2.  Examination of Chinese NiTi wire by a combined clinical and laboratory approach.

Authors:  B Mohlin; H Müller; J Odman; B Thilander
Journal:  Eur J Orthod       Date:  1991-10       Impact factor: 3.075

3.  Application of the orthodontic measurement and simulation system (OMSS) in orthodontics.

Authors:  D Drescher; C Bourauel; M Thier
Journal:  Eur J Orthod       Date:  1991-06       Impact factor: 3.075

4.  [The effect of the ligature on the friction between bracket and arch].

Authors:  H A Schumacher; C Bourauel; D Drescher
Journal:  Fortschr Kieferorthop       Date:  1990-04

5.  Triple-stranded stainless steel wires--evaluation of mechanical properties and comparison with titanium alloy alternatives.

Authors:  R P Kusy; L E Stevens
Journal:  Angle Orthod       Date:  1987-01       Impact factor: 2.079

6.  Effects of brackets and ties on stiffness of an arch wire.

Authors:  D M Adams; J M Powers; K Asgar
Journal:  Am J Orthod Dentofacial Orthop       Date:  1987-02       Impact factor: 2.650

7.  Effects of composition and cross section on the elastic properties of orthodontic wires.

Authors:  R P Kusy; A R Greenberg
Journal:  Angle Orthod       Date:  1981-10       Impact factor: 2.079

8.  Variable-modulus orthodontics.

Authors:  C J Burstone
Journal:  Am J Orthod       Date:  1981-07

9.  Arch leveling and alignment effectiveness of two types of wire (II): a graphic interpretation.

Authors:  G Andreasen; J Murray; J Fahl
Journal:  Quintessence Int Dent Dig       Date:  1984-02

10.  The flexure modulus of elasticity of orthodontic wires.

Authors:  A J Goldberg; J Morton; C J Burstone
Journal:  J Dent Res       Date:  1983-07       Impact factor: 6.116

View more
  9 in total

1.  First order couples induced by nickel-titanium archwires featuring an electrochemically refined surface during simulated rotation of teeth.

Authors:  Leif Johannessen; Ludger Keilig; Susanne Reimann; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2013-03-08       Impact factor: 1.938

2.  Different bracket-archwire combinations for simulated correction of two-dimensional tooth malalignment: Leveling outcomes and initial force systems.

Authors:  Sue Holtmann; Anna Konermann; Ludger Keilig; Susanne Reimann; Andreas Jäger; Mona Montasser; Tarek El-Bialy; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2014-10-26       Impact factor: 1.938

3.  Effect of archwire qualities and bracket designs on the force systems during leveling of malaligned teeth.

Authors:  W Perrey; A Konermann; L Keilig; S Reimann; A Jäger; C Bourauel
Journal:  J Orofac Orthop       Date:  2015-03       Impact factor: 1.938

4.  [The force level of pseudoelastic leveling wires in relation to interbracket distance].

Authors:  D Segner
Journal:  Fortschr Kieferorthop       Date:  1995-01

5.  The leveling effectiveness of self-ligating and conventional brackets for complex tooth malalignments.

Authors:  Magali Fansa; Ludger Keilig; Susanne Reimann; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2009-08-02       Impact factor: 1.938

6.  Alignment efficiency of superelastic coaxial nickel-titanium vs superelastic single-stranded nickel-titanium in relieving mandibular anterior crowding: a randomized controlled prospective study.

Authors:  Biju Sebastian
Journal:  Angle Orthod       Date:  2011-10-19       Impact factor: 2.079

7.  Efficiency, behavior, and clinical properties of superelastic NiTi versus multistranded stainless steel wires: a prospective clinical trial.

Authors:  Satpal S Sandhu; V Surendra Shetty; Subraya Mogra; Joseph Varghese; Jasleen Sandhu; Jagpreet S Sandhu
Journal:  Angle Orthod       Date:  2012-01-06       Impact factor: 2.079

8.  Comparative Analysis of Periodontal Pain According to the Type of Precision Orthodontic Appliances: Vestibular, Lingual and Aligners. A Prospective Clinical Study.

Authors:  Laura Antonio-Zancajo; Javier Montero; Daniele Garcovich; Mario Alvarado-Lorenzo; Alberto Albaladejo; Alfonso Alvarado-Lorenzo
Journal:  Biology (Basel)       Date:  2021-04-28

9.  A randomized clinical trial investigating pain associated with superelastic nickel-titanium and multistranded stainless steel archwires during the initial leveling and aligning phase of orthodontic treatment.

Authors:  Satpal Singh Sandhu; Jasleen Sandhu
Journal:  J Orthod       Date:  2013-12
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.