Literature DB >> 1392252

Minimizing TE in moment-nulled or flow-encoded two- and three-dimensional gradient-echo imaging.

M A Bernstein1, A Shimakawa, N J Pelc.   

Abstract

A method for minimizing field-echo delay in moment-nulled gradient-echo imaging is presented. Even though ramps are accounted for, the analysis yields simple closed-form solutions. The method is then generalized to the section-select waveform for three-dimensional volume imaging and to flow encoding for phase-contrast imaging. Three strategies for first-moment selection in phase-contrast imaging are discussed, including a new strategy that always yields the minimum echo delay. Trapezoidal and triangular gradient lobe shapes are analyzed.

Entities:  

Mesh:

Year:  1992        PMID: 1392252     DOI: 10.1002/jmri.1880020517

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  27 in total

Review 1.  Four-dimensional flow magnetic resonance imaging in cirrhosis.

Authors:  Zoran Stankovic
Journal:  World J Gastroenterol       Date:  2016-01-07       Impact factor: 5.742

2.  Real-time blood flow imaging using autocalibrated spiral sensitivity encoding.

Authors:  Reza Nezafat; Peter Kellman; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

3.  Flow-compensated self-gating.

Authors:  Jessica Schulz; Matthias Korn; Michael Deimling; Wolfhard Semmler; Michael Bock
Journal:  MAGMA       Date:  2008-07-31       Impact factor: 2.310

4.  Efficient triple-VENC phase-contrast MRI for improved velocity dynamic range.

Authors:  Liliana E Ma; Michael Markl; Kelvin Chow; Alireza Vali; Can Wu; Susanne Schnell
Journal:  Magn Reson Med       Date:  2019-08-18       Impact factor: 4.668

5.  Accelerated dual-venc 4D flow MRI for neurovascular applications.

Authors:  Susanne Schnell; Sameer A Ansari; Can Wu; Julio Garcia; Ian G Murphy; Ozair A Rahman; Amir A Rahsepar; Maria Aristova; Jeremy D Collins; James C Carr; Michael Markl
Journal:  J Magn Reson Imaging       Date:  2017-02-02       Impact factor: 4.813

6.  k-t BLAST and SENSE accelerated time-resolved three-dimensional phase contrast MRI in an intracranial aneurysm.

Authors:  Pim van Ooij; Annetje Guédon; Henk A Marquering; Joppe J Schneiders; Charles B Majoie; Ed van Bavel; Aart J Nederveen
Journal:  MAGMA       Date:  2012-09-07       Impact factor: 2.310

7.  Volumetric velocity measurements in restricted geometries using spiral sampling: a phantom study.

Authors:  Anders Nilsson; Johan Revstedt; Einar Heiberg; Freddy Ståhlberg; Karin Markenroth Bloch
Journal:  MAGMA       Date:  2014-05-18       Impact factor: 2.310

8.  Optimization methods for magnetic resonance imaging gradient waveform design.

Authors:  Matthew J Middione; Michael Loecher; Kévin Moulin; Daniel B Ennis
Journal:  NMR Biomed       Date:  2020-04-27       Impact factor: 4.044

9.  4D spiral imaging of flows in stenotic phantoms and subjects with aortic stenosis.

Authors:  M J Negahdar; Mo Kadbi; Michael Kendrick; Marcus F Stoddard; Amir A Amini
Journal:  Magn Reson Med       Date:  2015-04-27       Impact factor: 4.668

10.  Improved SNR in phase contrast velocimetry with five-point balanced flow encoding.

Authors:  Kevin M Johnson; Michael Markl
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.