Literature DB >> 10220980

Biomechanical analysis of arch-guided molar distalization when employing superelastic NiTi coil springs.

R Schneevoigt1, C Bourauel, W Harzer, L Eckardt.   

Abstract

Two typical treatment situations (distalization of a last molar, distalization of a molar with the guiding arch fixed on the most distal abutment tooth) were simulated experimentally using the Orthodontic Measurement and Simulation System (OMSS). For this purpose an upper first molar was guided along steel arches with differing cross sections (0.016" x 0.022"/0.41 mm x 0.56 mm; 0.017" x 0.025"/0.43 mm x 0.64 mm) using a nickel-titanium (NiTi) compression spring. The 6 NiTi springs investigated differed in their design and in the type of force delivery. The force application that was eccentric with respect to the center of resistance caused a conflict situation between the tube and the guiding arch through rotations of the molar. Although the force level of the springs was almost constant, the orthodontically effective forces measured fluctuated due to frictional losses. With progressing distalization the mean frictional forces increased, reaching values between 50 and 80% of the applied force of the compression springs. Simultaneously fluctuations in the frictional losses increased. Lower frictional losses were determined with a 0.016" x 0.022", than with a 0.017" x 0.025" guiding arch. Fixing the arch on the 3rd molar resulted in higher frictional losses compared to the distalization of a last molar. There were intensive interactions of the compression springs with the guiding arch and the tube. This resulted in extreme frictional losses even in the initial phase of the movement and in a complete stop to the distalizing movement in extreme cases. After removal of the convertible, the freedom of the molar movement could be regulated by the tension of the ligature wire. The friction varied accordingly. The distalization rate was not influenced by the force delivered by the compression spring. Small forces are biologically more favorable and thus should be preferred.

Mesh:

Substances:

Year:  1999        PMID: 10220980     DOI: 10.1007/bf01298962

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  22 in total

1.  [The effect of physiological tooth mobility on the friction between the bracket and the arch].

Authors:  P Jost-Brinkmann; R R Miethke
Journal:  Fortschr Kieferorthop       Date:  1991-04

2.  Frictional forces between bracket and arch wire.

Authors:  D Drescher; C Bourauel; H A Schumacher
Journal:  Am J Orthod Dentofacial Orthop       Date:  1989-11       Impact factor: 2.650

3.  The effect of temperature change on the load value of Japanese NiTi coil springs in the superelastic range.

Authors:  O Barwart
Journal:  Am J Orthod Dentofacial Orthop       Date:  1996-11       Impact factor: 2.650

4.  [The effect of the ligature on the friction between bracket and arch].

Authors:  H A Schumacher; C Bourauel; D Drescher
Journal:  Fortschr Kieferorthop       Date:  1990-04

5.  The use of magnets to move molars distally.

Authors:  A A Gianelly; A S Vaitas; W M Thomas
Journal:  Am J Orthod Dentofacial Orthop       Date:  1989-08       Impact factor: 2.650

6.  [Materials technology research on the problem of friction between bracket and arch].

Authors:  D Drescher; W Laaser; H A Schumacher
Journal:  Fortschr Kieferorthop       Date:  1989-08

7.  A comparison of frictional forces during simulated canine retraction of a continuous edgewise arch wire.

Authors:  L D Garner; W W Allai; B K Moore
Journal:  Am J Orthod Dentofacial Orthop       Date:  1986-09       Impact factor: 2.650

8.  A reassessment of force magnitude in orthodontics.

Authors:  R S Quinn; D K Yoshikawa
Journal:  Am J Orthod       Date:  1985-09

9.  A comparison of friction resistance for Nitinol and stainless steel wire in edgewise brackets.

Authors:  L Peterson; R Spencer; G Andreasen
Journal:  Quintessence Int Dent Dig       Date:  1982-05

10.  A comparative study of frictional resistances between orthodontic bracket and arch wire.

Authors:  C A Frank; R J Nikolai
Journal:  Am J Orthod       Date:  1980-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.