An in vivo comparison of two frequency-based electronic apex locators.

Aaron R Welk1, J Craig Baumgartner, J Gordon Marshall.   

Abstract

The purpose of this study was to compare the accuracy of a two-frequency (Root ZX) and a five-frequency (Endo Analyzer Model 8005) electronic apex locator under clinical conditions. Thirty-two teeth planned for extraction were used. The coronal portion of each canal was flared using Gates Glidden drills and Orifice Shapers. The canals were irrigated with 2.6% sodium hypochlorite. A K-type file was used to determine a separate working length in each canal using the electronic apex locators. The teeth were extracted and the apical 4 mm of each root canal was exposed along the long axis of the tooth. Photographic slides of each canal were projected and the file position in relation to the minor diameter was determined by two investigators. The mean distance between the electronic apex locator working length and minor diameter was 1.03 mm for the Endo Analyzer and 0.19 mm for the Root ZX. A paired sample t test showed that the Endo Analyzer had significantly longer readings beyond the minor diameter than the Root ZX (p < 0.0001). The ability to locate the minor diameter (+/- 0.5 mm) was 90.7% for the Root ZX and 34.4% for the Endo Analyzer Model 8005.

Entities:  

Mesh:

Year:  2003        PMID: 12929694     DOI: 10.1097/00004770-200308000-00002

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  11 in total

1.  Comparison of two electronic apex locators on human cadavers.

Authors:  Luca Marigo; Gian Luca Gervasi; Francesco Somma; Giuseppe Squeo; Raffaella Castagnola
Journal:  Clin Oral Investig       Date:  2015-11-04       Impact factor: 3.573

2.  Accuracy of two different apex locators in primary teeth with and without root resorption.

Authors:  Haluk Bodur; Mesut Odabaş; Ozlem Tulunoğlu; Ali Cemal Tinaz
Journal:  Clin Oral Investig       Date:  2007-11-20       Impact factor: 3.573

3.  Consistency of electronic measurements of endodontic working length when using multiple devices from the same manufacturer-an in vitro study.

Authors:  Franziska Haupt; M Hülsmann
Journal:  Clin Oral Investig       Date:  2018-03-07       Impact factor: 3.573

4.  Accuracy of five electronic foramen locators with different operating systems: an ex vivo study.

Authors:  Bruno Carvalho de Vasconcelos; Michelli de Medeiros Bueno; Suyane Maria Luna-Cruz; Marco Antonio Hungaro Duarte; Carlos Augusto de Oliveira Fernandes
Journal:  J Appl Oral Sci       Date:  2013 Mar-Apr       Impact factor: 2.698

5.  In vivo assessment of the impedance ratio method used in electronic foramen locators.

Authors:  Marcos V H Rambo; Humberto R Gamba; Gustavo B Borba; Joaquim M Maia; Carlos A S Ramos
Journal:  Biomed Eng Online       Date:  2010-09-06       Impact factor: 2.819

6.  Comparison of third generation versus fourth generation electronic apex locators in detecting apical constriction: An in vivo study.

Authors:  D V Swapna; Akash Krishna; Anand C Patil; K Rashmi; Veena S Pai; M A Ranjini
Journal:  J Conserv Dent       Date:  2015 Jul-Aug

7.  A comparative assessment of the accuracies of Raypex 5, Raypex 6, iPex and iPex II electronic apex locators: An in vitro study.

Authors:  Mugem Asli Gurel; Bagdagul Helvacioglu Kivanc; Adil Ekici
Journal:  J Istanb Univ Fac Dent       Date:  2017-01-02

8.  An Invitro Evaluation of the Accuracy of Two Electronic Apex Locators to Determine Working Length in the Presence of Various Irrigants.

Authors:  Ashwini B Prasad; Srivastava Harshit; Srivastava Arora Aastha; Raisingani Deepak
Journal:  Ethiop J Health Sci       Date:  2016-09

9.  Influence of Open Apex on Working Length Determination Using Cone-Beam Computed Tomography and Apex Locators: A Comparative In Vitro Study.

Authors:  Swati Srivastava; Hanan M Alharbi; Mai Soliman; Elzahraa Eldwakhly; Manal M Abdelhafeez
Journal:  Biomed Res Int       Date:  2022-07-23       Impact factor: 3.246

10.  Comparison of apically extruded debris associated with several nickel-titanium systems after determining working length by apex locator.

Authors:  Ersan Çiçek; Oguzhan Akkocan; Fatma Furuncuoglu
Journal:  J Conserv Dent       Date:  2016 Jan-Feb
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.