Literature DB >> 12934211

Cemented long-stem revision total knee arthroplasty.

Andrew L Whaley1, Robert T Trousdale, James A Rand, Arlen D Hanssen.   

Abstract

From 1981 to 1989, 38 cemented, posterior, stabilized, revision, total knee arthroplasties (TKAs) were performed at the authors' institution using the stemmed kinematic stabilizer prosthesis of a single design. The mean clinical follow-up after the index procedure was 10.1 years. The Knee Society pain score averaged 17 points before revision and improved to 51 points at last follow-up, and the function score averaged 48 points before revision and improved to 57 at last follow-up. Ten-year component survival free of revision or removal for any reason was 96.7%; 11-year component survival free of revision for aseptic loosening was 95.7%. Cemented stem fixation in revision TKA provides good clinical results with durable fixation at an average of 10 years' follow-up.

Entities:  

Mesh:

Year:  2003        PMID: 12934211     DOI: 10.1016/s0883-5403(03)00200-6

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  29 in total

Review 1.  Fixation of revision TKA: a review of the literature.

Authors:  J Beckmann; C Lüring; R Springorum; F X Köck; J Grifka; M Tingart
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-09-07       Impact factor: 4.342

2.  Intraoperative molds to create an articulating spacer for the infected knee arthroplasty.

Authors:  Geoffrey S Van Thiel; Keith R Berend; Gregg R Klein; Alexander C Gordon; Adolph V Lombardi; Craig J Della Valle
Journal:  Clin Orthop Relat Res       Date:  2011-04       Impact factor: 4.176

3.  Stem length in revision total knee arthroplasty.

Authors:  Anay Rajendra Patel; Brian Barlow; Amar S Ranawat
Journal:  Curr Rev Musculoskelet Med       Date:  2015-12

4.  Extent of vertical cementing as a predictive factor for radiolucency in revision total knee arthroplasty.

Authors:  Du Hyun Ro; Yool Cho; Sahnghoon Lee; Kee Yun Chung; Seong Hwan Kim; Young Min Lee; Joon Kyu Lee; Myung Chul Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-02-01       Impact factor: 4.342

5.  Modified hybrid stem fixation in revision TKA is durable at 2 to 10 years.

Authors:  Alexander P Sah; Sanjai Shukla; Craig J Della Valle; Aaron G Rosenberg; Wayne G Paprosky
Journal:  Clin Orthop Relat Res       Date:  2010-09-28       Impact factor: 4.176

6.  Results of press-fit stems in revision knee arthroplasties.

Authors:  Gavin C Wood; Douglas D R Naudie; Steven J MacDonald; Richard W McCalden; Robert B Bourne
Journal:  Clin Orthop Relat Res       Date:  2008-11-26       Impact factor: 4.176

7.  Revision total knee arthroplasty for aseptic and septic causes in patients with rheumatoid arthritis.

Authors:  Ryan M Garcia; Brian T Hardy; Matthew J Kraay; Victor M Goldberg
Journal:  Clin Orthop Relat Res       Date:  2010-01       Impact factor: 4.176

8.  Morbid Obesity: Increased Risk of Failure After Aseptic Revision TKA.

Authors:  Chad D Watts; Eric R Wagner; Matthew T Houdek; David G Lewallen; Tad M Mabry
Journal:  Clin Orthop Relat Res       Date:  2015-04-07       Impact factor: 4.176

9.  A 30-mm cemented stem extension provides adequate fixation of the tibial component in revision knee arthroplasty.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  Clin Orthop Relat Res       Date:  2015-01       Impact factor: 4.176

10.  A sliding stem in revision total knee arthroplasty provides stability and reduces stress shielding.

Authors:  Huub J Meijerink; Corné J M van Loon; Maarten C de Waal Malefijt; Albert van Kampen; Nico Verdonschot
Journal:  Acta Orthop       Date:  2010-06       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.