Effect of fetal haemoglobin on the accuracy of pulse oximetry in preterm infants.

V S Rajadurai1, A M Walker, V Y Yu, A Oates.   

Abstract

Pulse oximeters are programmed with a calibration curve derived from studies done in adults. Whether fetal haemoglobin levels affect their reliability is unclear. This study reports the accuracy of pulse oximetry in 22 preterm infants (mean 31 weeks, range 25-36 weeks gestation) between 1 h and 73 days of age. Oxygen saturation obtained from a Nellcor N-200 pulse oximeter (SpO2) was compared with simultaneous arterial values (functional SaO2) measured by a Radiometer OSM3 Hemoximeter over a SpO2 range of 83-99%. Fetal haemoglobin (HbF), carboxyhaemoglobin (HbCO) and methaemoglobin (HbMet) measured by the hemoximeter ranged between 0-100%, 0-3.5% and 0-0.8% respectively. Linear regression analysis revealed a close correlation between SpO2 and functional SaO2 (SpO2 = 0.75 SaO2 + 24.43, r = 0.88, P less than 0.001) over a wide range of values for PCV, heart rate, blood pressure, PaO2, PaCO2 and pH. The mean SpO2-SaO2 difference of 1.3, (s.d. 2.5%, P less than 0.001) was unaffected by HgF, HbCO or HbMet but was increased in infants receiving inotropic support. We conclude that the Nellcor N-200 pulse oximeter gives reliable oxygen saturation measurements unaffected by the HbF level in preterm infants.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1372809     DOI: 10.1111/j.1440-1754.1992.tb02615.x

Source DB:  PubMed          Journal:  J Paediatr Child Health        ISSN: 1034-4810            Impact factor:   1.954


  7 in total

Review 1.  Factors influencing fetal pulse oximetry performance.

Authors:  James L Reuss
Journal:  J Clin Monit Comput       Date:  2004-02       Impact factor: 2.502

2.  The measurement of accurate fetal hemoglobin and related oxygen saturation by the hemoximeter.

Authors:  Shyang-Yun Pamela K Shiao; Ching-Nan Ou; Hector Pierantoni
Journal:  Clin Chim Acta       Date:  2006-06-06       Impact factor: 3.786

3.  Validation of oxygen saturation monitoring in neonates.

Authors:  Shyang-Yun Pamela K Shiao; Ching-Nan Ou
Journal:  Am J Crit Care       Date:  2007-03       Impact factor: 2.228

4.  Camera-based pulse-oximetry - validated risks and opportunities from theoretical analysis.

Authors:  Mark Van Gastel; Sander Stuijk; Gerard De Haan
Journal:  Biomed Opt Express       Date:  2017-12-05       Impact factor: 3.732

Review 5.  Hemoglobin oxygen saturation targets in the neonatal intensive care unit: Is there a light at the end of the tunnel? 1.

Authors:  Payam Vali; Mark Underwood; Satyan Lakshminrusimha
Journal:  Can J Physiol Pharmacol       Date:  2018-10-26       Impact factor: 2.273

Review 6.  Accuracy of Pulse Oximetry in the Presence of Fetal Hemoglobin-A Systematic Review.

Authors:  Ena Pritišanac; Berndt Urlesberger; Bernhard Schwaberger; Gerhard Pichler
Journal:  Children (Basel)       Date:  2021-04-30

Review 7.  Oxygen targeting in preterm infants: a physiological interpretation.

Authors:  S Lakshminrusimha; V Manja; B Mathew; G K Suresh
Journal:  J Perinatol       Date:  2014-10-30       Impact factor: 2.521

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.