Literature DB >> 12974861

Assessing microleakage of different class V restorations after Er:YAG laser and bur preparation.

S A M Corona1, M C Borsatto, J D Pecora, R A S De SA Rocha, T S Ramos, R G Palma-Dibb.   

Abstract

This study assessed in vitro marginal leakage of class V cavities prepared by turbine and Er:YAG laser and restored with different materials. Sixty cavities with enamel and dentine margins were prepared and assigned to six groups: I, II, III by turbine and IV, V, VI by Er:YAG laser. The following restorative systems were used: groups I and IV: Bond 1 + Alert; II and V: Fuji II LC; III and VI: SBMP + Dispersalloy. After finishing, specimens were thermocycled for 8 h and 45 min (500 cycles), isolated, immersed in a 0.2% Rhodamine B solution, sectioned oro-facially and analysed for leakage. The dye penetration means (%) were: occlusal I: 10.09 (+/- 21.28), II: 3.25 (+/- 10.27), III: 0, IV: 41.77 (+/- 42.48), V: 23.37 (+/- 33.79), VI: 12.66 (+/- 24.06); cervical I: 16.49 (+/- 26.67), II: 4.34 (+/- 13.71), III: 0, IV: 37.71 (+/- 30.47), V: 39.56 (+/- 43.35) and VI: 72.53 (+/- 37.79). The use of Er:YAG laser for cavity preparation yielded higher degree of marginal leakage, as compared with the use of conventional air-turbine. The enamel interface provided better marginal sealing, comparing with dentine/cementum margin. As to the cavity preparation device (i.e. laser or bur), the analysis of the results showed that bonded amalgam and Fuji II LC provided less infiltration, than Alert. On the other hand, for lased cavities, Alert provided the best results, similar to those of Fuji II LC and superior to those reached by bonded amalgam.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12974861     DOI: 10.1046/j.1365-2842.2003.01173.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  18 in total

1.  Microleakage in class V gingiva-shaded composite resin restorations.

Authors:  Claudio Poggio; Marco Chiesa; Alberto Dagna; Marco Colombo; Andrea Scribante
Journal:  Ann Stomatol (Roma)       Date:  2012-05-03

2.  Comparison of the Er,Cr:YSGG laser with a chemical vapour deposition bur and conventional techniques for cavity preparation: a microleakage study.

Authors:  A Rüya Yazici; Zeren Yıldırım; Sibel A Antonson; Evren Kilinc; Daniele Koch; Donald E Antonson; Berrin Dayangaç; Gül Ozgünaltay
Journal:  Lasers Med Sci       Date:  2010-09-15       Impact factor: 3.161

3.  Effect of different power parameters of Er,Cr:YSGG laser on human dentine.

Authors:  Piyanart Ekworapoj; Sharanbir K Sidhu; John F McCabe
Journal:  Lasers Med Sci       Date:  2007-01-23       Impact factor: 3.161

4.  Er,Cr:YSGG laser influence on microleakage of class V composite resin restorations.

Authors:  Tahereh Fattah; Haleh Kazemi; Reza Fekrazad; Hadi Assadian; Katayoun A M Kalhori
Journal:  Lasers Med Sci       Date:  2012-09-26       Impact factor: 3.161

5.  Comparison of Micro-Leakage from Resin-Modified Glass Ionomer Restorations in Cavities Prepared by Er:YAG (Erbium-Doped Yttrium Aluminum Garnet) Laser and Conventional Method in Primary Teeth.

Authors:  Zahra Bahrololoomi; Forooghosadat Razavi; Ali Asghar Soleymani
Journal:  J Lasers Med Sci       Date:  2014

6.  Microleakage of Er:YAG laser and dental bur prepared cavities in primary teeth restored with different adhesive restorative materials.

Authors:  Ali Baghalian; Yahya B Nakhjavani; Tabassom Hooshmand; Pouria Motahhary; Hoda Bahramian
Journal:  Lasers Med Sci       Date:  2012-11-08       Impact factor: 3.161

7.  Effect of the erbium:yttrium-aluminum-garnet laser or diamond bur cavity preparation on the marginal microleakage of class V cavities restored with different adhesives and composite systems.

Authors:  Batu Can Yaman; Begum Efes Guray; Can Dorter; Yavuz Gomeç; Oktay Yazıcıoglu; Dina Erdilek
Journal:  Lasers Med Sci       Date:  2011-08-16       Impact factor: 3.161

8.  Microleakage and scanning electron microscopy evaluation of all-in-one self-etch adhesives and their respective nanocomposites prepared by erbium:yttrium-aluminum-garnet laser and bur.

Authors:  Yonca Korkmaz; Emre Ozel; Nuray Attar; Ceren Ozge Bicer; Erhan Firatli
Journal:  Lasers Med Sci       Date:  2009-04-27       Impact factor: 3.161

9.  Microleakage of glass ionomer formulations after erbium:yttrium-aluminium-garnet laser preparation.

Authors:  Katleen I M Delmé; Peter J Deman; Mieke A A De Bruyne; Samir Nammour; Roeland J G De Moor
Journal:  Lasers Med Sci       Date:  2008-08-21       Impact factor: 3.161

10.  The influence of erbium:yttrium-aluminum-garnet laser ablation with variable pulse width on morphology and microleakage of composite restorations.

Authors:  Ricardo Scarparo Navarro; Sheila Gouw-Soares; Alessandra Cassoni; Patricia Haypek; Denise Maria Zezell; Carlos de Paula Eduardo
Journal:  Lasers Med Sci       Date:  2009-10-04       Impact factor: 3.161

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.