Literature DB >> 12918026

Ion release in stable hip arthroplasties using metal-on-metal articulating surfaces: a comparison between short- and medium-term results.

L Savarino1, D Granchi, G Ciapetti, E Cenni, M Greco, R Rotini, C A Veronesi, N Baldini, A Giunti.   

Abstract

The use of metallic heads articulating with metallic cups could solve the problem of polyethylene (PE) wear in total hip replacement (THR) with metal-on-PE bearings. A conspicuous release of metal ions from new models of metal-on-metal bearings has been found in the short-term, but it is yet unclear whether the medium-term corrosion rate is high or, on the contrary, it becomes negligible, because of the continuous surface finishing. Our purpose was to compare the serum ion values (nanograms per milliliter) in 15 patients with metal-on-metal stable prosthesis (Group A), in the short-term (subgroup A(1); mean follow-up: 24 mo) and medium-term (subgroup A(2); mean follow-up: 52 mo), in order to determine whether the ion release decreased with time of implant. Chromium (Cr), cobalt (Co), molybdenum (Mo) and aluminum (Al) were analyzed. Twenty-two presurgical patients were used for comparison (Group B). The reference range was obtained from a population of 27 healthy subjects (Group C). Co and Cr levels in the medium-term (subgroup A(2)) were not decreased in comparison with the short-term values (subgroup A(1)) and were significantly higher (p < 0.001) than presurgical and reference values. Otherwise, Mo and Al concentrations were not significantly increased in comparison with reference values. In conclusion, despite the apparent advantage of metal-on-metal coupling, especially in younger patient populations, there is a major concern about the extent and duration of the relevant "internal" exposure to Cr and Co ions. This exposure should be carefully monitored, in order to clarify the biologic effects of ion dissemination and, consequently, to identify risks concerning long-term toxicity of metals. Copyright 2003 Wiley Periodicals, Inc. J Biomed Mater Res 66A: 450-456, 2003

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12918026     DOI: 10.1002/jbm.a.10595

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  12 in total

1.  Improved mechanical long-term reliability of hip resurfacing prostheses by using silicon nitride.

Authors:  Wen Zhang; M Titze; B Cappi; D C Wirtz; R Telle; H Fischer
Journal:  J Mater Sci Mater Med       Date:  2010-08-20       Impact factor: 3.896

2.  Serum metal ion levels after rotating-hinge knee arthroplasty: comparison between a standard device and a megaprosthesis.

Authors:  Joerg Friesenbichler; Werner Maurer-Ertl; Patrick Sadoghi; Thomas Lovse; Reinhard Windhager; Andreas Leithner
Journal:  Int Orthop       Date:  2011-07-14       Impact factor: 3.075

Review 3.  Case report: High chromium and cobalt levels in a pregnant patient with bilateral metal-on-metal hip arthroplasties.

Authors:  Juliane Fritzsche; Cornelia Borisch; Christof Schaefer
Journal:  Clin Orthop Relat Res       Date:  2012-06-13       Impact factor: 4.176

4.  Metal-on-Metal Total Hip Resurfacing Arthroplasty: An Evidence-Based Analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2006-02-01

5.  Does ion release differ between hip resurfacing and metal-on-metal THA?

Authors:  Antonio Moroni; Lucia Savarino; Matteo Cadossi; Nicola Baldini; Sandro Giannini
Journal:  Clin Orthop Relat Res       Date:  2008-01-09       Impact factor: 4.176

Review 6.  Metal-on-Metal Bearing: Is This the End of the Line? We Do Not Think So.

Authors:  Henri Migaud; Sophie Putman; Antoine Combes; Charles Berton; Donatien Bocquet; Laurent Vasseur; Julien Girard
Journal:  HSS J       Date:  2012-09-11

Review 7.  [Particle release in metal-on-metal bearings. A risk analysis].

Authors:  C Heisel; M Thomsen; E Jakubowitz; J P Kretzer
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

8.  Metal ion levels in large-diameter total hip and resurfacing hip arthroplasty--preliminary results of a prospective five year study after two years of follow-up.

Authors:  W Maurer-Ertl; J Friesenbichler; P Sadoghi; M Pechmann; M Trennheuser; A Leithner
Journal:  BMC Musculoskelet Disord       Date:  2012-04-11       Impact factor: 2.362

9.  Significance of Elevated Blood Metal Ion Levels in Patients with Metal-on-Metal Prostheses: An Evaluation of Oxidative Stress Markers.

Authors:  Cathy Tkaczyk; Alain Petit; John Antoniou; David J Zukor; Maryam Tabrizian; Olga L Huk
Journal:  Open Orthop J       Date:  2010-07-02

Review 10.  Metal ion concentrations in body fluids after implantation of hip replacements with metal-on-metal bearing--systematic review of clinical and epidemiological studies.

Authors:  Albrecht Hartmann; Franziska Hannemann; Jörg Lützner; Andreas Seidler; Hans Drexler; Klaus-Peter Günther; Jochen Schmitt
Journal:  PLoS One       Date:  2013-08-07       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.