Migration of porous coated acetabular prostheses fixed with screws: roentgen stereophotogrammetric analysis.

J Kärrholm1, F Snorrason.   

Abstract

The fixation of screw-fixed, porous-coated acetabular prostheses was studied during 2 years in 21 patients (22 hips) using repeated roentgen stereophotogrammetric measurements. Migration of the center of the prostheses and/or tilting were recorded in five cups after 6 months. Two years after operation, migration was recorded in three, migration and rotation in six, and only rotation in three cups. Bone quality, prosthetic position, and immediate postoperative radiographic appearance of the prosthesis-bone interface did not correlate with the occurrence of migration. Narrow radiolucent zones had developed in half of the patients after 2 years and was associated with proximal migration. Micromovements of screw-fixed, press-fit cups seem to start later compared with previously presented results from cemented acetabular prosthesis.

Entities:  

Mesh:

Year:  1992        PMID: 1403297     DOI: 10.1002/jor.1100100612

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  4 in total

1.  Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.

Authors:  David C Ayers; Meridith Greene; Benjamin Snyder; Michelle Aubin; Jacob Drew; Charles Bragdon
Journal:  J Bone Joint Surg Am       Date:  2015-04-15       Impact factor: 5.284

2.  Effects of screw eccentricity on the initial stability of the acetabular cup.

Authors:  Jui-Ting Hsu; Chih-Han Chang; Kai-Nan An; Mark E Zobitz; Rapin Phimolsarnti; Ronald R Hugate; Kuo-An Lai
Journal:  Int Orthop       Date:  2006-09-01       Impact factor: 3.075

3.  Acetabular reconstruction in developmental hip dysplasia using reinforcement ring with a hook.

Authors:  Rocco P Pitto; Nils Schikora
Journal:  Int Orthop       Date:  2004-04-30       Impact factor: 3.075

4.  Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty: a randomized RSA and bone mineral densitometry study of 50 hips.

Authors:  Thomas Baad-Hansen; Søren Kold; Poul Torben Nielsen; Mogens Berg Laursen; Poul Hedevang Christensen; Kjeld Soballe
Journal:  Acta Orthop       Date:  2011-03-25       Impact factor: 3.717

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.