Literature DB >> 14156570

EFFECT OF NITROUS OXIDE AND OF NARCOTIC PREMEDICATION ON THE ALVEOLAR CONCENTRATION OF HALOTHANE REQUIRED FOR ANESTHESIA.

L J SAIDMAN, E I EGER.   

Abstract

Entities:  

Keywords:  ANESTHESIA, INHALATION; CLINICAL RESEARCH; ELECTRIC STIMULATION; ELECTROPHYSIOLOGY; HALOTHANE; LUNG; MORPHINE; NITROUS OXIDE; OXYGEN; PHYSIOLOGY; PREANESTHETIC MEDICATION; RESPIRATION, ARTIFICIAL; RESPIRATORY FUNCTION TESTS

Mesh:

Substances:

Year:  1964        PMID: 14156570     DOI: 10.1097/00000542-196405000-00007

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


× No keyword cloud information.
  28 in total

1.  A method for overcoming the ceiling effect of bounded pain scales.

Authors:  M W Hartmannsgruber; C P Swamidoss; A Budde; S Qadir; S J Brull; D G Silverman
Journal:  J Clin Monit Comput       Date:  1999-12       Impact factor: 2.502

2.  On the use of isofluorane as an anaesthetic for visual neurophysiology.

Authors:  D A Tigwell; J Sauter
Journal:  Exp Brain Res       Date:  1992       Impact factor: 1.972

3.  The effect of addition of nitrous oxide to a sevoflurane anesthetic on BIS, PSI, and entropy.

Authors:  Roy G Soto; Robert A Smith; Amy L Zaccaria; Rafael V Miguel
Journal:  J Clin Monit Comput       Date:  2006-06-21       Impact factor: 2.502

4.  Meperidine-halothane interaction in dogs.

Authors:  E P Steffey; R Martucci; D Howland; J H Asling; J H Eisele
Journal:  Can Anaesth Soc J       Date:  1977-07

Review 5.  [Pharmacokinetic-pharmacodynamic models for inhaled anaesthetics].

Authors:  S Kreuer; J Bruhn; W Wilhelm; T Bouillon
Journal:  Anaesthesist       Date:  2007-06       Impact factor: 1.041

Review 6.  General anesthesia.

Authors:  M Rosenberg; J Weaver
Journal:  Anesth Prog       Date:  1991 Jul-Oct

7.  Epidural administered buprenorphine in the perioperative period.

Authors:  Y Miwa; E Yonemura; K Fukushima
Journal:  Can J Anaesth       Date:  1996-09       Impact factor: 5.063

Review 8.  Safety considerations in the use of drug combinations during general anaesthesia.

Authors:  E S Ransom; R A Mueller
Journal:  Drug Saf       Date:  1997-02       Impact factor: 5.606

9.  Accuracy and cross-sensitivity of 10 different anesthetic gas monitors.

Authors:  B Walder; R Lauber; A M Zbinden
Journal:  J Clin Monit       Date:  1993-11

10.  A mechanical stimulator for the determination of the minimum alveolar concentration (MAC) of halothane in the rabbit.

Authors:  A T Sobair; D F Cottrell; M A Camburn
Journal:  Vet Res Commun       Date:  1993       Impact factor: 2.459

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.