A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone.

L Sennerby1, P Thomsen, L E Ericson.   

Abstract

The removal torques for screw-shaped pure titanium implants inserted in rabbit tibia and the femoral part of the knee joint and the tissue response to these implants, as quantitated with light microscopic morphometry on ground sections, were compared after 6 weeks, 3 months, and 6 months. The bone surrounding the femoral intra-articular implants was mostly cancellous, while cortical bone was formed around the tibial implants. The torque needed to remove the intra-articular implants increased with time, but there was no such increase for the tibial implants. At 6 weeks, significantly less torque was needed to remove the intra-articular implants in spite of the fact that significantly more bone was found in the threads of these implants as compared with the tibial implants. When calculating the amount of bone in threads situated in the cortical and subchondral passage, more was found in the threads of the tibial implants, which corresponded to the higher removal torque. Additional light microscopic observations on implants unscrewed after 12 months in rabbit tibia indicated that rupture occurred between the implant surface and calcified bone. Findings indicate that the resistance to unscrewing is dependent on the amount of compact bone surrounding a titanium implant.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1398826

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  24 in total

1.  [Primary implant stability with different bone surgery techniques. An in vitro study of the mandible of the minipig].

Authors:  A Büchter; J Kleinheinz; U Joos; U Meyer
Journal:  Mund Kiefer Gesichtschir       Date:  2003-10-24

2.  Studies of the healing of bone grafts, and the incorporation of titanium implants in grafted bone: an experimental animal model.

Authors:  E Liljensten; C Larsson; P Thomsen; G Blomqvist; J M Hirsch; C Wedenberg
Journal:  J Mater Sci Mater Med       Date:  1998-09       Impact factor: 3.896

3.  Structure of the interface between rabbit cortical bone and implants of gold, zirconium and titanium.

Authors:  P Thomsen; C Larsson; L E Ericson; L Sennerby; J Lausmaa; B Kasemo
Journal:  J Mater Sci Mater Med       Date:  1997-11       Impact factor: 3.896

4.  The effect of implant shape and bone preparation on primary stability.

Authors:  Sang-Hyun Moon; Heung-Sik Um; Jae-Kwan Lee; Beom-Seok Chang; Min-Ku Lee
Journal:  J Periodontal Implant Sci       Date:  2010-10-31       Impact factor: 2.614

5.  Osseointegration of titanium implants with SLAffinity treatment: a histological and biomechanical study in miniature pigs.

Authors:  Keng-Liang Ou; Heng-Jui Hsu; Tzu-Sen Yang; Yun-Ho Lin; Chin-Sung Chen; Pei-Wen Peng
Journal:  Clin Oral Investig       Date:  2015-10-28       Impact factor: 3.573

6.  Assessment of Osstell™ and Periotest® systems in measuring dental implant stability (in vitro study).

Authors:  Samer Al-Jetaily; Abdullah Alfarraj Al-Dosari
Journal:  Saudi Dent J       Date:  2010-11-13

7.  The use of light/chemically hardened polymethylmethacrylate, polyhydroxylethylmethacrylate, and calcium hydroxide graft material in combination with polyanhydride around implants and extraction sockets in minipigs: Part II: histologic and micro-CT evaluations.

Authors:  Hatice Hasturk; Alpdogan Kantarci; Mazen Ghattas; Smit J Dangaria; Rima Abdallah; Elise F Morgan; Thomas G H Diekwisch; Arthur Ashman; Thomas Van Dyke
Journal:  J Periodontol       Date:  2014-02-06       Impact factor: 6.993

8.  The use of light/chemically hardened polymethylmethacrylate, polyhydroxyethylmethacrylate, and calcium hydroxide graft material in combination with polyanhydride around implants in minipigs: part I: immediate stability and function.

Authors:  Hatice Hasturk; Alpdogan Kantarci; Mazen Ghattas; Marcella Schmidt; Russell A Giordano; Arthur Ashman; Thomas G Diekwisch; Thomas Van Dyke
Journal:  J Periodontol       Date:  2011-02-22       Impact factor: 6.993

9.  Biomechanical evaluation of dental implants with different surfaces: Removal torque and resonance frequency analysis in rabbits.

Authors:  Jung-Woo Koh; Jae-Ho Yang; Jung-Suk Han; Jai-Bong Lee; Sung-Hun Kim
Journal:  J Adv Prosthodont       Date:  2009-07-31       Impact factor: 1.904

10.  Bone response to surface modified titanium implants - studies on the tissue response after 1 year to machined and electropolished implants with different oxide thicknesses.

Authors:  C Larsson; L Emanuelsson; P Thomsen; L E Ericson; B O Aronsson; B Kasemo; J Lausmaa
Journal:  J Mater Sci Mater Med       Date:  1997-12       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.