Examination of Chinese NiTi wire by a combined clinical and laboratory approach.

B Mohlin1, H Müller, J Odman, B Thilander.   

Abstract

Chinese NiTi wire was compared with Nitinol and stainless steel wires in a combined laboratory and clinical examination. In the laboratory test, the loading and unloading-deflection properties of the wires were determined in a three-point bending test and their surface properties were studied in a scanning electron microscope. This test attempts to simulate a common clinical situation. The NiTi material showed a non-linear force-deflection relationship. The increase in force from 1 mm deflection and onwards was very slow and the force delivered during unloading from large deflections was almost constant. This behaviour was somewhat different for smaller downward deflections of NiTi wires. Plastic deformation was insignificant. The clinical study confirmed the laboratory results obtained, characterizing a wire material much superior to stainless steel and even superior to Nitinol for alignment purposes. In clinical use, however, the rate of fractures of NiTi wires turned out to be unsatisfactorily high. This disadvantage was not predicted by the three-point bending test. Scanning electron microscopy revealed surface defects and non-metallic inclusions in fractured NiTi wires. A combination of a bending test simulating a clinical situation and surface examination is recommended when new wire materials are to be tested.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1748186     DOI: 10.1093/ejo/13.5.386

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  6 in total

1.  [The deactivation behavior and effectiveness of different orthodontic leveling arches--a dynamic analysis of the force systems].

Authors:  H A Schumacher; C Bourauel; D Drescher
Journal:  Fortschr Kieferorthop       Date:  1992-10

2.  Effect of archwire qualities and bracket designs on the force systems during leveling of malaligned teeth.

Authors:  W Perrey; A Konermann; L Keilig; S Reimann; A Jäger; C Bourauel
Journal:  J Orofac Orthop       Date:  2015-03       Impact factor: 1.938

3.  Mechanical properties of NiTi and CuNiTi wires used in orthodontic treatment. Part 2: Microscopic surface appraisal and metallurgical characteristics.

Authors:  Marco Abdo Gravina; Cristiane Canavarro; Carlos Nelson Elias; Maria das Graças Afonso Miranda Chaves; Ione Helena Vieira Portella Brunharo; Cátia Cardoso Abdo Quintão
Journal:  Dental Press J Orthod       Date:  2014 Jan-Feb

4.  Impact of recycling on the mechanical properties of nickel-titanium alloy wires and the efficacy of their reuse after cold sterilization.

Authors:  Ankit Yadav; Poonam K Jayaprakash; Rajeshwar Singh; Meeta Dawer; Palash Modi; Bhumika Sehdev; Kiran K Ganji
Journal:  J Orthod Sci       Date:  2020-08-18

5.  Variations in surface roughness of seven orthodontic archwires: an SEM-profilometry study.

Authors:  Fariborz Amini; Vahid Rakhshan; Maryam Pousti; Hajir Rahimi; Mahsa Shariati; Bahareh Aghamohamadi
Journal:  Korean J Orthod       Date:  2012-06-28       Impact factor: 1.372

6.  Comparison of mechanical properties of beta-titanium wires between leveled and unleveled brackets: an in vitro study.

Authors:  Natalia Martins Insabralde; Thaís Poletti; Ana Cláudia Conti; Paula Vanessa Oltramari-Navarro; Murilo B Lopes; Carlos Flores-Mir; Marcio Rodrigues de Almeida
Journal:  Prog Orthod       Date:  2014-05-30       Impact factor: 2.750