Literature DB >> 12940563

Effects of ligation type and method on the resistance to sliding of novel orthodontic brackets with second-order angulation in the dry and wet states.

Glenys A Thorstenson1, Robert P Kusy.   

Abstract

Rectangular stainless steel (SS) archwires were coupled with four SS bracket designs: Mini Diamond Twin, which was a conventional twin bracket; VersaT, which had bumps along the slot floor and rounded slot walls; Shoulder, which had bosses outside the tie-wings to lift the ligation off the archwire; and Synergy, which had bosses between the outer and inner tie-wings, bumps along the slot floor, and rounded slot walls. For all designs, the values of resistance to sliding (RS) were measured at five normal forces and 32 second-order angulations in the dry and wet (saliva) states. RS values at these same angles and states were also measured for the following: Mini Diamond Twin brackets ligated with rings and SS ligature wires; VersaT brackets ligated with rings; Shoulder brackets ligated with rings in a figure-8 and a figure-O around the tie-wings; and Synergy brackets ligated with rings around the outer tie-wings and around the inner tie-wings. In both states, the coefficients of friction were similar for the Mini Diamond Twin, VersaT, and Synergy brackets; the values for the Shoulder brackets were slightly greater than for the other three designs. In the passive configuration, the features of the Shoulder and Synergy brackets reduced RS when the rings were not in contact with the archwires. In the active configuration, the binding behavioral patterns of the brackets were not influenced by ligation methods. Thus, these different ligation types and methods only affected the classical frictional component of RS in the passive configuration.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12940563     DOI: 10.1043/0003-3219(2003)073<0418:EOLTAM>2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  15 in total

1.  The dynforce archwire.

Authors:  Daniele Cantarella; Luca Lombardo; Giuseppe Siciliani
Journal:  Ann Stomatol (Roma)       Date:  2013-06-25

2.  Evaluation of friction in orthodontics using various brackets and archwire combinations-an in vitro study.

Authors:  Sujeet Kumar; Shamsher Singh; Rani Hamsa P R; Sameer Ahmed; Apoorva Bhatnagar; Manreet Sidhu; Pramod Shetty
Journal:  J Clin Diagn Res       Date:  2014-05-15

3.  Friction and archwire engagement in contemporary self-ligating appliance systems : An in vitro comparison.

Authors:  Michael Greene; Amin Rizkalla; Timothy Burkhart; Antonios Mamandras; Ali Tassi
Journal:  J Orofac Orthop       Date:  2021-11-15       Impact factor: 1.938

4.  A comparative anchorage control study between conventional and self-ligating bracket systems using differential moments.

Authors:  Marcio Rodrigues de Almeida; Francisco Herrero; Amine Fattal; Amirparviz R Davoody; Ravindra Nanda; Flavio Uribe
Journal:  Angle Orthod       Date:  2013-06-07       Impact factor: 2.079

5.  In vitro assessment of competency for different lingual brackets in sliding mechanics.

Authors:  S Lalithapriya; N Kurunji Kumaran; K Rajasigamani
Journal:  J Orthod Sci       Date:  2015 Jan-Mar

6.  Comparison of Frictional Forces Generated by a New Ceramic Bracket with the Conventional Brackets using Unconventional and Conventional Ligation System and the Self-ligating Brackets: An In Vitro Study.

Authors:  Azam Pasha; Swati Vishwakarma; Anjali Narayan; K Vinay; Smitha V Shetty; Partha Pratim Roy
Journal:  J Int Oral Health       Date:  2015-09

7.  Does the bracket-ligature combination affect the amount of orthodontic space closure over three months? A randomized controlled trial.

Authors:  Henry Wong; Jill Collins; David Tinsley; Jonathan Sandler; Philip Benson
Journal:  J Orthod       Date:  2013-06

8.  Friction between different wire bracket combinations in artificial saliva--an in vitro evaluation.

Authors:  Tatiana Kelly da Silva Fidalgo; Matheus Melo Pithon; José Vinicius Bolognesi Maciel; Ana Maria Bolognese
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

9.  Effect of bracket bevel design and oral environmental factors on frictional resistance.

Authors:  Chen-Jung Chang; Tzer-Min Lee; Jia-Kuang Liu
Journal:  Angle Orthod       Date:  2013-04-26       Impact factor: 2.079

10.  Friction forces during sliding of various brackets for malaligned teeth: an in vitro study.

Authors:  Vito Crincoli; Letizia Perillo; Maria Beatrice Di Bisceglie; Antonio Balsamo; Vitaliano Serpico; Francesco Chiatante; Carmine Pappalettere; Antonio Boccaccio
Journal:  ScientificWorldJournal       Date:  2013-02-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.