Literature DB >> 12930492

Effect of modern pacing algorithms on generator longevity: a predictive analysis.

Dan Gelvan1, Eugene Crystal, Barbados Dokumaci, Yuval Goldshmid, I Eli Ovsyshcher.   

Abstract

Pulse generator (PG) longevity is of major importance to the quality of care of pacemaker patients. A series of automatic algorithms affect PG longevity. This study investigated the individual and combined effects of three algorithms incorporated in the Medtronic Kappa 700 pacemaker series: Capture Management periodically measures the stimulation threshold and adjusts the PG output, Sinus Preference allows the sinus rate to prevail in a specified range below the sensor rate, and Search AV allows an extension of the AV interval if spontaneous conduction is observed. The effects of Capture Management, Sinus Preference, and Search AV on device longevity were studied in 21 consecutive patients treated in the VDD and DDDR modes. Patients were followed for 1 year. The data were analyzed using an equation provided by the manufacturer. Capture Management was activated in 20 patients. For 11 PGs at the basic settings, longevity was extended by 5.2%, whereas reprogrammed PGs had no gain. Sinus Preference was active in four DDDR patients, who gained 12.0 +/- 5.3%atrial sensing from it, with a resultant longevity gain of1.4 +/- 0.45 months(NS). Search AV was active in 19 patients and 8 responders gained 7.8 +/- 4.4 months PG longevity. The overall longevity in this study was 106.3 +/- 8.4 months with all features as programmed, whereas the longevity without Capture Management and Search AV algorithms would be 98.2 +/- 4.9 months, saving 8.1 +/- 5.8 months(range 0-18) of battery life. Thus, two algorithms: Capture Management and Search AV, have clinical relevance in the extension of PG longevity.

Entities:  

Mesh:

Year:  2003        PMID: 12930492     DOI: 10.1046/j.1460-9592.2003.t01-1-00272.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

Review 1.  Pacing technology: advances in pacing threshold management.

Authors:  Chu-pak Lau; Chung-wah Siu
Journal:  J Zhejiang Univ Sci B       Date:  2010-08       Impact factor: 3.066

2.  Algorithm for ventricular capture verification based on the mechanical evoked response.

Authors:  E Yaacoby; S Akselrod; M Eldar; M Glikson
Journal:  Med Biol Eng Comput       Date:  2005-07       Impact factor: 2.602

3.  Pacemaker longevity: the world's longest-lasting VVI pacemaker.

Authors:  David Katz; Toshio Akiyama
Journal:  Ann Noninvasive Electrocardiol       Date:  2007-07       Impact factor: 1.468

4.  A Cautionary Tale on Atrial Capture Management, Biventricular Pacing, and Recurrent Asystole.

Authors:  Christopher L Johnsrude; Kelvin C Lau
Journal:  J Innov Card Rhythm Manag       Date:  2019-10-15

5.  Hemodynamic Surveillance of Ventricular Pacing Effectiveness with the Transvalvular Impedance Sensor.

Authors:  Valeria Calvi; Giovanni Pizzimenti; Marco Lisi; Giuseppe Doria; Ludovico Vasquez; Francesco Lisi; Salvatore Felis; Donatella Tempio; Alfredo Virgilio; Alberto Barbetta; Franco Di Gregorio
Journal:  Adv Med       Date:  2014-08-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.