BACKGROUND: The effect of left ventricular (LV) systolic function on the long-term left ventricular pacing and sensing threshold is unclear. METHODS AND RESULTS: We studied the effect of LV ejection fraction (LVEF) on the LV pacing and sensing threshold in 56 patients (mean age: 70.2 +/- 10.5 years) underwent permanent LV pacing using a self-retaining coronary sinus lead (Model 1055 K, St Jude Medical, USA). In 49 patients, the LV lead was implanted for conventional pacemaker indication (sick sinus syndrome = 14, heart block = 26 or slow atrial fibrillation = 9). The remaining 7 patients were implanted for congestive heart failure. The LV pacing and sensing threshold, and lead impedance were compared between patients with LVEF <40% (Group 1, n = 28) and LVEF >40% (Group 2, n = 28) during implant and at 3-month follow up. The LV pacing lead was successfully implanted in all patients without any lead dislodgement on follow-up. At implant, Group 1 patients had a significant lower R wave amplitude, but similar LV pacing threshold and lead impedance as compared to Group 2. However, at 3-month follow-up, Group 1 patients had a significantly higher LV pacing threshold compared to Group 2 patients. There were no significant differences in the sensing threshold and lead impedance between the two groups. Furthermore, there was also a significant interval increase in LV pacing threshold in Group 1 patients (0.94 +/- 0.12 V) after 3 months, but not in Group 2 patients (0.16 +/- 0.08 V, p < 0.01). CONCLUSIONS: The results of this study suggest that the LV systolic function has a significant impact on the long-term LV pacing threshold. The long-term left ventricular pacing threshold in patients with left ventricular systolic dysfunction increased after implant and was higher than patients with normal left ventricular systolic function.
BACKGROUND: The effect of left ventricular (LV) systolic function on the long-term left ventricular pacing and sensing threshold is unclear. METHODS AND RESULTS: We studied the effect of LV ejection fraction (LVEF) on the LV pacing and sensing threshold in 56 patients (mean age: 70.2 +/- 10.5 years) underwent permanent LV pacing using a self-retaining coronary sinus lead (Model 1055 K, St Jude Medical, USA). In 49 patients, the LV lead was implanted for conventional pacemaker indication (sick sinus syndrome = 14, heart block = 26 or slow atrial fibrillation = 9). The remaining 7 patients were implanted for congestive heart failure. The LV pacing and sensing threshold, and lead impedance were compared between patients with LVEF <40% (Group 1, n = 28) and LVEF >40% (Group 2, n = 28) during implant and at 3-month follow up. The LV pacing lead was successfully implanted in all patients without any lead dislodgement on follow-up. At implant, Group 1 patients had a significant lower R wave amplitude, but similar LV pacing threshold and lead impedance as compared to Group 2. However, at 3-month follow-up, Group 1 patients had a significantly higher LV pacing threshold compared to Group 2 patients. There were no significant differences in the sensing threshold and lead impedance between the two groups. Furthermore, there was also a significant interval increase in LV pacing threshold in Group 1 patients (0.94 +/- 0.12 V) after 3 months, but not in Group 2 patients (0.16 +/- 0.08 V, p < 0.01). CONCLUSIONS: The results of this study suggest that the LV systolic function has a significant impact on the long-term LV pacing threshold. The long-term left ventricular pacing threshold in patients with left ventricular systolic dysfunction increased after implant and was higher than patients with normal left ventricular systolic function.
Authors: William T Abraham; Westby G Fisher; Andrew L Smith; David B Delurgio; Angel R Leon; Evan Loh; Dusan Z Kocovic; Milton Packer; Alfredo L Clavell; David L Hayes; Myrvin Ellestad; Robin J Trupp; Jackie Underwood; Faith Pickering; Cindy Truex; Peggy McAtee; John Messenger Journal: N Engl J Med Date: 2002-06-13 Impact factor: 91.245
Authors: J C Daubert; P Ritter; H Le Breton; D Gras; C Leclercq; A Lazarus; J Mugica; P Mabo; S Cazeau Journal: Pacing Clin Electrophysiol Date: 1998-01 Impact factor: 1.976
Authors: Jan Steffel; Anja Hurlimann; Christoph Starck; Nazmi Krasniqi; Susann Schmidt; Thomas F Luscher; Firat Duru; Frank Ruschitzka; Johannes Holzmeister; David Hurlimann Journal: Indian Pacing Electrophysiol J Date: 2014-05-25