Literature DB >> 12939775

Block regional off-resonance correction (BRORC): a fast and effective deblurring method for spiral imaging.

Hisamoto Moriguchi1, Brian M Dale, Jonathan S Lewin, Jeffrey L Duerk.   

Abstract

One primary disadvantage of spiral imaging is blurring artifact due to off-resonance effects. The conventional frequency segmented off-resonance correction method that is performed over the entire image is computationally intense due to the large number of fast Fourier transforms (FFTs) required. Here, a new fast off-resonance correction method, block regional off-resonance correction (BRORC), is presented. In this method, off-resonance correction proceeds block-by-block through the reconstructed image with FFTs performed on matrices that are smaller than the full image matrix. The BRORC algorithm is typically several times more computationally efficient than the conventional off-resonance correction algorithm. Additional computational reductions can be expected for the BRORC if only specific image regions require deblurring. The newly proposed off-resonance correction method offers significant speed advantages and equivalent image quality when compared to conventional off-resonance correction methods. Copyright 2003 Wiley-Liss, Inc.

Mesh:

Year:  2003        PMID: 12939775     DOI: 10.1002/mrm.10570

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Fast conjugate phase image reconstruction based on a Chebyshev approximation to correct for B0 field inhomogeneity and concomitant gradients.

Authors:  Weitian Chen; Christopher T Sica; Craig H Meyer
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

2.  Fast concomitant gradient field and field inhomogeneity correction for spiral cardiac imaging.

Authors:  Joseph Y Cheng; Juan M Santos; John M Pauly
Journal:  Magn Reson Med       Date:  2011-03-07       Impact factor: 4.668

3.  A simple acquisition strategy to avoid off-resonance blurring in spiral imaging with redundant spiral-in/out k-space trajectories.

Authors:  Samuel W Fielden; Craig H Meyer
Journal:  Magn Reson Med       Date:  2014-03-06       Impact factor: 4.668

4.  Typical readout durations in spiral cine DENSE yield blurred images and underestimate cardiac strains at both 3.0 T and 1.5 T.

Authors:  Gregory J Wehner; Jonathan D Suever; Samuel W Fielden; David K Powell; Sean M Hamlet; Moriel H Vandsburger; Christopher M Haggerty; Xiaodong Zhong; Brandon K Fornwalt
Journal:  Magn Reson Imaging       Date:  2018-08-10       Impact factor: 2.546

5.  Deep residual network for off-resonance artifact correction with application to pediatric body MRA with 3D cones.

Authors:  David Y Zeng; Jamil Shaikh; Signy Holmes; Ryan L Brunsing; John M Pauly; Dwight G Nishimura; Shreyas S Vasanawala; Joseph Y Cheng
Journal:  Magn Reson Med       Date:  2019-05-22       Impact factor: 4.668

6.  Application of k-space energy spectrum analysis for inherent and dynamic B0 mapping and deblurring in spiral imaging.

Authors:  Trong-Kha Truong; Nan-Kuei Chen; Allen W Song
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.