Literature DB >> 15348780

Bone response to surface modified titanium implants - studies on the tissue response after 1 year to machined and electropolished implants with different oxide thicknesses.

C Larsson1, L Emanuelsson, P Thomsen, L E Ericson, B O Aronsson, B Kasemo, J Lausmaa.   

Abstract

The bone formation around titanium implants with varied surface properties was investigated after 1 year in rabbits. Machined and electropolished samples with and without thick, anodically formed surface oxides were prepared, surface characterized and inserted in the cortical bone of rabbits. Scanning electron microscopy, scanning Auger electron spectroscopy and atomic force microscopy revealed marked differences in oxide thickness, surface topography and roughness, but no significant differences in surface chemical composition between the different groups of implants. Light microscopic morphology and morphometry showed that all implants were in contact with bone and had a large proportion of bone within the threads. There were no significant differences between the differently prepared implant groups. Our study shows that a high degree of bone contact and bone formation is achieved after 1 year with titanium implants which are modified with respect to oxide thickness and surface topography. There is no indication that a reduction of surface roughness, which in the initial phase decreases the rate of bone formation, had any influence on the amount of bone after 1 year in rabbit cortical bone.

Entities:  

Year:  1997        PMID: 15348780     DOI: 10.1023/a:1018548225899

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  29 in total

1.  Characterization of sterilized CP titanium implant surfaces.

Authors:  J C Keller; R A Draughn; J P Wightman; W J Dougherty; S D Meletiou
Journal:  Int J Oral Maxillofac Implants       Date:  1990       Impact factor: 2.804

2.  Structure of the bone-titanium interface in retrieved clinical oral implants.

Authors:  L Sennerby; L E Ericson; P Thomsen; U Lekholm; P Astrand
Journal:  Clin Oral Implants Res       Date:  1991 Jul-Sep       Impact factor: 5.977

3.  Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs.

Authors:  D Buser; R K Schenk; S Steinemann; J P Fiorellini; C H Fox; H Stich
Journal:  J Biomed Mater Res       Date:  1991-07

4.  Intra-osseous anchorage of dental prostheses. I. Experimental studies.

Authors:  P I Brånemark; R Adell; U Breine; B O Hansson; J Lindström; A Ohlsson
Journal:  Scand J Plast Reconstr Surg       Date:  1969

5.  Design and surface characteristics of 13 commercially available oral implant systems.

Authors:  A Wennerberg; T Albrektsson; B Andersson
Journal:  Int J Oral Maxillofac Implants       Date:  1993       Impact factor: 2.804

6.  The effect of calcium phosphate ceramic composition and structure on in vitro behavior. I. Dissolution.

Authors:  P Ducheyne; S Radin; L King
Journal:  J Biomed Mater Res       Date:  1993-01

7.  Bone growth to metal implants is regulated by their surface chemical properties.

Authors:  R Hazan; R Brener; U Oron
Journal:  Biomaterials       Date:  1993-07       Impact factor: 12.479

8.  Interaction of fibroblasts and polymer surfaces: relationship between surface free energy and fibroblast spreading.

Authors:  P van der Valk; A W van Pelt; H J Busscher; H P de Jong; C R Wildevuur; J Arends
Journal:  J Biomed Mater Res       Date:  1983-09

9.  Inhibition of apatite formation by titanium and vanadium ions.

Authors:  N C Blumenthal; V Cosma
Journal:  J Biomed Mater Res       Date:  1989-04

10.  Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man.

Authors:  T Albrektsson; P I Brånemark; H A Hansson; J Lindström
Journal:  Acta Orthop Scand       Date:  1981
View more
  11 in total

1.  In vitro bioactivity of sol-gel-derived hydroxyapatite particulate nanofiber modified titanium.

Authors:  Madhab Prasad Bajgai; Daman Chandra Parajuli; Soo-Jin Park; Kong Hee Chu; Hyung-Sub Kang; Hak Yong Kim
Journal:  J Mater Sci Mater Med       Date:  2009-10-23       Impact factor: 3.896

2.  The cell attachment and morphology of neonatal rat calvarial osteoblasts on the surface of Ti-6Al-4V and plasma-sprayed HA coating: effect of surface roughness and serum contents.

Authors:  T M Lee; R S Tsai; E Chang; C Y Yang; M R Yang
Journal:  J Mater Sci Mater Med       Date:  2002-04       Impact factor: 3.896

3.  Effect of surface anodization on stability of orthodontic microimplant.

Authors:  Sanket Karmarker; Wonjae Yu; Hee-Moon Kyung
Journal:  Korean J Orthod       Date:  2012-02-27       Impact factor: 1.372

Review 4.  Dental implant systems.

Authors:  Yoshiki Oshida; Elif B Tuna; Oya Aktören; Koray Gençay
Journal:  Int J Mol Sci       Date:  2010-04-12       Impact factor: 5.923

5.  MC3T3-E1 Cells on Titanium Surfaces with Nanometer Smoothness and Fibronectin Immobilization.

Authors:  Tohru Hayakawa; Eiji Yoshida; Yoshitaka Yoshimura; Motohiro Uo; Masao Yoshinari
Journal:  Int J Biomater       Date:  2012-05-22

6.  A histomorphometric study of dental implants with different surface characteristics.

Authors:  Hyun-Soon Pak; In-Sung Yeo; Jae-Ho Yang
Journal:  J Adv Prosthodont       Date:  2010-12-31       Impact factor: 1.904

7.  Biomaterials in cochlear implants.

Authors:  Timo Stöver; Thomas Lenarz
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2011-03-10

8.  Bone response to surface-modified titanium implants: studies on the early tissue response to implants with different surface characteristics.

Authors:  C Larsson Wexell; P Thomsen; B-O Aronsson; P Tengvall; M Rodahl; J Lausmaa; B Kasemo; L E Ericson
Journal:  Int J Biomater       Date:  2013-09-23

9.  Comparison of implant stability after different implant surface treatments in dog bone.

Authors:  Sun-Jong Kim; Myung-Rae Kim; Jae-Suk Rim; Sung-Min Chung; Sang-Wan Shin
Journal:  J Appl Oral Sci       Date:  2010 Jul-Aug       Impact factor: 2.698

10.  Influence of nicotine on machined- and anodized-surface implants. Histometric analysis.

Authors:  Maria-Salete-Sandini Linden; Luiz-Renato Paranhos; João-Paulo De Carli; Micheline-Sandini Trentin; Marcos-Eugênio de Bittencourt; Pâmela-Letícia Santos; Francisco-Carlos Groppo; Juliana-Camma Ramacciato
Journal:  J Clin Exp Dent       Date:  2017-10-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.