Literature DB >> 6942654

Variable-modulus orthodontics.

C J Burstone.   

Abstract

Traditionally, orthodontists have varied the size of the wire in order to produce a range of light to heavy forces. A new approach to force control in presented which allows wire size to remain relatively constant and the material of the wire is selected on the basis of clinical requirements. When the material instead of the cross section is varied, superior orientation should be achieved with fewer wires during tooth alignment, and bracket-wire play becomes independent of the forces needed. Since wire stiffness is determined by wire corss section and material, a simplified numbering system is described which aids clinicians in evaluating any orthodontic wire.

Mesh:

Substances:

Year:  1981        PMID: 6942654     DOI: 10.1016/0002-9416(81)90192-5

Source DB:  PubMed          Journal:  Am J Orthod        ISSN: 0002-9416


  32 in total

1.  [The deactivation behavior and effectiveness of different orthodontic leveling arches--a dynamic analysis of the force systems].

Authors:  H A Schumacher; C Bourauel; D Drescher
Journal:  Fortschr Kieferorthop       Date:  1992-10

2.  Frictional characteristics of composite orthodontic archwires against stainless steel and ceramic brackets in the passive and active configurations.

Authors:  S W Zufall; K C Kennedy; R P Kusy
Journal:  J Mater Sci Mater Med       Date:  1998-11       Impact factor: 3.896

3.  Variation in flexural properties of photo-pultruded composite archwires: analyses of round and rectangular profiles.

Authors:  D W Fallis; R P Kusy
Journal:  J Mater Sci Mater Med       Date:  2000-11       Impact factor: 3.896

4.  [An in-vitro study of the use of palatal arches in controlling the position of the upper molars].

Authors:  A Jäger; J Planert; H Modler; L Gripp
Journal:  Fortschr Kieferorthop       Date:  1992-08

5.  [The effect of physiological tooth mobility on the friction between the bracket and the arch].

Authors:  P Jost-Brinkmann; R R Miethke
Journal:  Fortschr Kieferorthop       Date:  1991-04

6.  [The materials engineering characteristics of orthodontic nickel-titanium wires].

Authors:  D Drescher; C Bourauel; M Thier
Journal:  Fortschr Kieferorthop       Date:  1990-12

7.  Surgical-orthodontic management of bilateral multiple impactions in non-syndromic patient.

Authors:  Jiwanasha Manish Agrawal; Manish Suresh Agrawal; Lalita Girish Nanjannawar
Journal:  BMJ Case Rep       Date:  2013-01-17

8.  [New wires and their force delivery--consequences for orthodontic therapy].

Authors:  H P Bantleon; H Droschl; K P Pfeiffer
Journal:  Fortschr Kieferorthop       Date:  1989-08

9.  Symmetric and asymmetric expansion of molars using a Burstone-type transpalatal arch. Biomechanical and clinical analysis.

Authors:  Michaela Tsetsilas; Anna-Christin Konermann; Ludger Keilig; Susanne Reimann; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2015-09       Impact factor: 1.938

10.  Evaluation of the load system produced by a single intrusion bend in a maxillary lateral incisor bracket with different alloys.

Authors:  Ricardo Lima Shintcovsk; Roberto Soares da Silva Júnior; Larry White; Lidia Parsekian Martins; Renato Parsekian Martins
Journal:  Angle Orthod       Date:  2018-05-15       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.